Citations 42

False Lumen Embolization to Treat Disseminated Intravascular Coagulation After Thoracic Endovascular Aortic Repair of Type B Aortic Dissection

Journal of Endovascular Therapy | November 19, 2015 | Volume: 22 | Issue: 6 | Pages: 938-941

10.1177/1526602815607185 | PMID 26384395

Purpose: To present a rare case of disseminated intravascular coagulation (DIC) after thoracic endovascular aortic repair (TEVAR) and its novel treatment. Case Report: A 55-year-old man presented with DIC 10 months after TEVAR for chronic type B aortic dissection and descending thoracic aortic aneurysm. He had persistent retrograde flow in the false lumen with a stable aneurysm diameter. The false lumen was embolized with multiple Amplatzer plugs, which promoted false lumen thrombosis. Laboratory evaluation on postoperative day 7 demonstrated resolution of the coagulopathy. Follow-up at 18 months revealed no recurrent DIC; computed tomography angiography showed a stable aortic diameter and excluded thoracic aneurysm sac. Conclusion: This case demonstrates an unusual, potentially fatal postoperative complication of endovascular treatment of type B aortic dissections successfully treated with an innovative endovascular solution.
Endovascular Repair of Aortic Coarctation Pseudoaneurysm Using an Off-Label “Hourglass” Stent-Graft Configuration

Journal of Endovascular Therapy | May 19, 2015 | Volume: 22 | Issue: 3 | Pages: 460-465

10.1177/1526602815581595 | PMID 25878022

Purpose: To describe an endovascular technique for treating a pseudoaneurysm of the thoracic aorta using an off-label “hourglass” stent-graft configuration. Case Report: A 68-year-old patient with prior open thoracic aorta coarctation repair presented with recurrent coarctation and concurrent enlarging 6-cm bilobed pseudoaneurysm involving the previous anastomosis. There was significant discrepancy in the aortic diameter (measured from wall to wall) proximal to the coarctation (14 mm), at the narrowest segment (8 mm), and distally (23 mm). Endovascular repair included deployment of an inverted iliac limb proximally, followed by an inverted aortic converter distally, giving an “hourglass” configuration. There were no perioperative or stent-graft–related complications at 5-year follow-up. The aneurysm regressed from 61 to 25 mm. Conclusion: The use of inverted stent-grafts can allow tapering and flaring to adapt to discrepant aortic diameters. This technique may be useful in select patients with prior coarctation repair who do not need excessive dilation of the narrow aortic segment.