Back to Authors

Katzmann, Jerry A.

A5111767341 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 90

Immunoglobulin free light chain ratio is an independent risk factor for progression of smoldering (asymptomatic) multiple myeloma

Blood | October 17, 2007 | Volume: 111 | Issue: 2 | Pages: 785-789

10.1182/blood-2007-08-108357 | PMID 17942755

We hypothesized that increased monoclonal free kappa or lambda immunoglobulin light chains in smoldering multiple myeloma (SMM), as detected by the serum free light chain (FLC) assay, indicates an increased risk of progression to active myeloma. Baseline serum samples obtained within 30 days of diagnosis were available in 273 patients with SMM seen from 1970 to 1995. At a median follow-up of surviving patients of 12.4 years, transformation to active disease has occurred in 59%. The best breakpoint for predicting risk of progression was an FLC ratio of 0.125 or less, or 8 or more (hazard ratio, 2.3; 95% CI, 1.6-3.2). The extent of abnormality of FLC ratio was independent of SMM risk categories defined by number of bone marrow plasma cells (BMPCs) and size of serum M proteins (BMPC ≥ 10% and serum M protein ≥ 3 g/dL; BMPC ≥ 10% but serum M protein < 3 g/dL; and serum M protein≥ 3 g/dL but BMPC < 10%). Incorporating the FLC ratio into the risk model, the 5-year progression rates in high-, intermediate-, and low-risk groups were 76%, 51%, and 25%, respectively. The serum immunoglobulin FLC ratio is an important additional determinant of clinical outcome in patients with SMM.
Comparison of Bromcresol Green and Agarose Protein Electrophoresis for Quantitation of Serum Albumin in Multiple Myeloma

Clinical Chemistry | April 26, 2007 | Volume: 53 | Issue: 6 | Pages: 1099-1103

10.1373/clinchem.2007.088252 | PMID 17463172

Abstract Background: The International Staging System for multiple myeloma has increased the importance of accurate measurement of serum albumin. Two common albumin assays, bromcresol green (BCG) and agarose gel protein electrophoresis (PEL), frequently yield discordant results, creating confusion regarding which assay is superior for use in myeloma. Methods: We measured albumin by BCG on a Roche Modular system, by PEL with a Helena SPIFE SPE Vis agarose gel, and by immunonephelometry performed on a Dade Behring BNII nephelometer. BCG and PEL were used to measure albumin in 5777 patient samples, and all 3 methods were used in an additional 252 samples. The clinical impact was assessed on 698 myeloma patient samples. Results: For sera with zero/low monoclonal immunoglobulin protein (M)-spike (0 to &lt;15 g/L), results for both BCG and PEL correlated well to nephelometry, although median PEL results were 8 g/L lower than corresponding BCG measurements. Correlation between PEL and nephelometry or BCG diminished with increasing M-spike, with PEL eventually overestimating albumin compared with both other assays. IgG and IgA M-spikes showed significantly different effects on albumin discordance. For 35% of myeloma patients, discrepancy between BCG and PEL had a potentially clinically significant effect on staging, but no difference in group survival was found. Conclusions: Both BCG and PEL correlate well to nephelometry in sera with zero/low M-spikes. In the presence of larger M-spikes, PEL correlates poorly to nephelometry or BCG, whereas BCG compares well with nephelometry regardless of M-spike. Thus, albumin measurement can be performed reliably in myeloma patient sera by use of inexpensive, automated BCG assays.
Diagnosis of α-1-Antitrypsin Deficiency: An Algorithm of Quantification, Genotyping, and Phenotyping

Clinical Chemistry | October 20, 2006 | Volume: 52 | Issue: 12 | Pages: 2236-2242

10.1373/clinchem.2006.072991 | PMID 17053153

AbstractBackground: Laboratory testing in suspected α-1-antitrypsin (A1AT) deficiency involves analysis of A1AT concentrations and identification of specific alleles by genotyping or phenotyping. The purpose of this study was to define and evaluate a strategy that provides reliable laboratory evaluation of A1AT deficiency.Methods: Samples from 512 individuals referred for A1AT phenotype analysis were analyzed by quantification, phenotype, and genotype. A1AT concentrations were measured by nephelometry. Phenotype analysis was performed by isoelectric focusing electrophoresis. The genotype assay detected the S and Z deficiency alleles by a melting curve analysis.Results: Of the 512 samples analyzed, 2% of the phenotype and genotype results were discordant. Among these 10 discordant results, 7 were attributed to phenotyping errors. On the basis of these data we formulated an algorithm, according to which we analyzed samples by genotyping and quantification assays, with a reflex to phenotyping when the genotype and quantification results were not concordant. Retrospective analyses demonstrated that 4% of samples submitted for genotype and quantitative analysis were reflexed to phenotyping. Of the reflexed samples, phenotyping confirmed the genotype result in 85% of cases. In the remaining 15%, phenotyping provided further information, including identifying rare deficiency alleles and suggesting the presence of a null allele, and allowed for a more definitive interpretation of the genotype result.Conclusions: The combination of genotyping and quantification, with a reflex to phenotyping, is the optimal strategy for the laboratory evaluation of A1AT deficiency.
Serum Free Light Chain Specificity and Sensitivity: A Reality Check

Clinical Chemistry | August 29, 2006 | Volume: 52 | Issue: 9 | Pages: 1638-1639

10.1373/clinchem.2006.072041 | PMID 16940461

Bence Jones Cryoglobulinuria: Characterization of a Urinary κ Light Chain Cryoglobulin

Clinical Chemistry | June 23, 2006 | Volume: 52 | Issue: 7 | Pages: 1435-1436

10.1373/clinchem.2006.066753 | PMID 16798972

Immunoglobulin free light chains and solitary plasmacytoma of bone

Blood | June 1, 2006 | Volume: 108 | Issue: 6 | Pages: 1979-1983

10.1182/blood-2006-04-015784 | PMID 16741249

Abstract An abnormal serum immunoglobulin free light chain (FLC) ratio at diagnosis may identify risk of progression to myeloma in patients with solitary bone plasmacytoma (SBP). In the cohort of 116 patients, 43 have progressed to myeloma, with a median time to progression of 1.8 years. The FLC ratio was determined in all 116 patients on serum collected at time of diagnosis and was abnormal in 54 patients (47%). An abnormal FLC ratio was associated with a higher risk of progression to myeloma (P = .039). The risk of progression at 5 years was 44% in patients with an abnormal serum FLC ratio at diagnosis compared with 26% in those with a normal FLC ratio. One to 2 years following diagnosis, a persistent serum M protein level of 5 g/L (0.5 g/dL) or higher was an additional risk factor for progression. A risk stratification model was constructed using the 2 variables of FLC ratio and M protein level: patients with a normal FLC ratio at baseline and M protein level less than 5 g/L (0.5 g/dL) at 1 to 2 years following diagnosis (low risk, n = 31); with either risk factor abnormal (intermediate risk, n = 26); and with both an abnormal FLC ratio and M protein level of 5 g/L (0.5 g/dL) or higher (high risk, n = 18). The corresponding progression rates at 5 years were significantly different in the low, intermediate, and high groups: 13%, 26%, and 62%, respectively (P < .001).
Absolute values of immunoglobulin free light chains are prognostic in patients with primary systemic amyloidosis undergoing peripheral blood stem cell transplantation

Blood | January 6, 2006 | Volume: 107 | Issue: 8 | Pages: 3378-3383

10.1182/blood-2005-07-2922 | PMID 16397135

AbstractThe immunoglobulin free light chain (FLC) is the precursor protein of amyloid in primary systemic amyloidosis (AL). Historically, the ability to monitor the amyloid protein precursor protein has been crude. We evaluated the utility of the FLC assay in a retrospective analysis of patients with AL undergoing peripheral blood stem cell transplantation (PBSCT). Ninety-three such patients had serial FLC measurements performed. The prognostic effects of the initial concentration and the extent of reduction of monoclonal FLC on survival were studied. There was a significantly higher risk of death in patients with higher baseline FLC (hazard ratio 2.6, P < .04). Baseline FLC correlated with serum cardiac troponin levels, and higher FLC levels were associated with more organs involved by amyloid, suggesting that high FLC levels may be associated with more advanced disease. The percent FLC reduction did not predict for survival, but the absolute level of FLC achieved after therapy did. Normalization of FLC level after PBSCT predicted for both organ response and complete hematologic response. Achievement of FLC response was a better predictor of survival than achievement of complete hematologic response or normalization of the FLC ratio. FLC measurements both before and after PBSCT are important predictors of patient outcome.
Serum free light chain ratio is an independent risk factor for progression in monoclonal gammopathy of undetermined significance

Blood | April 26, 2005 | Volume: 106 | Issue: 3 | Pages: 812-817

10.1182/blood-2005-03-1038 | PMID 15855274

Abstract We hypothesized that the presence of monoclonal free kappa or lambda immunoglobulin light chains in monoclonal gammopathy of undetermined significance (MGUS), as detected by the serum free light chain (FLC) assay increases the risk of progression to malignancy. Of 1384 patients with MGUS from Southeastern Minnesota seen at the Mayo Clinic from 1960 to 1994, baseline serum samples obtained within 30 days of diagnosis were available in 1148. At a median follow-up of 15 years, malignant progression had occurred in 87 (7.6%) patients. An abnormal FLC ratio (kappa-lambda ratio &lt; 0.26 or &gt; 1.65) was detected in 379 (33%) patients. The risk of progression in patients with an abnormal FLC ratio was significantly higher compared with patients with a normal ratio (hazard ratio, 3.5; 95% confidence interval [CI], 2.3-5.5; P &lt; .001) and was independent of the size and type of the serum monoclonal (M) protein. Patients with an abnormal serum FLC ratio, non–immunoglobulin G (non-IgG) MGUS, and a high serum M protein level (≥ 15 g/L) had a risk of progression at 20 years of 58% (high-risk MGUS) versus 37% with any 2 of these risk factors (high-intermediate risk), 21% with one risk factor (low-intermediate risk), and 5% when none of the risk factors were present (low risk).
Diagnostic Performance of Quantitative κ and λ Free Light Chain Assays in Clinical Practice

Clinical Chemistry | March 18, 2005 | Volume: 51 | Issue: 5 | Pages: 878-881

10.1373/clinchem.2004.046870 | PMID 15774572

Abstract Background: The quantitative assay for free light chains (FLCs) is a recently introduced commercial test reported to be sensitive and specific for detecting FLC diseases such as primary systemic amyloidosis (AL), light chain deposition disease (LCDD), nonsecretory multiple myeloma (NSMM), and light chain multiple myeloma. We evaluated its diagnostic performance in clinical practice. Methods: All FLC clinical test results generated in 2003 were abstracted from the Laboratory Information System. Diagnoses were obtained from the Dysproteinemia database and the patient medical history. Results: In 2003, we received samples for FLC assays from 1020 Mayo Clinic patients. The majority of these patients (88%) had bone marrow-derived monoclonal plasma cell disorders (PCDs). The 121 patients who did not have monoclonal gammopathy all had FLC κ/λ ratios within the range of values obtained for a reference population in our laboratory. Among the patients with monoclonal gammopathies were patients with multiple myeloma (330), AL (269), monoclonal gammopathy of undetermined significance (114), smoldering multiple myeloma (72), plasmacytoma (22), NSMM (20), macroglobulinemia (9), LCDD (7), and a variety of other PCDs. Among the 110 AL patients who had not been previously treated and who had a FLC assay performed within 120 days of diagnosis, the FLC κ/λ ratio was positive in 91% compared with 69% for serum immunofixation electrophoresis (IFE) and 83% for urine IFE. The combination of serum IFE and serum FLC assay detected an abnormal result in 99% (109 of 110) of patients with AL. Conclusion: The performance of the FLC assay in this analysis of clinical laboratory data is consistent with results from published retrospective validation studies.
Cerebrospinal Fluid Leakage: Agarose Gel Electrophoresis Detection of β2-Transferrin and Nephelometric Quantification of β-Trace Protein

Clinical Chemistry | September 30, 2004 | Volume: 50 | Issue: 12 | Pages: 2401-2403

10.1373/clinchem.2004.040246 | PMID 15459095