Citations 28

Pancreatic Stiffness Quantified with MR Elastography: Relationship to Postoperative Pancreatic Fistula after Pancreaticoenteric Anastomosis

Radiology | April 17, 2018 | Volume: 288 | Issue: 2 | Pages: 476-484

10.1148/radiol.2018170450 | PMID 29664337

Magnetization‐prepared shells trajectory with automated gradient waveform design

Magnetic Resonance in Medicine | August 22, 2017 | Volume: 79 | Issue: 4 | Pages: 2024-2035

10.1002/mrm.26863 | PMID 28833440

PurposeTo develop a fully automated trajectory and gradient waveform design for the non‐Cartesian shells acquisition, and to develop a magnetization‐prepared (MP) shells acquisition to achieve an efficient three‐dimensional acquisition with improved gray‐to‐white brain matter contrast.MethodsAfter reviewing the shells k‐space trajectory, a novel, fully automated trajectory design is developed that allows for gradient waveforms to be automatically generated for specified acquisition parameters. Designs for two types of shells are introduced, including fully sampled and undersampled/accelerated shells. Using those designs, an MP‐Shells acquisition is developed by adjusting the acquisition order of shells interleaves to synchronize the center of k‐space sampling with the peak of desired gray‐to‐white matter contrast. The feasibility of the proposed design and MP‐Shells is demonstrated using simulation, phantom, and volunteer subject experiments, and the performance of MP‐Shells is compared with a clinical Cartesian magnetization‐prepared rapid gradient echo acquisition.ResultsInitial experiments show that MP‐Shells produces excellent image quality with higher data acquisition efficiency and improved gray‐to‐white matter contrast‐to‐noise ratio (by 36%) compared with the conventional Cartesian magnetization‐prepared rapid gradient echo acquisition.ConclusionWe demonstrated the feasibility of a three‐dimensional MP‐Shells acquisition and an automated trajectory design to achieve an efficient acquisition with improved gray‐to‐white matter contrast. Magn Reson Med 79:2024–2035, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems

Magnetic Resonance in Medicine | June 23, 2017 | Volume: 79 | Issue: 3 | Pages: 1354-1364

10.1002/mrm.26789 | PMID 28643408

PurposeTo investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation.MethodsAfter briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first‐order CFs on these systems are investigated using extended‐phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real‐time compensations using frequency tracking and gradient pre‐emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan‐based correction to compensate for eddy currents is also investigated.ResultsIt is demonstrated that, unlike the second‐order CFs on conventional gradients, the additional zeroth/first‐order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin‐echo acquisitions within a typical brain‐scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real‐time compensation successfully eliminates the artifacts.ConclusionsWe demonstrate that the zeroth/first‐order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real‐time compensation. Magn Reson Med 79:1354–1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 | PMID 28639370

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system

Physics in Medicine & Biology | December 29, 2016 | Volume: 62 | Issue: 2 | Pages: N18-N31

10.1088/1361-6560/aa524f | PMID 28033119

Abstract Due to engineering limitations, the spatial encoding gradient fields in conventional magnetic resonance imaging cannot be perfectly linear and always contain higher-order, nonlinear components. If ignored during image reconstruction, gradient nonlinearity (GNL) manifests as image geometric distortion. Given an estimate of the GNL field, this distortion can be corrected to a degree proportional to the accuracy of the field estimate. The GNL of a gradient system is typically characterized using a spherical harmonic polynomial model with model coefficients obtained from electromagnetic simulation. Conventional whole-body gradient systems are symmetric in design; typically, only odd-order terms up to the 5th-order are required for GNL modeling. Recently, a high-performance, asymmetric gradient system was developed, which exhibits more complex GNL that requires higher-order terms including both odd- and even-orders for accurate modeling. This work characterizes the GNL of this system using an iterative calibration method and a fiducial phantom used in ADNI (Alzheimer’s Disease Neuroimaging Initiative). The phantom was scanned at different locations inside the 26 cm diameter-spherical-volume of this gradient, and the positions of fiducials in the phantom were estimated. An iterative calibration procedure was utilized to identify the model coefficients that minimize the mean-squared-error between the true fiducial positions and the positions estimated from images corrected using these coefficients. To examine the effect of higher-order and even-order terms, this calibration was performed using spherical harmonic polynomial of different orders up to the 10th-order including even- and odd-order terms, or odd-order only. The results showed that the model coefficients of this gradient can be successfully estimated. The residual root-mean-squared-error after correction using up to the 10th-order coefficients was reduced to 0.36 mm, yielding spatial accuracy comparable to conventional whole-body gradients. The even-order terms were necessary for accurate GNL modeling. In addition, the calibrated coefficients improved image geometric accuracy compared with the simulation-based coefficients.
Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems

Magnetic Resonance in Medicine | July 4, 2016 | Volume: 77 | Issue: 6 | Pages: 2250-2262

10.1002/mrm.26315 | PMID 27373901

Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction

Magnetic Resonance in Medicine | July 17, 2015 | Volume: 75 | Issue: 6 | Pages: 2534-2544

10.1002/mrm.25842 | PMID 26183425

PurposeTo describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction.MethodsStarting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction.ResultsPhantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL‐induced coarse‐scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries.ConclusionNoniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534–2544, 2016. © 2015 Wiley Periodicals, Inc.
Integrated image reconstruction and gradient nonlinearity correction

Magnetic Resonance in Medicine | October 8, 2014 | Volume: 74 | Issue: 4 | Pages: 1019-1031

10.1002/mrm.25487 | PMID 25298258

PurposeTo describe a model‐based reconstruction strategy for routine magnetic resonance imaging that accounts for gradient nonlinearity (GNL) during rather than after transformation to the image domain, and demonstrate that this approach reduces the spatial resolution loss that occurs during strictly image‐domain GNL‐correction.MethodsAfter reviewing conventional GNL‐correction methods, we propose a generic signal model for GNL‐affected magnetic resonance imaging acquisitions, discuss how it incorporates into contemporary image reconstruction platforms, and describe efficient nonuniform fast Fourier transform‐based computational routines for these. The impact of GNL‐correction on spatial resolution by the conventional and proposed approaches is investigated on phantom data acquired at varying offsets from gradient isocenter, as well as on fully sampled and (retrospectively) undersampled in vivo acquisitions.ResultsPhantom results demonstrate that resolution loss that occurs during GNL‐correction is significantly less for the proposed strategy than for the standard approach at distances >10 cm from isocenter with a 35 cm field‐of‐view gradient coil. The in vivo results suggest that the proposed strategy better preserves fine anatomical detail than retrospective GNL‐correction while offering comparable geometric correction.ConclusionAccounting for GNL during image reconstruction allows geometric distortion to be corrected with less spatial resolution loss than is typically observed with the conventional image domain correction strategy. Magn Reson Med 74:1019–1031, 2015. © 2014 Wiley Periodicals, Inc.