Citations 4

Evaluation of automated airway morphological quantification for assessing fibrosing lung disease

Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization | March 31, 2024 | Volume: 12 | Issue: 1 | Pages: No page available

10.1080/21681163.2024.2325361

Consistency of Automated Quantitation of Pulmonary Parenchymal Patterns on Normal, Low and Ultra-Low Dose CT

C22. ILD: DIAGNOSIS | August 26, 2019 | Volume: No volume available | Issue: No issue available | Pages: A4313-A4313

10.1164/ajrccm-conference.2019.199.1_meetingabstracts.a4313

Risk factors for pleural effusion recurrence in patients with malignancy

Respirology | July 2, 2018 | Volume: 24 | Issue: 1 | Pages: 76-82

10.1111/resp.13362 | PMID 29966171

ABSTRACTBackground and objectiveThe main purpose of treatment in patients with malignant pleural effusion (MPE) is symptom palliation. Currently, patients undergo repeat thoracenteses prior to receiving a definitive procedure as clinicians are not aware of the risk factors associated with fluid recurrence. The primary objective of this study was to identify risk factors associated with recurrent symptomatic MPE.MethodsRetrospective multicentre cohort study of patients who underwent first thoracentesis was performed. The primary outcome was time to fluid recurrence requiring intervention in patients with evidence of metastatic disease. We used a cause‐specific hazard model to identify risk factors associated with fluid recurrence. We also developed a predictive model, utilizing Fine–Gray subdistribution hazard model, and externally validated the model.ResultsA total of 988 patients with diagnosed metastatic disease were included. Cumulative incidence of recurrence was high with 30% of patients recurring by day 15. On multivariate analysis, size of the effusion on chest X‐ray (up to the top of the cardiac silhouette (hazard ratio (HR): 1.84, 95% CI: 1.21–2.80, P = 0.004) and above the cardiac silhouette (HR: 2.22, 95% CI: 1.43–3.46, P = 0.0004)), larger amount of pleural fluid drained (HR: 1.06, 95% CI: 1.04–1.07, P < 0.0001) and higher pleural fluid LDH (HR: 1.008, 95% CI: 1.004–1.011, P < 0.0001) were associated with increased hazard of recurrence. Negative cytology (HR: 0.52, 95% CI: 0.43–0.64, P < 0.0001) was associated with decreased hazard of recurrence. The model had low prediction accuracy.ConclusionPleural effusion size, amount of pleural fluid drained, LDH and pleural fluid cytology were found to be risk factors for recurrence.
Chlorhexidine Bathing Impact on Infections, Effect of Etomidate on Sepsis Mortality, and Evaluation of Ventilator-associated Conditions

American Journal of Respiratory and Critical Care Medicine | May 15, 2015 | Volume: 191 | Issue: 10 | Pages: 1197-1199

10.1164/rccm.201503-0435rr | PMID 25978572