Citations 93

Age and Sex Normalization of Intestinal Permeability Measures for the Improved Assessment of Enteropathy in Infancy and Early Childhood

Journal of Pediatric Gastroenterology and Nutrition | May 3, 2017 | Volume: 65 | Issue: 1 | Pages: 31-39

10.1097/mpg.0000000000001610 | PMID 28644347

ABSTRACT Objectives: The aim of the study was to describe changes in intestinal permeability in early childhood in diverse epidemiologic settings. Methods: In a birth cohort study, the lactulose:mannitol (L:M) test was administered to 1980 children at 4 time points in the first 24 months of life in 8 countries. Data from the Brazil site with an incidence of diarrhea similar to that seen in the United States and no growth faltering was used as an internal study reference to derive age‐ and sex‐specific z scores for mannitol and lactulose recoveries and the L:M ratio. Results: A total of 6602 tests demonstrated mannitol recovery, lactulose recovery, and the L:M ratio were associated with country, sex, and age. There was heterogeneity in the recovery of both probes between sites with mean mannitol recovery ranging for 1.34% to 5.88%, lactulose recovery of 0.19% to 0.58%, and L:M ratios 0.10 to 0.17 in boys of 3 months of age across different sites. We observed strong sex‐specific differences in both mannitol and lactulose recovery, with boys having higher recovery of both probes. Alterations in intestinal barrier function increased in most sites from 3 to 9 months of age and plateaued or diminished from 9 to 15 months of age. Conclusions: Alterations in recovery of the probes differ markedly in different epidemiologic contexts in children living in the developing world. The rate of change in the L:M‐ z ratio was most rapid and consistently disparate from the reference standard in the period between 6 and 9 months of age, suggesting that this is a critical period of physiologic impact of enteropathy in these populations.
Negligible Thyroid Hormone Content Present in Nonprescription U.S. Weight Loss Products

Thyroid® | November 29, 2016 | Volume: 27 | Issue: 2 | Pages: 300-301

10.1089/thy.2016.0534 | PMID 27897088

Vitamin D-Mediated Hypercalcemia: Mechanisms, Diagnosis, and Treatment

Endocrine Reviews | September 2, 2016 | Volume: 37 | Issue: 5 | Pages: 521-547

10.1210/er.2016-1070 | PMID 27588937

Abstract Hypercalcemia occurs in up to 4% of the population in association with malignancy, primary hyperparathyroidism, ingestion of excessive calcium and/or vitamin D, ectopic production of 1,25-dihydroxyvitamin D [1,25(OH)2D], and impaired degradation of 1,25(OH)2D. The ingestion of excessive amounts of vitamin D3 (or vitamin D2) results in hypercalcemia and hypercalciuria due to the formation of supraphysiological amounts of 25-hydroxyvitamin D [25(OH)D] that bind to the vitamin D receptor, albeit with lower affinity than the active form of the vitamin, 1,25(OH)2D, and the formation of 5,6-trans 25(OH)D, which binds to the vitamin D receptor more tightly than 25(OH)D. In patients with granulomatous disease such as sarcoidosis or tuberculosis and tumors such as lymphomas, hypercalcemia occurs as a result of the activity of ectopic 25(OH)D-1-hydroxylase (CYP27B1) expressed in macrophages or tumor cells and the formation of excessive amounts of 1,25(OH)2D. Recent work has identified a novel cause of non-PTH-mediated hypercalcemia that occurs when the degradation of 1,25(OH)2D is impaired as a result of mutations of the 1,25(OH)2D-24-hydroxylase cytochrome P450 (CYP24A1). Patients with biallelic and, in some instances, monoallelic mutations of the CYP24A1 gene have elevated serum calcium concentrations associated with elevated serum 1,25(OH)2D, suppressed PTH concentrations, hypercalciuria, nephrocalcinosis, nephrolithiasis, and on occasion, reduced bone density. Of interest, first-time calcium renal stone formers have elevated 1,25(OH)2D and evidence of impaired 24-hydroxylase-mediated 1,25(OH)2D degradation. We will describe the biochemical processes associated with the synthesis and degradation of various vitamin D metabolites, the clinical features of the vitamin D-mediated hypercalcemia, their biochemical diagnosis, and treatment.
Improving the detection of environmental enteric dysfunction: a lactulose, rhamnose assay of intestinal permeability in children aged under 5 years exposed to poor sanitation and hygiene

BMJ Global Health | July 4, 2016 | Volume: 1 | Issue: 1 | Pages: e000066

10.1136/bmjgh-2016-000066 | PMID 28588929

Background Environmental enteric dysfunction (EED) is an asymptomatic intestinal disorder affecting populations living in conditions of poor sanitation and hygiene. The study tested intestinal barrier function in infants with EED. Methods We prospectively studied an advanced high-performance liquid chromatography mass spectrometry assay of urine collected after oral intake of the monosaccharide, L-rhamnose and the disaccharide, lactulose, in 112 children from three continents. Findings Compared to the US cohort (n=27), the cohorts of children from Peru (n=19) and Zambia (n=85) were older with evidence of growth impairment. The median (range) of age (months) was 8.0 (2.0 to 13.0), 27.0 (15.0 to 29.0) and 21.0 (12.0 to 36.0), respectively. The median (range) of height for age Z score was −0.1 (−1.8 to 2.4), −1.8 (−3.3 to −0.2) and −2.3 (−8.5 to 1.2), respectively. Among children with valid sugar data (n=22 USA, n=19 Peru, n=73 Zambia), there were no significant differences in the median rhamnose urine concentrations between the three groups. The median (range) lactulose concentration (µg/mL) was 6.78 (0.29 to 31.90), 47.60 (4.23 to 379.00) and 75.40 (0.67 to 873.00) in the US, Peruvian and Zambian cohorts, respectively (p<0.001). The lactulose/rhamnose ratio (LRR) was higher in cohorts from Peru (0.75, 0.15, 5.02) and Zambia (2.26, 0.08, 14.48) compared to the US (0.14, 0.06, 1.00) cohort (p<0.001). In a multivariate effect modification model, higher weight-for-age z scores were associated with lower post-dose lactulose when rhamnose excretion was constant (p=0.003). Conclusions This non-invasive two saccharide permeability protocol measures changes in intestinal permeability in children with EED and permits the identification of individuals for interventional trials.
Commentary

Clinical Chemistry | June 29, 2016 | Volume: 62 | Issue: 7 | Pages: 928-928

10.1373/clinchem.2015.253484 | PMID 27354567

Recommendations for the Generation, Quantification, Storage, and Handling of Peptides Used for Mass Spectrometry–Based Assays

Clinical Chemistry | December 30, 2015 | Volume: 62 | Issue: 1 | Pages: 48-69

10.1373/clinchem.2015.250563 | PMID 26719571

AbstractBACKGROUNDFor many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope–labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays.CONTENTThe Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials—in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry—is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.
LC-MS/MS for Identifying Patients with CYP24A1 Mutations

Clinical Chemistry | December 30, 2015 | Volume: 62 | Issue: 1 | Pages: 236-242

10.1373/clinchem.2015.244459 | PMID 26585929

Abstract BACKGROUND Patients have been described with loss-of-function CYP24A1 (cytochrome P450, family 24, subfamily A, polypeptide 1) mutations that cause a high ratio of 25-hydroxyvitamin D to 24,25-dihydroxyvitamin D [25(OH)D/24,25(OH)2D], increased serum 1,25-dihydroxyvitamin D, and resulting hypercalcemia, hypercalciuria and nephrolithiasis. A 25(OH)D/24,25(OH)2D ratio that can identify patients who are candidates for confirmatory CYP24A1 genetic testing would be valuable. We validated an LC-MS/MS assay for 24,25(OH)2D (D3 and D2) and determined a 25(OH)D/24,25(OH)2D cutoff to identify candidates for confirmatory genetic testing. METHODS After addition of isotope-labeled internal standard, serum samples were extracted by solid-phase extraction, derivatized with 4-phenyl-1,2,4,-triazoline-3,5-dione, and quantified by LC-MS/MS. We measured 25(OH)D/24,25(OH)2D in 91 healthy patients and 34 patients with clinically suspected CYP24A1-mediated hypercalcemia. RESULTS The limits of detection and quantification were 0.03 (0.2) and 0.1 (0.24) nmol/L, respectively, for 24,25(OH)2D3, and 0.1 (0.23) and 0.5 (1.16) nmol/L for 24,25(OH)2D2. Intra- and interassay imprecision was 4%–15% across the analytical measurement range of 0.1–25 ng/mL (0.2–60 nmol/L). No interference was observed with 25(OH)D and 1,25(OH)2D. 25(OH)D/24,25(OH)2D of 7–35 was observed in healthy patients, whereas in 2 patients with CYP24A1 mutations, 25(OH)D/24,25(OH)2D was significantly increased (99–467; P &lt; 0.001). A 25(OH)D/24,25(OH)2D ratio ≥99 identified patients who were candidates for CYP24A1 genetic testing. CONCLUSIONS Increased 25(OH)D/24,25(OH)2D supports the diagnosis of reduced CYP24A1 activity due to mutations in CYP24A1. Measurement of 25(OH)D/24,25(OH)2D should be considered a part of the clinical workup in patients with hypercalcemia of otherwise unknown etiology.
Serum 25-Hydroxyvitamin D Levels: Variability, Knowledge Gaps, and the Concept of a Desirable Range

Journal of Bone and Mineral Research | May 8, 2015 | Volume: 30 | Issue: 7 | Pages: 1119-1133

10.1002/jbmr.2536 | PMID 25952470

ABSTRACT Hypovitaminosis D is prevalent worldwide but proportions vary widely between regions, depending on genetic and lifestyle factors, the threshold to define deficiency, and accuracy of 25-hydroxyvitamin D (25OHD) assays used. Latitude, pollution, concealing clothing, sun exposure, gender, dietary habits, and lack of government regulation account for up to 50% in variations in serum 25OHD levels, whereas genetic polymorphisms in the vitamin D pathway account for less than 5%. Organizations/societies have developed guidelines for recommended desirable 25OHD levels and vitamin D doses to reach them, but their applicability across age groups and populations are still debated. This article and the accompanying online Supporting Information highlight sources of variations in circulating 25OHD levels, uncertainties and knowledge gaps, and analytical problems facing 25OHD assays, while keeping efficacy and safety data as the dominant factors when defining a desirable range for 25OHD levels. We propose a desirable range of 20 to 40 ng/mL (50 to 100 nmol/L), provided precise and accurate assays are used. Although slightly lower levels, 15 to 20 ng/mL, may be sufficient for some infants and adults, higher levels, 40 to 60 ng/mL, may still be safe. This desirable range allows physicians to tailor treatment while taking season, lifestyle, vitamin D intake, and other sources of variation into account. We reserve 25OHD measurements for at-risk patients, defined by disease or lifestyle, and the use of 25OHD assays calibrated against the recommended international standards. Most target groups reach desirable target levels by a daily intake of 400 to 600 IU for children and 800 IU for adults. A total daily allowance of vitamin D of up to 1000 IU in the pediatric age groups, and up to 2000 IU in adults, tailored to an individual patient risk profile, is probably safe over long durations. Additional data are needed to validate the proposed range and vitamin D doses, especially in children, pregnant women, and non-white populations. © 2015 American Society for Bone and Mineral Research.
Serum Concentrations of Prostate-Specific Antigen Measured Using Immune Extraction, Trypsin Digestion, and Tandem Mass Spectrometry Quantification of LSEPAELTDAVK Peptide

Archives of Pathology and Laboratory Medicine | September 30, 2014 | Volume: 138 | Issue: 10 | Pages: 1381-1386

10.5858/arpa.2013-0462-oa | PMID 25268201

Context.— Prostate-specific antigen (PSA) is a 34-kDa glycoprotein with chymotrypsin-like enzyme activity that circulates both in free forms and complexed to various enzyme inhibitors including antichymotrypsin and α 2 -macroglobulin. Prostate-specific antigen bound to α 2 -macroglobulin is not detected by commercial PSA immunoassays. Objective.— To develop a mass spectrometry assay that detects the same forms of PSA as the immunoassays, which could serve as a reference for harmonizing PSA immunoassays. Design.— Prostate-specific antigen was immune extracted from serum, trypsin was digested, and the LSEPAELTDAVK peptide was quantitated on an API 5000 spectrometer. Calibrators were made by adding 10% free and 90% antichymotrypsin-bound PSA to female sera. The assay was standardized to the World Health Organization 96/670 reference standard. Validation of clinical utility and comparisons with 2 immunoassays (Roche cobas and Beckman Access) were performed using frozen sera aliquots from 100 men undergoing prostate biopsy (50 negative, 50 with cancer) and 5 serial samples collected over time from 5 men with advanced prostate cancer. Results.— The antibody extraction efficiency was greater than 99%. The assay has an analytic range from 1.2 to 76 ng/mL, with precision ranging from 8.6% at 1.5 ng/mL to 5.4% at 27 ng/mL. The mass spectrometry assay correlated well with 2 immunoassays. All 3 assays showed statistically equivalent separation of prostate cancer from benign disease using receiver operating characteristic curve analysis. Conclusions.— This mass spectrometry assay can reliably measure PSA concentrations in human serum and could serve as a reference standard for harmonizing PSA immunoassays.
Lactulose

Journal of Pediatric Gastroenterology and Nutrition | June 17, 2014 | Volume: 59 | Issue: 4 | Pages: 544-550

10.1097/mpg.0000000000000459 | PMID 24941958

ABSTRACTObjectives:The lactulose:mannitol (L:M) diagnostic test is frequently used in field studies of environmental enteropathy (EE); however, heterogeneity in test administration and disaccharide measurement has limited the comparison of results between studies and populations. We aim to assess the agreement between L:M measurement between high‐performance liquid chromatography with pulsed amperometric detection (HPLC‐PAD) and liquid chromatography‐tandem mass spectrometry (LC‐MSMS) platforms.Methods:The L:M test was administered in a cohort of Peruvian infants considered at risk for EE. A total of 100 samples were tested for lactulose and mannitol at 3 independent laboratories: 1 running an HPLC‐PAD platform and 2 running LC‐MSMS platforms. Agreement between the platforms was estimated.Results:The Spearman correlation between the 2 LC‐MSMS platforms was high (ρ ≥ 0.89) for mannitol, lactulose, and the L:M ratio. The correlation between the HPLC‐PAD platform and LC‐MSMS platform was ρ = 0.95 for mannitol, ρ = 0.70 for lactulose, and ρ = 0.43 for the L:M ratio. In addition, the HPLC‐PAD platform overestimated the lowest disaccharide concentrations to the greatest degree.Conclusions:Given the large analyte concentration range, the improved accuracy of LC‐MSMS has important consequences for the assessment of lactulose and mannitol following oral administration in populations at risk for EE. We recommend that researchers wishing to implement a dual‐sugar test as part of a study of EE use an LC‐MSMS platform to optimize the accuracy of results and increase comparability between studies.