Analytical Sensitivity and Specificity of Four Point of Care Rapid Antigen Diagnostic Tests for SARS-CoV-2 Using Real-Time Quantitative PCR, Quantitative Droplet Digital PCR, and a Mass Spectrometric Antigen Assay as Comparator Methods
Abstract Background We evaluated the analytical sensitivity and specificity of 4 rapid antigen diagnostic tests (Ag RDTs) for severe acute respiratory syndrome coronavirus 2, using reverse transcription quantitative PCR (RT-qPCR) as the reference method and further characterizing samples using droplet digital quantitative PCR (ddPCR) and a mass spectrometric antigen test. Methods Three hundred fifty (150 negative and 200 RT-qPCR positive) residual PBS samples were tested for antigen using the BD Veritor lateral flow (LF), ACON LF, ACON fluorescence immunoassay (FIA), and LumiraDx FIA. ddPCR was performed on RT-qPCR–positive samples to quantitate the viral load in copies/mL applied to each Ag RDT. Mass spectrometric antigen testing was performed on PBS samples to obtain a set of RT-qPCR–positive, antigen-positive samples for further analysis. Results All Ag RDTs had nearly 100% specificity compared to RT-qPCR. Overall analytical sensitivity varied from 66.5% to 88.3%. All methods detected antigen in samples with viral load >1 500 000 copies/mL RNA, and detected ≥75% of samples with viral load of 500 000 to 1 500 000 copies/mL. The BD Veritor LF detected only 25% of samples with viral load between 50 000 to 500 000 copies/mL, compared to 75% for the ACON LF device and >80% for LumiraDx and ACON FIA. The ACON FIA detected significantly more samples with viral load <50 000 copies/mL compared to the BD Veritor. Among samples with detectable antigen and viral load <50 000 copies/mL, sensitivity of the Ag RDT varied between 13.0% (BD Veritor) and 78.3% (ACON FIA). Conclusions Ag RDTs differ significantly in analytical sensitivity, particularly at viral load <500 000 copies/mL.
The Pitfalls of Using Research Grade Immunoassays for Thyroid Health Measurements
Journal of the Endocrine Society | May 3, 2021 | Volume: 5 | Issue: Supplement_1 | Pages: A834-A834
Abstract Introduction: Immunoassay technology is subject to matrix interferences that can produce inaccurate results and incorrect conclusions when using samples not previously validated. While many commercially available research grade (RG) immunoassay kits are available, caution should be applied when using RG kits for thyroid health assessments, particularly on samples from pregnant individuals whose blood chemistry is unique to non-pregnant individuals. Question: Do RG immunoassay kits reliably provide precise and accurate measurements of thyroid health biomarkers in serum Standard Reference Materials (SRMs) from pregnant and non-pregnant donors? Methods: T4, T3, rT3, Tg and TSH measurements were conducted on SRMs 971, Hormones in Frozen Human Serum, and SRM 1949, Frozen Prenatal Serum, using RG immunoassay kits. When available, performance was assessed against validated FDA approved immunoassays or mass spectrometric (MS) methods. Results: RG kits were variable, inaccurate, or imprecise for four of the six biomarkers assessed. RG kit total thyroid hormone measurements overall performed comparably to MS methods, except rT3 measurements, which were twofold greater than mass spectrometric measurements (971M RG mean = 0.51 ng/mL, MS mean = 0.20 ng/mL, p < 0.0001; 971F RG = 0.48 ng/mL, MS = 0.18 ng/mL, p < 0.0001) and had CVs over 30 %. RG kit Tg measurements varied sometimes by as much as tenfold (971M means of 6.50 ng/mL up to 63.3 ng/mL, p < 0.0001; 971F means of 0.350 ng/mL up to 14.5 mg/mL, p < 0.0001). TSH values differed by RG kit manufacturer (971M means of 1.27 µIU/mL up to 1.82 µIU/mL, p < 0.0001; 971F means of 1.36 µIU/mL up to 2.27 µIU/mL, p < 0.0001) and by dilution scheme using the same manufacturer with one case indicating a diagnosis of hypothyroid versus normal TSH levels (1949 non-pregnant undiluted mean = 2325 pg/mL, half dilution mean = 1631 pg/mL, p < 0.0001). Conclusions: RG immunoassays are often used for research projects because they do not require expensive equipment and are simple to conducted. However, we demonstrate here that not all kits are accurate for all patient samples. By utilizing a matrix matched SRM with well-defined quantities of thyroid health biomarkers, one can assess method accuracy, making measurements from different methods comparable. Thereby, data can be harmonized to contribute reliable data on thyroid biomarkers to advance the field of thyroid health.
Urinary Steroid Metabolome Signature Is Associated With Pre-Frailty and Frailty Phenotype in Older Adults
Journal of the Endocrine Society | May 3, 2021 | Volume: 5 | Issue: Supplement_1 | Pages: A101-A101
Abstract Background: Frailty is characterized by an increased vulnerability and a decline in physiological reserve. Frailty has been previously linked to cortisol concentrations and blunted diurnal cortisol secretion. Our objective was to determine the association of urine steroid metabolome and its diurnal variation with frailty and prefrailty in older adults. Methods: Cross-sectional study of community-dwelling adults ≥ 50 years. Participants with adrenal disorders, end-stage renal or liver disease, on exogenous steroids or drugs affecting steroid metabolism were excluded. All participants completed day and night separate urine collection. Frailty was assessed using a phenotype model (weight loss, exhaustion, grip strength, low physical activity, and slow walking pace). Participants were characterized as frail if they met at least three criteria, pre-frail if they fulfilled one or two criteria, and robust if no criteria were met. Urine samples were analyzed with the liquid-chromatography, high-resolution, accurate-mass mass spectrometry for 25 urine steroid metabolites. Results: Of 119 participants, 60 (50.4%) were women, without sex differences in age or education status. On frailty assessment, 5 (4.2%) participants were frail and 33 (27.7%) were prefrail, with equal sex distribution. Urine steroid metabolome analysis demonstrated 21/25 steroids were higher in men vs women. In an age adjusted model, presence of prefrailty or frailty was associated with a higher ratio of total cortisol metabolites/total androgen metabolites (TCM/TAM) in men (estimate 0.64, P-value= 0.0004), but not in women. In men, after adjusting for age, among cortisol metabolites, lower day to night ratio of 5α-Tetrahydrocortisol (estimate -0.36, P-value= 0.0419) and β-Cortol (estimate -0.35, P-value= 0.0238) were associated with frail or prefrail phenotype. After adjusting for age, higher ratio of TCM/TAM was associated lower gait speed in men (estimate -1.2, P-value= 0.046) and women (estimate -3.9, P-value= 0.012); and lower hand grip strength in men (estimate -0.04, P-value= 0.046) but not in women. Conclusion: We showed that a higher glucocorticoid to androgen ratio and a flattened circadian steroid variation were associated with presence of frail or prefrail phenotype in men. Further studies should examine the role of steroid metabolism and HPA axis impairment, and the associated sex differences, in the functional decline in aging population.
Urinary Steroid Metabolome Signature is Associated With Cognitive Function in Older Adults
Journal of the Endocrine Society | May 3, 2021 | Volume: 5 | Issue: Supplement_1 | Pages: A100-A101
Abstract Background: Elevated urine cortisol (<1% of urinary steroid metabolome) was reported to predict future development of dementia. Our objective was to determine the association of urine steroid metabolome and its diurnal variation with cognitive function in men and women. Methods: Cross-sectional study of community-dwelling adults ≥ 50 years. Participants with adrenal disorders, end-stage renal or liver disease, on exogenous steroids or drugs affecting steroid metabolism were excluded. All participants completed day and night separate urine collection. A series of seven IPad-based tests using the National Institute of Health Toolbox Cognition Battery were administered to evaluate five key domains; performance was reported using fully corrected T-scores for age, sex, education, and race with a national normative mean of 50. T-scores were generated for the two summary measures: 1) fluid cognition (includes executive function, episodic memory, working memory, and processing speed), and 2) total composite (composite of fluid and language score). Urine samples were analyzed with the liquid-chromatography, high-resolution, accurate-mass mass spectrometry for 25 urine steroid metabolites. Results: Of 109 participants, 56 (51%) were women, and age and educational status were similar in men and women. On cognitive assessment, men and women had similar median composite cognition (T-score of 53 vs 54, p=0.74) and fluid cognition (T-score of 53 vs 51, p-value 0.96). Urine steroid metabolome analysis demonstrated 21/25 steroids were higher in men vs women. In both women and men, the ratio of total cortisol metabolites/total androgen metabolites (TCM/TAM) was associated with lower fluid cognition (women: ρ= -0.34, p=0.01, men: ρ= -0.43, p=0.001) and composite cognition (women: ρ= -0.27, p=0.04, men: ρ= -0.39, p=0.004). Higher ratio of day to night TCM were associated with a better fluid cognition in men (ρ= 0.35, p=0.01), but not in women (ρ= -0.11, p=0.41). Steroid ratios suggesting a relative enzymatic deficiency of 5α-Reductase type 2 was associated with lower fluid cognition in women (ρ= -0.29, p=0.03). In men, the fluid composite score was associated with a relative deficiency in 21-Hydroxylase (ρ= 0.42, p=0.002), 3β-Hydroxysteroid dehydrogenase (ρ= 0.43, p=0.001), and P450oxidoreductase (ρ= -0.35, p=0.01). Conclusion: We showed that a higher glucocorticoid to androgen ratio and a flattened circadian steroid variation were associated with lower global and fluid cognition score. Steroid ratios reflecting steroidogenesis enzymatic activity demonstrated sex differences in relation to cognition. Additional studies should examine whether the steroid fingerprint associated with lower cognition is predictive of a future dementia onset.
Development of a pregnancy-specific reference material for thyroid biomarkers, vitamin D, and nutritional trace elements in serum
Clinical Chemistry and Laboratory Medicine (CCLM) | November 3, 2020 | Volume: 59 | Issue: 4 | Pages: 671-679
AbstractObjectivesMatrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy.MethodsSerum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only).ResultsCertified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003).TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS.ConclusionsThe analyte concentrations’ changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.
MON-169 Diagnostic Utility of Free Cortisol in Dexamethasone Suppression Test. A Prospective Study in Healthy Subjects
Journal of the Endocrine Society | May 8, 2020 | Volume: 4 | Issue: Supplement_1 | Pages: No page available
Abstract OBJECTIVE: Low dose dexamethasone suppression testing (DST) is standard of care in patients with adrenal incidentalomas or suspected endogenous hypercortisolism. False positive total serum cortisol (TC) results occur due to poor absorption, rapid metabolism or estrogen use. Free serum cortisol (FC) measurement is an alternative, but optimal cut-offs are unknown. We aimed to establish the optimal serum dexamethasone concentrations (DEXA) to interpret TC and FC results and identify reasons for discrepancies between TC and FC values in healthy male and female (with and without oral contraceptive therapy, OCT) subjects. METHODS: Single center prospective study of healthy subjects >17 years old undergoing assessment with DST between 2016 and 2019. Measurement of FC and DEXA was performed by tandem mass spectrometry and TC by immune-enzymatic assay at 8 AM following overnight administration of 1 mg dexamethasone at 11pm. Subjects were excluded if they had a known adrenal adenoma, any form of endogenous cortisol excess, or exogenous steroid use. RESULTS: DST was performed in 165 healthy volunteers, median age of 29.5 (18-74) years; 53 men (32%) and 112 (67%) women, median BMI 25 (18-42) kg/m2, 47 (42%) of which were taking OCT (median daily ethinyl-estradiol dose of 30 (20-35) mcg). The median DEXA was 0.34 (0.09-1.12) mcg/dl, median TC was 0.8 (0.25-15.7) mcg/dl and median FC was 24 (4-714) ng/ml. TC and FC measurements were highly correlated (r2=0.89, p<0.0001). The median FC/TC was 3% (0.3-6.7), lowest in women on OCT (median 2.5% vs 3.3% in women not on OCT and men, p<0.0001). TC>1.8 mcg/dl was demonstrated in 18 (11%) healthy subjects (men: 3/53, 5.7% vs women not on OCT: 3/65, 4.6% and women on OCT: 12/47, 25.5%, p=0.0007). Excluding women on OCT, the proportion of subjects with TC>1.8 was higher when DEXA was <0.2mcg/dl (4/15, 27%) vs when DEXA was >0.2mcg/dl (2/101, 2%),(p<0.0001). After excluding 24 (14%) healthy subjects with DEXA <0.2 mcg/dl, in the remaining 142 subjects (51 (35%) men, 54 (38%) women not on OCT and 39 (27%) women on OCT), median TC was 0.75 (0.25-4.6) mcg/dl and median FC was 23 (4-103) ng/ml). Significant differences were noted in both TC and FC following DST within subgroups: men vs women not on OCT vs women on OCT, TC: 0.6 vs 0.7 vs 1.3 mcg/dl, (p<0.0001) and FC: median 20 vs 22 vs 31 ng/ml, (p<0.0001). All men and all women not on OCT demonstrated post-DST FC <50 ng/ml (97.5% cutoff of 47 and 37), while women on OCT demonstrated post-DST FC <50 in 80% and FC<75 in 95%. CONCLUSION: Post-DST TC>1.8 mcg/dl was demonstrated in 11% of all healthy subjects, of which 1 in 4 were women on OCT and 1 in 4 had DEXA<0.2 mcg/dl. Simultaneous measurement of serum DEXA during DST may be valuable when false positive results are suspected. Despite a lower FC/TC ratio in women on OCT, post-DST FC cutoffs were higher in women on OCT. Measurement of FC after DST may be helpful in some but not all women on OCT.
Commentary on Cryptogenic Cushing Syndrome Due to a White Lie
AbstractBACKGROUNDDroplet digital PCR (ddPCR) is an emerging technology for quantitative cell-free DNA oncology applications. However, assay performance criteria must be established in a standardized manner to harness this potential. We reasoned that standard protocols used in clinical chemistry assay validation should be able to fill this need.METHODSWe validated KRAS, EGFR, and BRAF quantitative ddPCR assays based on the Clinical Laboratory Improvement Act regulations for laboratory-developed tests in clinical chemistry and the matching Clinical and Laboratory Standards Institute guidelines. This included evaluation of limit of the blank (LOB), limit of detection (LOD), limit of quantification (LOQ), intraassay and interassay imprecision, analytical range, dilution linearity, accuracy (including comparison with orthogonal platforms), reference range study, interference, and stability studies.RESULTSFor the ddPCR assays, the LOB was 4 mutant copies, LODs were 12 to 22 copies, and LOQs were 35 to 64 copies. The upper limit of the dynamic range was 30000 copies, and dilutions were linear down to the LOQs with good accuracy of spike recovery of Horizon reference material. Method comparisons with next-generation sequencing and an alternative ddPCR platform showed complete qualitative agreement and quantitative concordance, with slopes of 0.73 to 0.97 and R2s of 0.83 to 0.99. No substantial interferences were discovered. Wild-type copy numbers in plasma ranged from 462 to 6169/mL in healthy individuals.CONCLUSIONSStandard clinical chemistry assay validation protocols can be applied to quantitative ddPCR assays. This should facilitate comparison of the performance of different assays and allow establishment of minimal significant change thresholds in monitoring applications.
Clinical Validation of a Haplotyping Method with Next-Generation Sequencing