Back to Authors

Pleskow, Douglas K.

https://orcid.org/0000-0003-0092-9496

A5005641244 | I1316535847

Mayo Clinic

Beth Israel Deaconess Medical Center

Citations 23

Global prospective case series of ERCPs using a single-use duodenoscope

Endoscopy | July 18, 2023 | Volume: 55 | Issue: 12 | Pages: 1103-1114

10.1055/a-2131-7180 | PMID 37463599

Background The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. Methods 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). Results Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3–4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. Conclusions In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.
A Delphi Method for Development of a Barrett’s Esophagus Question Prompt List as a Communication Tool for Optimal Patient-physician Communication

Journal of Clinical Gastroenterology | February 8, 2023 | Volume: 58 | Issue: 2 | Pages: 131-135

10.1097/mcg.0000000000001832 | PMID 36753462

Background Methods: The question prompt list content was derived through a modified Delphi process consisting of 3 rounds. In round 1, experts provided 5 answers to the prompts “What general questions should patients ask when given a new diagnosis of Barrett’s esophagus” and “What questions do I not hear patients asking, but given my expertise, I believe they should be asking?” Questions were reviewed and categorized into themes. In round 2, experts rated questions on a 5-point Likert scale. In round 3, experts rerated questions modified or reduced after the previous rounds. Only questions rated as “essential” or “important” were included in Barrett’s esophagus question prompt list (BE-QPL). To improve usability, questions were reduced to minimize redundancy and simplified to use language at an eighth-grade level (Fig. 1). Results: Twenty-one esophageal medical and surgical experts participated in both rounds (91% males; median age 52 years). The expert panel comprised of 33% esophagologists, 24% foregut surgeons, and 24% advanced endoscopists, with a median of 15 years in clinical practice. Most (81%), worked in an academic tertiary referral hospital. In this 3-round Delphi technique, 220 questions were proposed in round 1, 122 (55.5%) were accepted into the BE-QPL and reduced down to 76 questions (round 2), and 67 questions (round 3). These 67 questions reached a Flesch Reading Ease of 68.8, interpreted as easily understood by 13 to 15 years olds. Conclusions: With multidisciplinary input, we have developed a physician-derived BE-QPL to optimize patient-physician communication. Future directions will seek patient feedback to distill the questions further to a smaller number and then assess their usability.
First interobserver agreement of optical coherence tomography in the bile duct: A multicenter collaborative study

Endoscopy International Open | March 23, 2022 | Volume: 10 | Issue: 08 | Pages: E1065-E1072

10.1055/a-1779-5027 | PMID 35979031

Abstract Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.
Clinical Validation Of Acer, GSSED-RE, GSSED-RE2 Scores For Prediction Of Delayed Bleeding After Endoscopic Mucosal Resection Of Large Colorectal Lesions

Endoscopy | March 31, 2021 | Volume: 53 | Issue: No issue available | Pages: No page available

10.1055/s-0041-1724467

Factors associated with complete clip closure after endoscopic mucosal resection of large colorectal polyps

Endoscopy | December 9, 2020 | Volume: 53 | Issue: 11 | Pages: 1150-1159

10.1055/a-1332-6727 | PMID 33291159

Abstract Background and study aim Delayed bleeding is a common adverse event following endoscopic mucosal resection (EMR) of large colorectal polyps. Prophylactic clip closure of the mucosal defect after EMR of nonpedunculated polyps larger than 20 mm reduces the incidence of severe delayed bleeding, especially in proximal polyps. This study aimed to evaluate factors associated with complete prophylactic clip closure of the mucosal defect after EMR of large polyps. Methods This is a post hoc analysis of the CLIP study (NCT01936948). All patients randomized to the clip group were included. Main outcome was complete clip closure of the mucosal resection defect. The defect was considered completely closed when no remaining mucosal defect was visible and clips were less than 1 cm apart. Factors associated with complete closure were evaluated in multivariable analysis. Results In total, 458 patients (age 65, 58 % men) with 494 large polyps were included. Complete clip closure of the resection defect was achieved for 338 polyps (68.4 %); closure was not complete for 156 (31.6 %). Factors associated with complete closure in adjusted analysis were smaller polyp size (odds ratio 1.06 for every millimeter decrease [95 % confidence interval 1.02–1.08]), good access (OR 3.58 [1.94–9.59]), complete submucosal lifting (OR 2.28 [1.36–3.90]), en bloc resection (OR 5.75 [1.48–22.39]), and serrated histology (OR 2.74 [1.35–5.56]). Conclusions Complete clip closure was not achieved for almost one in three resected large nonpedunculated polyps. While stable access and en bloc resection facilitate clip closure, most factors associated with clip closure are not modifiable. This highlights the need for alternative closure options and measures to prevent bleeding.
Fine-needle aspiration of pancreatic cystic lesions: a randomized study with long-term follow-up comparing standard and flexible needles

Endoscopy | November 16, 2020 | Volume: 53 | Issue: 11 | Pages: 1132-1140

10.1055/a-1311-9927 | PMID 33197941

Abstract Background Pancreatic cystic lesions (PCLs) are increasingly found on cross-sectional imaging, with the majority having a low risk for malignancy. The added value of fine-needle aspiration (FNA) in risk stratification remains unclear. We evaluated the impact of three FNA needles on diagnostic accuracy, clinical management, and the ability to accrue fluid for tumor markers. Methods A multicenter prospective trial randomized 250 patients with PCLs ≥ 13 mm 2:1:1 to 19G Flex, 19G, and 22G needles with crossover for repeated FNA procedures. Diagnostic accuracy was established at 2-year follow-up, with the final diagnosis from surgical histopathology or consensus diagnosis by experts based sequentially on clinical presentation, imaging, and aspirate analysis in blinded review. Results Enrolled patients (36 % symptomatic) had PCLs in the head (44 %), body (28 %), and tail (26 %). Percentage of cyst volume aspirated was 78 % (72 % – 84 %) for 19G Flex, 74 % (64 % – 84 %) for 22G, and 73 % (63 % – 83 %) for 19G (P = 0.84). Successful FNA was significantly higher for 19G Flex (89 % [82 % – 94 %]) and 22G (82 % [70 % – 90 %]) compared with 19G (75 % [63 % – 85 %]) (P = 0.02). Repeated FNA was required more frequently in head/uncinate lesions than in body and tail (P < 0.01). Diagnostic accuracy of the cyst aspirate was 84 % (73 % – 91 %) against histopathology at 2-year follow-up (n = 79), and 77 % (70 % – 83 %) against consensus diagnosis among nonsurgical cases (n = 171). Related serious adverse events occurred in 1.2 % (0.2 % – 3.5 %) of patients. Conclusions Our study results demonstrate a statistically significant difference among the three needles in the overall success rate for aspiration, but not in the percentage of cyst volume aspirated. Flexible needles may be particularly valuable in sampling cystic PCLs in the pancreatic head/uncinate process.
Multicenter study on the diagnostic performance of multiframe volumetric laser endomicroscopy targets for Barrett’s esophagus neoplasia with histopathology correlation

Diseases of the Esophagus | July 1, 2020 | Volume: 33 | Issue: 12 | Pages: No page available

10.1093/dote/doaa062 | PMID 32607539

AbstractVolumetric laser endomicroscopy (VLE) has been shown to improve detection of early neoplasia in Barrett’s esophagus (BE). However, diagnostic performance using histopathology-correlated VLE regions of interest (ROIs) has not been adequately studied. We evaluated the diagnostic accuracy of VLE assessors for identification of early BE neoplasia in histopathology-correlated VLE ROIs. In total, 191 ROIs (120 nondysplastic and 71 neoplastic) from 50 BE patients were evaluated in a random order using a web-based module. All ROIs contained histopathology correlations enabled by VLE laser marking. Assessors were blinded to endoscopic BE images and histology. ROIs were first scored as nondysplastic or neoplastic. Level of confidence was assigned to the predicted diagnosis. Outcome measures were: (i) diagnostic performance of VLE assessors for identification of BE neoplasia in all VLE ROIs, defined as accuracy, sensitivity, and specificity; (ii) diagnostic performance of VLE assessors for only high level of confidence predictions; and (iii) interobserver agreement. Accuracy, sensitivity, and specificity for BE neoplasia identification were 79% (confidence interval [CI], 75–83), 75% (CI, 71–79), and 81% (CI, 76–86), respectively. When neoplasia was identified with a high level of confidence, accuracy, sensitivity, and specificity were 88%, 83%, and 90%, respectively. The overall strength of interobserver agreement was fair (k = 0.29). VLE assessors can identify BE neoplasia with reasonable diagnostic accuracy in histopathology-correlated VLE ROIs, and accuracy is enhanced when BE neoplasia is identified with high level of confidence. Future work should focus on renewed VLE image reviewing criteria and real-time automatic assessment of VLE scans.
Expert assessment on volumetric laser endomicroscopy full scans in Barrett’s esophagus patients with or without high grade dysplasia or early cancer

Endoscopy | June 25, 2020 | Volume: 53 | Issue: 03 | Pages: 218-225

10.1055/a-1194-0397 | PMID 32515006

Abstract Background Volumetric laser endomicroscopy (VLE) allows for near-microscopic imaging of the superficial esophageal wall and may improve detection of early neoplasia in Barrett’s esophagus (BE). Interpretation of a 6-cm long, circumferential VLE “full scan” may however be challenging for endoscopists. We aimed to evaluate the accuracy of VLE experts in correctly diagnosing VLE full scans of early neoplasia and non-dysplastic BE (NDBE). Methods 29 VLE full scan videos (15 neoplastic and 14 NDBE) were randomly evaluated by 12 VLE experts using a web-based module. Experts were blinded to the endoscopic BE images and histology. The 15 neoplastic cases contained a subtle endoscopically visible lesion, which on endoscopic resection showed high grade dysplasia or cancer. NDBE cases had no visible lesions and an absence of dysplasia in all biopsies. VLE videos were first scored as “neoplastic” or “NDBE.” If neoplastic, assessors located the area most suspicious for neoplasia. Primary outcome was the performance of VLE experts in differentiating between non-dysplastic and neoplastic full scan videos, calculated by accuracy, sensitivity, and specificity. Secondary outcomes included correct location of neoplasia, interobserver agreement, and level of confidence. Results VLE experts correctly labelled 73 % (95 % confidence interval [CI] 67 % – 79 %) of neoplastic VLE videos. In 54 % (range 27 % – 66 %) both neoplastic diagnosis and lesion location were correct. NDBE videos were consistent with endoscopic biopsies in 52 % (95 %CI 46 % – 57 %). Interobserver agreement was fair (kappa 0.28). High level of confidence was associated with a higher rate of correct neoplastic diagnosis (81 %) and lesion location (73 %). Conclusions Identification of subtle neoplastic lesions in VLE full scans by experts was disappointing. Future studies should focus on improving methodologies for reviewing full scans, development of refined VLE criteria for neoplasia, and computer-aided diagnosis of VLE scans.
863 Single-Use Duodenoscope for Endoscopic Retrograde Cholangiopancreatography: Performance Ratings From a Case Series of 60 Patients

American Journal of Gastroenterology | October 8, 2019 | Volume: 114 | Issue: 1 | Pages: S501-S501

10.14309/01.ajg.0000592988.58172.47

INTRODUCTION: Exogenous transmission of infection via duodenoscope cross-contamination after failed disinfection is a preventable risk. Inadequate reprocessing of reusable duodenoscopes can occur. Given this possibility, a new single-use duodenoscope was recently developed. It had comparable performance to reusable duodenoscopes when tested by expert endoscopists in a comparative bench model for endoscopic retrograde cholangiopancreatography (ERCP). We subsequently aimed to assess the performance of this disposable duodenoscope in a series of human cases. METHODS: Six academic medical centers enrolled consecutive adults 18 years or older without altered pancreaticobiliary anatomy scheduled for an ERCP. Seven ERCP experts rated the new EXALT single-use Model D duodenoscope (Boston Scientific, Marlborough, MA; ClinicalTrials.gov NCT03701958) in ERCP procedures for Overall Satisfaction on a scale of 1 (unsatisfied) to 10 (very satisfied), “Not preferred/Neutral/Preferred” compared to reusable duodenoscopes on 23 ERCP maneuvers, and Qualitative Comparison of 17 performance characteristics on a scale of 1 (not preferred) to 5 (comparable to reusable duodenoscopes). RESULTS: Sixty consecutive patients had an ERCP using the first-generation single-use duodenoscope in April and May 2019. Thirty-seven (61.7%) were male, mean age was 64.4 years, and 44 (73.3%) had a prior ERCP at baseline. All 60 ERCP procedures were successfully performed, 58 (96.7%) with the single-use duodenoscope alone and 2 (3.3%) with crossover to a reusable duodenoscope. Median overall satisfaction with the single-use duodenoscope was rated 9.0 (range 1-10). The overall satisfaction rating was ≥ 7 in 56 (93.3%) ERCPs. All three ratings were at or above midpoint (Overall satisfaction ≥ 5, Comparative ERCP maneuver “Neutral/Preferred,” Qualitative Comparative rating of performance characteristic 3-5) in 47 (78.3%) cases. Four ERCPs had low (≤4) overall satisfaction ratings attributed to inadequate pushability of instruments due to suboptimal positioning of the duodenoscope in front of the papilla; these ERCPs were a subset in which biliary or pancreatic duct strictures were dilated and/or stented. CONCLUSION: Expert endoscopists reported good overall performance of a new single-use duodenoscope in a broad array of cases. Low ratings occurred rarely and were associated with particular ERCP maneuvers. Detailed design improvements to the single-use duodenoscope are underway.
Volumetric laser endomicroscopy and its application to Barrett's esophagus: results from a 1,000 patient registry

Diseases of the Esophagus | April 30, 2019 | Volume: 32 | Issue: 9 | Pages: No page available

10.1093/dote/doz029 | PMID 31037293

SUMMARY Volumetric laser endomicroscopy (VLE) uses optical coherence tomography (OCT) for real-time, microscopic cross-sectional imaging. A US-based multi-center registry was constructed to prospectively collect data on patients undergoing upper endoscopy during which a VLE scan was performed. The objective of this registry was to determine usage patterns of VLE in clinical practice and to estimate quantitative and qualitative performance metrics as they are applied to Barrett's esophagus (BE) management. All procedures utilized the NvisionVLE Imaging System (NinePoint Medical, Bedford, MA) which was used by investigators to identify the tissue types present, along with focal areas of concern. Following the VLE procedure, investigators were asked to answer six key questions regarding how VLE impacted each case. Statistical analyses including neoplasia diagnostic yield improvement using VLE was performed. One thousand patients were enrolled across 18 US trial sites from August 2014 through April 2016. In patients with previously diagnosed or suspected BE (894/1000), investigators used VLE and identified areas of concern not seen on white light endoscopy (WLE) in 59% of the procedures. VLE imaging also guided tissue acquisition and treatment in 71% and 54% of procedures, respectively. VLE as an adjunct modality improved the neoplasia diagnostic yield by 55% beyond the standard of care practice. In patients with no prior history of therapy, and without visual findings from other technologies, VLE-guided tissue acquisition increased neoplasia detection over random biopsies by 700%. Registry investigators reported that VLE improved the BE management process when used as an adjunct tissue acquisition and treatment guidance tool. The ability of VLE to image large segments of the esophagus with microscopic cross-sectional detail may provide additional benefits including higher yield biopsies and more efficient tissue acquisition. Clinicaltrials.gov NCT02215291