Citations 260

Abstract 10571: Causes of Early Mortality After Catheter Ablation of Ventricular Tachycardia in Patients With Reduced Left Ventricular Ejection Fraction

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10571

Background: Recognition of the causes of early mortality after ventricular tachycardia (VT) ablation in patients with reduced left ventricular ejection fraction is an essential step toward improving post-procedural outcomes. Objective: This study sought to determine the causes of early mortality (≤30-days) after VT ablation in patients with reduced left ventricular ejection fraction and to understand further the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of all patients undergoing VT ablation in patients with reduced left ventricular ejection fraction from January 1, 2013, to November 10, 2021, at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record within the Mayo Clinic system and outside records. Results: A total of 503 patients (mean age 63 ± 13 years, 11.2% female) with EF <50% were included in the study. The 30-day all-cause mortality rate was 5% (n=25), and the mortality rate due to a procedural complication was 0.4%. Among all 30-day deaths, recurrent VT was the most common primary cause of death (44%). This was followed by decompensated heart failure (28%), procedure-related death (8%), cerebrovascular accident (CVA) (4%), and infection (4%). Most patients (91%) who died from VT had the VT recurrence within three days of the ablation. 76% of patients with early mortality had delayed referral for VT ablation, and 72% opted for comfort care before death. Conclusions: The overall early mortality (≤30-days) rate after catheter ablation of VT in patients with reduced left ventricular ejection fraction was 5%, but the death rate directly due to a procedural complication was only 0.4%. The most common cause of death was recurrent VT, followed by heart failure. Further research into ablation strategies is vital to improving the safety, efficacy, and durability of VT ablation.
Abstract 10567: Sepsis-Related Early Mortality After Transvenous Lead Removal

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10567

Background: Recognition of the infectious characteristics among the sepsis-related early mortality after transvenous lead removal (TLR) is an essential step to improving patient outcomes. Objective: This study sought to understand the infectious characteristic and circumstances among the sepsis-related early mortality after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Patient details were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 2,319 patients were included in the study. The overall 30-day sepsis-related mortality rate was 1.25% (n=29). Among the sepsis-related deaths, 24 patients (83%) had systemic cardiac implantable electronic device (CIED) infection, and 4 patients (14%) initially had isolated pocket infection. The average time from admission to TLR was 11 days. MSSA was the most common organism (n=8, 28%), and this was followed by MRSA (n=4, 14%) and Candida (n=3, 10%). Twenty of these patients (69%) had vegetation on the echocardiogram: vegetation on lead only in 9 patients, vegetation on both valve and lead in 8 patients, and vegetation on valve only in 3 patients. Among valvular vegetations, 5 patients had tricuspid valve vegetations, 3 patients had aortic valve vegetations, 2 patients had mitral valve vegetations, and 1 patient had both mitral and aortic valve vegetation. The average size of vegetation was 1.3±0.8 x 1.1±0.6 cm. Conclusions: The 30-day sepsis-related mortality rate was 1.25%. Among the sepsis-related early deaths, MSSA was the most common organism, and more than two-thirds (69%) of the patients had vegetations on cardiac imaging. This highlights the importance of further research to improve the infection outcome in TLR patients.
Abstract 10559: Causes of Early Mortality After Transvenous Lead Removal

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10559

Background: Recognition of the causes of early mortality after transvenous lead removal (TLR) is an essential step for the development of quality improvement programs. Objective: This study sought to determine the causes of early mortality after TLR and to further understand the circumstances surrounding death after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. The causes of death were further characterized based on whether it was related to the TLR procedure. Results: A total of 2,319 patients were included in the study. The overall 30-day all-cause mortality rate was 3%. Among all 30-day deaths, infection was the most common primary cause of death (42%). This was followed by decompensated heart failure (17%), procedure-related death (10%), sudden cardiac arrest (7%), and respiratory failure (6%). The 30-day mortality rate directly due to complications associated with the TLR procedure was 0.3% due to vascular tear and cardiac perforation. A third of deaths (33%) occurred after discharge from index hospitalization, among which 43% were readmitted before their death, 35% died at home or a nursing facility, and 22% were discharged on comfort care and died in hospice. The main reasons for readmission prior to death were sepsis and decompensated heart failure. Conclusions: The majority (90%) of 30-day mortality after TLR was not due to complications associated with TLR procedures. The primary causes were infection and decompensated heart failure. This highlights the importance of further research to reduce postoperative mortality from these factors, including deaths after hospital discharge.
Voltage-Guided Ablation for Atrial Fibrillation -- Current Insights and Future Directions

No container title available | May 23, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.168483251.13504722/v1

The prevalence of atrial fibrillation (AF) is forecasted to increase manifold, emphasizing the need for efficacious treatments. Pulmonary vein isolation (PVI) to eliminate ectopic triggers is now established as a fundamental component of the invasive treatment of AF, however its efficacy in persistent AF remains suboptimal. The atrial myocardium undergoes adverse fibrotic remodeling as AF progresses, favoring arrhythmia initiation and maintenance. Reductions in left atrial bipolar voltage have been suggested to identify regions of such pathological remodeling, and represent novel targets for ablation to target the arrhythmogenic substrate. Early observational studies targeting these low voltage areas (LVA) have been encouraging, however results from more recent randomized trials are more mixed. Importantly, there is significant heterogeneity in the techniques for identifying LVAs and the strategies for ablation. In reality, the atrial arrhythmogenic substrate is multi-faceted rather than being limited to fibrosis and there remains uncertainty as to how accurately LVAs represent regions of fibrosis. Additionally, bipolar voltage is influenced by numerous physiological and biophysical factors. The present review summarizes the current evidence for LVA ablation in AF. We then analyze the components of the atrial arrhythmic substrate, its relationship to LVAs and the limitations in LVA assessment. Finally we discuss novel techniques for delineating the atrial substrate.
Association of atrial fibrillation and outcomes in patients undergoing bone marrow transplantation

Europace | May 19, 2023 | Volume: 25 | Issue: 5 | Pages: No page available

10.1093/europace/euad129 | PMID 37208304

Abstract Aims Haematopoietic stem cell transplantation (HSCT) is a potentially curative therapy for several malignant and non-malignant haematologic conditions. Patients undergoing HSCT are at an increased risk of developing atrial fibrillation (AF). We hypothesized that a diagnosis of AF would be associated with poor outcomes in patients undergoing HSCT. Methods and results The National Inpatient Sample (2016–19) was queried with ICD-10 codes to identify patients aged &gt;50 years undergoing HSCT. Clinical outcomes were compared between patients with and without AF. A multivariable regression model adjusting for demographics and comorbidities was used to calculate the adjusted odds ratio (aOR) and regression coefficients with corresponding 95% confidence intervals and P-values. A total of 50 570 weighted hospitalizations for HSCT were identified, out of which 5820 (11.5%) had AF. Atrial fibrillation was found to be independently associated with higher inpatient mortality (aOR 2.75; 1.9–3.98; P &lt; 0.001), cardiac arrest (aOR 2.86; 1.55–5.26; P = 0.001), acute kidney injury (aOR 1.89; 1.6–2.23; P &lt; 0.001), acute heart failure exacerbation (aOR 5.01; 3.54–7.1; P &lt; 0.001), cardiogenic shock (aOR 7.73; 3.17–18.8; P &lt; 0.001), and acute respiratory failure (aOR 3.24; 2.56–4.1; P &lt; 0.001) as well as higher mean length of stay (LOS) (+2.67; 1.79–3.55; P &lt; 0.001) and cost of care (+67 529; 36 630–98 427; P &lt; 0.001). Conclusion Among patients undergoing HSCT, AF was independently associated with poor in-hospital outcomes, higher LOS, and cost of care.
Anatomical location of leadless pacemaker and the risk of pacing‐induced cardiomyopathy

Journal of Cardiovascular Electrophysiology | May 10, 2023 | Volume: 34 | Issue: 6 | Pages: 1418-1426

10.1111/jce.15925 | PMID 37161942

Abstract Background It is unclear if the location of implantation of the leadless pacemaker (LP) makes a difference in the incidence of pacing‐induced cardiomyopathy (PICM). Aim The aim of this study was to compare the incidence of PICM based on the location of implantation of LP. Methods A total of 358 consecutive patients [women: 171 (48%), mean age: 73 ± 15 years] with left ventricular ejection fraction (EF) > 50%, who received an LP (Micra) between January 2017 and June 2022, formed the study cohort. Micra‐AV and Micra‐VR were implanted in 122 (34%) and 236 (66%) patients, respectively. Fluoroscopically, the location of implantation of LP in the interventricular septum (IS) was divided into two equal halves (apex/apical septum [AS] and mid/high septum [HS]). During follow‐up, PICM was defined as an EF drop of ≥10%. Results LP was implanted in 109 (34%) and 249 (66%) patients at AS and HS locations, respectively. During a mean 18 ± 8 months follow‐up, 28 patients (7.8%) developed PICM. Among the 249 patients with HS placement of LP, 10 (4%) developed PICM, whereas among the 109 patients with AS placement of LP, 18 (16.5%) developed PICM ( p = .002). AS location was associated with a higher risk of PICM compared to HS locations (adjusted hazard ratio: 4.42, p < .001). Conclusion AS location of LP was associated with a higher risk of PICM compared to HS placement. Larger randomized studies are needed to confirm our findings.
A Tale of Two Parallel Rhythms

Circulation | May 8, 2023 | Volume: 147 | Issue: 19 | Pages: 1463-1466

10.1161/circulationaha.123.064492 | PMID 37155590

Same‐day discharge for left atrial appendage occlusion procedure: A systematic review and meta‐analysis

Journal of Cardiovascular Electrophysiology | May 2, 2023 | Volume: 34 | Issue: 5 | Pages: 1196-1205

10.1111/jce.15914 | PMID 37130436

AbstractIntroductionMost patients undergoing a left atrial appendage occlusion (LAAO) procedure are admitted for overnight observation. A same‐day discharge strategy offers the opportunity to improve resource utilization without compromising patient safety. We compared the patient safety outcomes and post‐discharge complications between same‐day discharge versus hospital admission (HA) (>1 day) in patients undergoing LAAO procedure.MethodsA systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri‐procedural complications, re‐admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all‐cause mortality, and peri‐device leak >5 mm. Mantel–Haenszel risk ratios (RRs) with 95% CIs were calculated.ResultsA total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same‐day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29–1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49–2.73]), peri‐device leak >5 mm (RR: 1.27; 95% CI: [0.42–3.85], and all‐cause mortality (RR: 0.60; 95% CI: [0.36–1.02]). The same‐day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54–0.94]).ConclusionsThis meta‐analysis of seven observational studies showed no significant difference in patient safety outcomes and post‐discharge complications between same‐day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation

Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available

10.1161/circep.122.011365 | PMID 37082954

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
New atrial arrhythmia occurrence in single chamber implantable cardioverter defibrillator patients: A real‐world investigation

Journal of Cardiovascular Electrophysiology | December 29, 2022 | Volume: 34 | Issue: 2 | Pages: 438-444

10.1111/jce.15790 | PMID 36579406

AbstractIntroductionA current limitation of single chamber implantable cardioverter defibrillators (ICDs) is the lack of an atrial lead to reliably detect atrial fibrillation (AF) episodes. A novel ventricular based atrial fibrillation (VBAF) detection algorithm was created for single chamber ICDs to assess R‐R variability for detection of AF.MethodsPatients implanted with Visia AF™ ICDs were prospectively enrolled in the Medtronic Product Surveillance Registry from December 15, 2015 to January 23, 2019 and followed with at least 30 days of monitoring with the algorithm. Time to device‐detected daily burden of AF ≥ 6 min, ≥6 h, and ≥23 h were reported. Clinical actions after device‐detected AF were recorded.ResultsA total of 291 patients were enrolled with a mean follow‐up of 22.5 ± 7.9 months. Of these, 212 (73%) had no prior history of AF at device implant. However, 38% of these individuals had AF detected with the VBAF algorithm with daily burden of ≥6 min within two years of implant. In these 80 patients with newly detected AF by their ICD, 23 (29%) had a confirmed clinical diagnosis of AF by their provider. Of patients with a clinical diagnosis of AF, nine (39%) were newly placed on anticoagulation, including five of five (100%) patients having a burden >23 h.ConclusionsContinuous AF monitoring with the new VBAF algorithm permits early identification and actionable treatment for patients with undiagnosed AF that may improve patient outcomes.