Background: AI-ECG is a cost-effective tool for left ventricular dysfunction (LVD) screening. However, its cost-effectiveness for other forms of structural heart disease (SHD) is unknown. While AI-ECG is inexpensive, a drawback is low positive predictive value (PPV), which leads to high costs from unnecessary follow-up tests. Therefore, strategies to improve the yield of AI-ECG-based screening are needed. Aim: To evaluate the cost savings of a stepwise approach to SHD screening with AI-ECG followed by POCUS compared to AI-ECG alone. Methods: 286 adult outpatients undergoing AI-ECG were selected at random. Participants received same-day POCUS and had a recent TTE (our gold standard for SHD). We evaluated four SHDs: aortic stenosis (AS), cardiac amyloidosis (CA), HCM, and LVD. The costs of AI-ECG ($75) and TTE ($1,305) were obtained from Healthcare Bluebook. The cost of POCUS ($100) was estimated independently. Cost savings were analyzed for simultaneous screening for all forms of SHD and screening for individual SHDs. Results: AI-ECG identified potential SHD in 125 patients, but only 39 were true positives by TTE (31% PPV). In AI-ECG positive patients, POCUS demonstrated findings of SHD in 52/125. Compared to TTE, this stepwise approach yielded 32 true positives and 20 false positives (62% PPV). The cost per patient diagnosed with SHD was $4,733 with AI-ECG alone but decreased to $3,182 with stepwise screening (33% cost savings). Screening for individual SHDs resulted in cost reduction from $18,724 to $6,315 (66% savings) for AS, $21,023 to $12,230 (42% savings) for CA, $9,883 to $6,175 (38% savings) for HCM, and $4,019 to $3,582 (11% savings) for LVD. Conclusions: Stepwise screening for SHD with AI-ECG followed by POCUS significantly reduces costs compared to AI-ECG alone. We also suggest a model for parallel screening for multiple SHDs, which is likely more cost-effective than screening for individual SHDs.
Abstract 4142252: Impact of Diagnosis to Ablation Time on Recurrence of Atrial Fibrillation and Clinical Outcomes after Catheter Ablation: A Systematic Review and Meta-analysis with Reconstructed Time-to-Event Data.
Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available
Background: Current clinical guidelines emphasize the significance of rhythm control with catheter ablation but lack guidance on the timing after diagnosing atrial fibrillation (AF). Purpose: We aim to investigate the latest evidence on the impact of diagnosis to ablation time (DAT) on AF recurrence, all-cause mortality, stroke, and heart failure (HF) after AF catheter ablation. Methods: We comprehensively searched PubMed, WOS, SCOPUS, EMBASE, and CENTRAL through February 2024. We conducted a pair-wise and prognostic systematic review and meta-analysis with a reconstructed time-to-event data meta-analysis. All analyses were performed using R V. 4.3.1. PROSPERO ID: CRD42024525542. Results: With the inclusion of 22 studies, our cohort comprised a total of 42,101 patients. Regarding pair-wise meta-analysis, shorter DAT was significantly associated with a decreased incidence of AF recurrence across paroxysmal and persistent AF subgroups. Moreover, DAT ≤ one year was significantly associated with a decreased incidence of all-cause mortality (RR: 0.73 with 95% CI [0.59, 0.92], P< 0.01) with a trend toward lowering the risk of stroke (RR: 0.80 with 95% CI [0.62, 1.03], P= 0.08). However, there was no significant difference between DAT ≤ one year and DAT > one year in HF. Regarding adjusted prognostic meta-analysis, longer DAT was significantly associated with an increased risk of AF recurrence (P < 0.01). Our reconstructed Kaplan Meier showed that DAT > one year was significantly associated with a 50% increase in the risk of AF recurrence compared to DAT ≤ one year (HR: 1.50 with 95% CI [1.42, 1.58], P< 0.00001) over 60 months follow-up. Conclusion: Our meta-analysis strongly underscores the critical importance of a short DAT in significantly reducing AF recurrence and all-cause mortality, with a trend toward lowering stroke risk, though no significant impact on HF was observed. Early ablation proves beneficial not only for patients with paroxysmal AF but also for those with persistent AF. These findings suggest that minimizing DAT can markedly improve AF outcomes, warranting further investigation to optimize treatment strategies.
Abstract 4123956: Upgrade to Implantable Cardioverter-Defibrillator in Patients Diagnosed with Cardiac Sarcoidosis after Permanent Pacemaker Implantation for High-Grade Atrioventricular Block
Circulation | November 13, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available
Introduction: Unexplained high-grade AV block (AVB) in patients age <65 years is among the salient features of cardiac sarcoidosis (CS). Guidelines recommend that CS patients with high-grade AVB should receive an implantable cardioverter-defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D) rather than a permanent pacemaker (PPM). However, in clinical practice, CS may be recognized after PPM implantation for high-grade AVB. Aims: To evaluate the characteristics and outcomes of patients diagnosed with CS after PPM implantation for high-grade AVB and assess the decision-making and rationale for upgrade to ICD/CRT-D. Methods: Retrospective review of the Mayo Clinic Sarcoid Registry (n=848) was performed to identify all patients for which a PPM was implanted for high-grade AVB prior to the diagnosis of CS. Baseline clinical and imaging characteristics were collected during index evaluation at our institution. Decision-making for ICD upgrade, lead management strategy, immunosuppression initiation, and outcomes were assessed. Results: Overall, 29 of 848 (3.4%) of CS patients (62% probable/definite CS; 77% male; median (IQR) age 56 (48-61) years; and median (IQR) LVEF 58% (50-62) received a PPM for high-grade AVB prior to a CS diagnosis. Median (IQR) interval between PPM implant and index evaluation was 10 (3-23) months. Eight of 29 patients underwent upgrade to ICD (n=4) or CRT-D (n=4). Among them, the pacing lead was extracted in 4. All patients were upgraded for primary prevention of sudden cardiac death (SCD), with 3 of them also having LVEF<50% requiring upgrade to CRT-D. Twenty-two (79%) patients in the total cohort were treated with immunosuppression. During median (IQR) follow-up 37 months (11-74), 1 patient in the upgrade group had sustained VT appropriately treated with anti-tachycardia pacing. No events were documented among patients in the non-upgrade group. At last follow-up, 6 (75%) patients in the upgrade group and 12 (57%) in the non-upgrade group were pacemaker dependent. Median LVEF change was 0% in patients who underwent upgrade to CRT-D and –0.2% in those who underwent upgrade to ICD or no upgrade. Conclusions: In this cohort of patients diagnosed with CS several months after a PPM had been implanted for high-grade AVB, incident VT/VF was infrequent with contemporary CS management. In the absence of other SCD risk factors, CS patients who received a PPM for high-grade AVB prior to their CS diagnosis may not require ICD upgrade.
Abstract 4148095: The Impact of Body-Mass Index on Ventricular Tachycardia Outcomes Post-Catheter Ablation
Circulation | November 11, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available
Background: In recent years, catheter ablation has emerged as a sustainable, first-line therapy for the management of ventricular tachycardia (VT). Given the rise of the “obesity paradox” theory in atrial ablation outcomes, we sought to study the effect of BMI on patients undergoing structural VT ablation. Purpose: To assess the outcomes of VT ablation, specifically VT recurrence, in patients with elevated vs. normal BMI. Methods: Clinical characteristics and demographic data were collected for VT patients who underwent ablation at Mayo Clinic Rochester from 2012-2022. Patient BMI was classified as non-obese (<30 kg/m2), obese (30-40 kg/m2), and morbidly obese (≥40 kg/m2). The endpoint was a composite of initial monomorphic VT recurrence and repeat ablation after adjusting for age, sex, and comorbidities. Results: A total of 399 patients underwent 508 ablations. 51.4% of ablations had a BMI <30, 39.2% were between 30-40, and 9.4% were ≥40. There was a greater prevalence of hypertension and type 2 diabetes mellitus in morbidly obese patients (p <0.01). Morbidly obese individuals also had a significantly increased rate of general anesthesia during ablation and long VT cycle lengths. The Kaplan-Meier curve demonstrates no statistically significant differences in time to VT recurrence among the three BMI groups (p = 0.324). Neither morbid-obesity (aHR= 1.20; CI = 0.94-1.56, p = 0.14) nor nonmorbid-obesity (aHR = 0.92; CI = 0.76-1.10, p = 0.4), compared to non-obesity was a significant independent predictor of VT recurrence or repeat ablation on multivariate regression after adjusting for age, sex and comorbidities. Conclusion: There was no significant association between BMI groups and VT recurrence or repeat ablation, and no difference in complications. We did not find the obesity paradox to be relevant for VT ablation in our patient population. Further study would be needed with larger samples to corroborate these findings.
Abstract 4136926: Premature Ventricular Complexes and Nonsustained Ventricular Tachycardia in Cardiac Sarcoidosis
Circulation | November 11, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available
Introduction: The prevalence and prognostic significance of PVC and NSVT in cardiac sarcoidosis (CS), especially in patients with normal or mildly decreased LV function, are not well known and were investigated in the current study. Methods: We included 192 patients with definite and probable CS with LVEF>35%, no prior history of VT/VF or sudden cardiac death, who underwent up to 48 hours of Holter monitoring. They were followed retrospectively for the composite endpoint of sustained VT/VF, advanced heart failure therapy, and all-cause mortality. We performed multivariable analysis for the association of PVC burden and NSVT with the composite endpoint. Covariates were considered if they were present in at least 95% of the study sample and were significantly associated with the composite endpoint in univariable analysis. Results: The median PVC burden in the overall population was 0.3% (IQR 0.02-2.5%) and 36 (18.8%) patients had a PVC burden ≥5%. Sixty-two (32.3%) patients had NSVT detected during monitoring. The PVC burden and prevalence of NSVT in patient subgroups are shown in Figures 1 and 2. A total of 33 (17.2%) patients experienced one of the composite endpoints at a median follow-up of 3 years. In the multivariable analysis (Figure 3), PVC burden ≥5% versus <5% (HR 3.96 [1.19, 5.97], p-value <0.01) and presence of NSVT (HR 4.55 [2.09, 9.94], p-value <0.01) were associated with the composite outcome. Conclusion: Our results suggest that a high PVC burden and the presence of NSVT carry isolated prognostic value in CS. In addition, ventricular ectopy does not appear to be an indicator of disease activity based on abnormal uptake on PET scan.
Artificial intelligence-enabled electrocardiogram for left ventricular diastolic dysfunction and long-term risk of new-onset atrial fibrillation
European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available
Abstract Background Heart failure (HF) and atrial fibrillation (AF) are intertwined, sharing common risk factors and influencing each other in a reciprocal manner. While left ventricular diastolic dysfunction (LVDD) stands as a hallmark of HF's hemodynamic profile, its direct correlation with heightened AF risk remains uncertain. Our recent validation of an artificial intelligence-enabled electrocardiogram (AI-ECG) algorithm for LVDD detection has opened new avenues. Yet, whether AI-ECG-detected LVDD correlates with long-term AF risk remains unexplored. Methods We performed a retrospective study among all patients with a comprehensive LVDD assessment from the test population of the AI-ECG LVDD study between September 2001 and June 2022. Patients with prior documented AF according to health records or previous ECG were excluded. Patients were classified by AI-ECG as normal diastolic function (DF), grade 1 (G1), grade 2 (G2), or grade 3 (G3) LVDD. We assessed the risk of AF across AI-ECG LVDD grade, with normal DF as reference, with competing risk models. Results Of 97,023 patients free of AF at baseline, 63,533 (65.4%), 10,776 (11.1%), 18,940 (19.5%), and 3,774 (3.9%) were classified as normal DF, G1-LVDD, G2-LVDD, and G3-LVDD, respectively. Worse AI-ECG LVDD was associated with older age, lower left ventricular ejection fraction (LVEF), and higher rates of HF, diabetes, hypertension, chronic pulmonary disease, renal failure, and cardiovascular disease (p-of-trend<0.001 for all). Over a median follow-up of 4.8 years (interquartile range 1.8-9.2 years), new-onset AF occurred in 6,795 (7.0%) patients. In multivariable survival analysis, adjusted to multiple risk factors including LVEF and clinical HF, G2 and G3 LVDD, representing patients with high filling pressures, were independently associated with a higher AF-risk [G2-LVDD: adjusted hazard ratio (aHR) 1.64 (95% confidence interval (95%CI) 1.52-1.73), G3-LVDD: aHR 2.24 (95%CI 2.02-2.48)]. Conclusion The AI-ECG LVDD algorithm independently predicts long-term AF risk, regardless of LVEF and clinical HF status, highlighting its potential for identifying high-risk populations and guiding proactive monitoring and management.
Prognostic stratification of patients with mitral regurgitation using artificial intelligence-enhanced electrocardiogram for left ventricular diastolic function assessment
European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available
Abstract Background The determination of left ventricular diastolic dysfunction (LVDD) and filling pressure in patients with significant (>moderate) mitral regurgitation (MR) poses a complex challenge. We recently validated an artificial intelligence-enabled electrocardiogram (AI-ECG) algorithm to detect LVDD and estimate LV filling pressures. Methods This retrospective study sought to examine the risk of all-cause mortality across AI-ECG LVDD grades. Patients from the AI-ECG LVDD study test cohort who underwent transthoracic echocardiography confirming significant MR and an ECG within fourteen days of each other at Mayo Clinic between 09/2001 and 06/2022 were included. LVDD status was determined based on the index ECG, and patients were categorized into groups representing normal diastolic function (NDF) or LVDD grades 1 (G1), 2 (G2), or 3 (G3). Results Of 4,019 patients with significant MR (mean age 69.8, 49.0% women), 1,175 (29.2%), 1,881 (46.8%), and 963 (24.0%) were classified by AI-ECG as NDF/G1-LVDD, G2-LVDD, and G3-LVDD, respectively. The median mitral effective regurgitant orifice area was 26 mm² (interquartile range 20-36 mm²). Over a median follow-up of 3.5 years, 1,636 (40.7%) patients died. In multivariable survival analysis adjusted for multiple risk factors, a worse AI-ECG LVDD grade was independently associated with an increased death risk [G2DD: adjusted hazard ratio (aHR) 1.98 (95% confidence interval (95% CI) 1.63-2.40), G3DD: aHR 2.59 (95% CI 2.09-3.20)]. These findings were consistent when accounting for mitral valve intervention and among patients with >moderate MR or after mitral valve intervention. Conclusion In patients with significant MR, the grading of LVDD by AI-ECG is independently associated with all-cause mortality.
Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches
Circulation: Arrhythmia and Electrophysiology | July 25, 2024 | Volume: 17 | Issue: 8 | Pages: No page available
BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.
Association between COVID‐19 vaccination and atrial arrhythmias in individuals with cardiac implantable electronic devices
Journal of Cardiovascular Electrophysiology | July 23, 2024 | Volume: 35 | Issue: 9 | Pages: 1828-1836
AbstractIntroductionThe impact of mRNA‐based coronavirus disease‐2019 (COVID‐19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown.MethodsBIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID‐19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub‐analyses comparing the effects of the influenza vaccine against the COVID‐19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID‐19 vaccine and non‐vaccinated patients was also performed.ResultsFirst and second doses of the COVID‐19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID‐19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID‐19 vaccine. No significant difference in device therapies was seen pre‐ and postvaccination.ConclusionsThough we report a small but significant increase in the number of CIED‐detected AAs following vaccination for COVID‐19 over a 3‐month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high‐risk groups, specifically males over 70 years of age, following vaccination.
Prospective Study of Patient-Reported Outcomes After Endovascular Renal Ablation in Individuals with Chronic Kidney Pain and Opiate Use
Journal of the American Society of Nephrology | May 17, 2024 | Volume: 31 | Issue: 10S | Pages: 217-217