Citations 51

Clinically Localized Prostate Cancer: AUA/ASTRO Guideline, Part I: Introduction, Risk Assessment, Staging, and Risk-Based Management

Journal of Urology | May 10, 2022 | Volume: 208 | Issue: 1 | Pages: 10-18

10.1097/ju.0000000000002757 | PMID 35536144

GPU‐accelerated Monte Carlo‐based online adaptive proton therapy: A feasibility study

Medical Physics | April 20, 2022 | Volume: 49 | Issue: 6 | Pages: 3550-3563

10.1002/mp.15678 | PMID 35443080

AbstractPurposeTo develop an online graphic processing unit (GPU)‐accelerated Monte Carlo‐based adaptive radiation therapy (ART) workflow for pencil beam scanning (PBS) proton therapy to address interfraction anatomical changes in patients treated with PBS.Methods and MaterialsA four‐step workflow was developed using our in‐house developed GPU‐accelerated Monte Carlo‐based treatment planning system to implement online Monte Carlo‐based ART for PBS. The first step conducts diffeomorphic demon‐based deformable image registration (DIR) to propagate contours on the initial planning CT (pCT) to the verification CT (vCT) to form a new structure set. The second step performs forward dose calculation of the initial plan on the vCT with the propagated contours after manual approval (possible modifications involved). The third step triggers a reoptimization of the plan depending on whether the verification dose meets the clinical requirements or not. A robust evaluation will be done for both the verification plan in the second step and the reopotimized plan in the third step. The fourth step involves a two‐stage (before and after delivery) patient‐specific quality assurance (PSQA) of the reoptimized plan. The before‐delivery PSQA is to compare the plan dose to the dose calculated using an independent fast open‐source Monte Carlo code, MCsquare. The after‐delivery PSQA is to compare the plan dose to the dose recalculated using the log file (spot MU, spot position, and spot energy) collected during the delivery. Jaccard index (JI), dice similarity coefficients (DSCs), and Hausdorff distance (HD) were used to assess the quality of the propagated contours in the first step. A commercial plan evaluation software, ClearCheck™, was integrated into the workflow to carry out efficient plan evaluation. 3D Gamma analysis was used during the fourth step to ensure the accuracy of the plan dose from reoptimization. Three patients with three different disease sites were chosen to evaluate the feasibility of the online ART workflow for PBS.ResultsFor all three patients, the propagated contours were found to have good volume conformance [JI (lowest‐highest: 0.833–0.983) and DSC (0.909–0.992)] but suboptimal boundary coincidence [HD (2.37–20.76 mm)] for organs‐at‐risk. The verification dose evaluated by ClearCheck™ showed significant degradation of the target coverage due to the interfractional anatomical changes. Reoptimization on the vCT resulted in great improvement of the plan quality to a clinically acceptable level. 3D Gamma analyses of PSQA confirmed the accuracy of the plan dose before delivery (mean Gamma index = 98.74% with a threshold of 2%/2 mm/10%), and after delivery based on the log files (mean Gamma index = 99.05% with a threshold of 2%/2 mm/10%). The average time cost for the complete execution of the workflow was around 858 s, excluding the time for manual intervention.ConclusionThe proposed online ART workflow for PBS was demonstrated to be efficient and effective by generating a reoptimized plan that significantly improved the plan quality.
Technical note: Evaluation and second check of a commercial Monte Carlo dose engine for small‐field apertures in pencil beam scanning proton therapy

Medical Physics | March 19, 2022 | Volume: 49 | Issue: 5 | Pages: 3497-3506

10.1002/mp.15604 | PMID 35305269

Abstract Purpose To evaluate the accuracy of the RayStation Monte Carlo dose engine (RayStation MC) in modeling small‐field block apertures in proton pencil beam scanning. Furthermore, we evaluate the suitability of MCsquare as a second check for RayStation MC. Methods We have enhanced MCsquare to model block apertures. To test the accuracy of both RayStation MC and the newly enhanced MCsquare, we compare the dose predictions of each to in‐water dose measurements obtained using diode detectors and radiochromic film. Nine brass apertures with openings of 1, 2, 3, 4, and 5 cm and either 2 cm or 4 cm thickness were used in the irradiation of a water phantom. Two measurement setups were used, one with a range shifter and 119.7 MeV proton beam energy and the other with no range shifter and 147 MeV proton beam energy. To further test the validity of RayStation MC and MCsquare in modeling block apertures and to evaluate MCsquare as a second check tool, 10 small‐field (average target volume 8.3 cm 3 ) patient treatment plans were calculated by each dose engine followed by a statistical comparison. Results Comparing to the absolute dose measurements in water, RayStation MC differed by 1.2% ± 1.0% while MCsquare differed by −1.8% ± 3.7% in the plateau region of a pristine Bragg peak. Compared to the in‐water film measurements, RayStation MC and MCsquare both performed well with an average 2D‐3D gamma passing rate of 99.4% and 99.7% (3%/3 mm), respectively. A t ‐test comparing the agreement with the film measurements between RayStation MC and MCsquare suggested that the relative spatial dose distributions calculated by MCsquare and RayStation MC were statistically indistinguishable. Directly comparing the dose calculations between MCsquare and RayStation MC over 10 patients resulted in an average 3D‐3D gamma passing rates of 98.5% (3%/3 mm) and 94.1% (2%/2 mm), respectively. Conclusion The validity of RayStation MC algorithm for use with patient‐specific apertures has been expanded to include small apertures. MCsquare has been enhanced to model apertures and was found to be an adequate second check of RayStation MC in this scenario.
Abstract PD7-03: Ultra-accelerated photon, proton, and brachytherapy partial breast irradiation: Primary results of the Mayo 3-fraction trial

Cancer Research | March 8, 2022 | Volume: 82 | Issue: 4_Supplement | Pages: PD7-03-PD7-03

10.1158/1538-7445.sabcs21-pd7-03

Abstract Background: Partial breast irradiation (PBI) is an established option for selected patients with early stage breast cancer. The optimal technique, target volume and dose/fractionation for PBI has yet to be defined. The most studied regimen in North America (38.5 Gy in 10 fractions twice daily) has been associated with cosmetic deterioration. We hypothesized that condensing treatment and reducing the total administered dose could improve the therapeutic ratio in luminal breast cancer and DCIS based on emerging evidence that breast cancer is more sensitive than surrounding normal tissues to high dose fractions. Herein, we report cosmetic, tolerability, disease control, and patient reported outcomes of a novel ultra-accelerated PBI regimen. Methods: We conducted a single arm, three cohort trial of photon, proton, and brachytherapy PBI. Technique was selected at physician and patient discretion. Eligible women were age ≥ 50 years with estrogen receptor positive (ER+), sentinel lymph node negative invasive or in-situ breast cancer measuring ≤ 2.5 cm. The regimen was designed to have comparable biologically equivalent effect as 40 Gy in 15 fractions, assuming an α/β ratio of 3.5. Intracavitary brachytherapy target volume was lumpectomy cavity plus 1 cm and prescribed 21 Gy in 3 fractions. Photon and proton target volumes were post-operative tumor bed plus 1 cm and a 3 mm setup uncertainty margin, prescribed 21.9 Gy (RBE) in 3 fractions, and delivered with image guidance. The primary outcome was the percentage difference in patients with adverse cosmesis (defined as fair or poor cosmesis) at 3 years compared to baseline pre-PBI, as assessed by trained nurses using the 4-point Harvard breast cosmesis scale. Patients also completed quality of life surveys and self-reported cosmesis using the 4-point scale. Locoregional and distant recurrence-free survival was determined using the Kaplan-Meier method. Adverse events were assessed using CTCAE, v 4.0. Results: Between 2015 and 2017, 163 patients were treated: photons in 58, protons in 48, and brachytherapy in 57. Median patient age was 66 years. 129 (79%) patients had invasive breast cancer (all ER+) and 34 (21%) had DCIS (83% ER+). Median tumor size was 1.1 cm. Grade was 2-3 in 102 (63%). The median mean heart/ipsilateral lung doses were photons 0.1/1.6 Gy, protons <0.001/0.1 Gy, and brachytherapy 0.5/0.9 Gy. Median follow-up was 4.1 years (IQR 3.9-5.0). The proportion of patients with adverse cosmesis (by RN assessment) was 14.3% at baseline and 3.8% at 3 years, with four patients (1 photon, 1 proton, 2 brachytherapy) experiencing cosmetic deterioration at 3 years from baseline. The proportion with adverse cosmesis by self-report at 3 years was 2.4%, with three patients (1 photon, 1 proton, 1 brachytherapy) reporting cosmetic deterioration. Four patients developed locoregional recurrence (1 photons, 2 protons, 1 brachytherapy); three were local only and one was local and distant. 4-year locoregional recurrence and distant metastasis-free survival were 97.9% and 97.4%, respectively. There were 2 treatment related ≥ grade 2 late events (grade 2 fibrosis and grade 2 seroma, both brachytherapy associated), and no evidence of deterioration in patient-reported pain, fatigue, breast related or overall quality of life, as assessed by the patient reported outcomes version of the CTCAE, 10-point linear analog scales, and the breast cancer treatment outcomes scale. Conclusions: Ultra-accelerated 3-fraction PBI exquisitely spared normal tissues and was associated with favorable cosmetic outcomes, disease control, and excellent long-term tolerability. This ‘precision-radiotherapy’ approach may optimize the therapeutic ratio over more aggressive radiotherapy options as well as radiotherapy omission, particularly in patients with long life expectancies. Citation Format: Robert Mutter, Tina Hieken, Todd DeWees, Arslan Afzal, Stephanie Kenison, Laura Vallow, Christopher Deufel, Nicholas Remmes, Kathryn Ruddy, Judy Boughey, Keith Furutani, Amy Degnim, James Jakub, Tamara Vern-Gross, Dean Shumway, William Wong, Samir Patel, Lisa McGee, Minetta Liu, Carlos Vargas, Daniel Visscher, Bradley Stish, Deanna Pafundi, Mark Waddle, Michael Golafshar, Michele Halyard, Kimberly Corbin, Sean Park. Ultra-accelerated photon, proton, and brachytherapy partial breast irradiation: Primary results of the Mayo 3-fraction trial [abstract]. In: Proceedings of the 2021 San Antonio Breast Cancer Symposium; 2021 Dec 7-10; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2022;82(4 Suppl):Abstract nr PD7-03.
A phase II trial of hypofractionated radiation therapy over five treatments for prostate cancer with high-risk features after radical prostatectomy: MC1754.

Journal of Clinical Oncology | February 16, 2022 | Volume: 40 | Issue: 6_suppl | Pages: 248-248

10.1200/jco.2022.40.6_suppl.248

248 Background: Hypofractionated prostate cancer radiation has showed similar results in several prior phase III studies (PCG GU 003, PACE-B, and Hypo PC RT). However, prospective phase II-III clinical trial data testing 5 tx after prostatectomy is scarce. Methods: Between 2018 and 2019, 41 patients were treated after postprostatectomy for high risk features. 5 patients were treated adjuvantly, 36 for salvage including 8 with oligometastatic disease. Indications for adjuvant RT included a PSA < 0.2 and +margins, SVI, or EPE. Salvage RT was offered for PSA ≥0.2. Oligometastatic RT for patients with ≤5 RT targets. Staging included C11 PET for all cases. Total dose to the prostate bed was 30-32 Gy in 5tx QOD with IMRT, conebeam IGRT, and MRI registration. All salvage patients received ADT for 6 months and oligometastatic patients for 18 months. Dose to the metastatic sites was 30 in 5tx QOD. Of the 41 patients 8 also received SBRT to the sites of oligometastatic disease. We looked at clinical outcomes defining biochemical failure as a PSA > 0.2 after treatment, baseline adjusted CTC AE V5.0, baseline adjusted patient reported toxicities (PRO CTC AE), QOL (EPIC, PROMIS), and AUA was used for all cases. Results: Median follow up was 23 months (range 10-37). Pre-RT T stage was T2-T3b, with 47% being T3a-b; Pre RT Median PSA of 0.4 (range < 0.1-1.9); Median GS 8 (6-9); and (+) margins in 48.8%. Sites of oligometastatic disease radiated included the LN and bone. Treatment related AE were grade 0-1 in all cases, except for one patient with G2 GU incontinence. Overall QOL remained high during follow including Promis 10 overall, mental, and physical scores; urinary bother, irritative/obstructive, and AUA scores; bowel overall, bowel bother, and bowel function scores; and overall sexual, sexual function, and sexual bother scores remained at baseline levels during follow up. Only hormonal overall, hormonal function, and hormonal bother had lower scores at 3 months that recovered by 12 months in patients treated with ADT for 6 months and by 24 months in patients treated with ADT for 18 months. A total of 3 clinical failure have been seen; 2 patients with regional failures alone; and one with axial skeleton bony failures for 93% clinical control at median follow up of 23 months. All 3 patients with clinical failure were salvaged successfully with SBRT and all patients remain disease free at last follow up. A total 5 patients with raising PSAs alone have been seen. All patients have been re-staged with C11 PET. No failures in the prostate bed or previously radiated sites have been seen. Conclusions: Toxicity for RT over 5tx is lower than expected with only one case of grade 2 urinary incontinence. QOL scores remained high during follow up, minor changes in hormonal scores were seen during ADT, but recovered after. 30-32 Gy over 5 tx provided 100% control in radiated targets and metastatic sites. Clinical trial information: NCT03570827.
Per‐voxel constraints to minimize hot spots in linear energy transfer‐guided robust optimization for base of skull head and neck cancer patients in IMPT

Medical Physics | November 29, 2021 | Volume: 49 | Issue: 1 | Pages: 632-647

10.1002/mp.15384 | PMID 34843119

AbstractPurposeDue to the employment of quadratic programming using soft constraints to implement dose volume constraints and the “trial‐and‐error” procedure needed to achieve a clinically acceptable plan, conventional dose volume constraints (upper limit) are not adequately effective in controlling small and isolated hot spots in the dose/linear energy transfer (LET) distribution. Such hot spots can lead to adverse events. In order to mitigate the risk of brain necrosis, one of the most clinically significant adverse events in patients receiving intensity‐modulated proton therapy (IMPT) for base of skull (BOS) cancer, we propose per‐voxel constraints to minimize hot spots in LET‐guided robust optimization.Methods and materialsTen BOS cancer patients treated with IMPT were carefully selected by meeting one of the following conditions: (1) diagnosis of brain necrosis during follow‐up; and (2) considered high risk for brain necrosis by not meeting dose constraints to the brain. An optimizing structure (BrainOPT) and an evaluating structure (BrainROI) that both contained the aforementioned hot dose regions in the brain were generated for optimization and evaluation, respectively. Two plans were generated for every patient: one using conventional dose‐only robust optimization, the other using LET‐guided robust optimization. The impact of LET was integrated into the optimization via a term of extra biological dose (xBD). A novel optimization tool of per‐voxel constraints to control small and isolated hot spots in either the dose, LET, or combined (dose/LET) distribution was developed and used to minimize dose/LET hot spots of the selected structures. Indices from dose‐volume histogram (DVH) and xBD dose‐volume histogram (xBDVH) were used in the plan evaluation. A newly developed tool of the dose‐LET‐volume histogram (DLVH) was also adopted to illustrate the underlying mechanism. Wilcoxon signed‐rank test was used for statistical comparison of the DVH and xBDVH indices between the conventional dose‐only and the LET‐guided robustly optimized plans.ResultsPer‐voxel constraints effectively and efficiently minimized dose hot spots in both dose‐only and LET‐guided robust optimization and LET hot spots in LET‐guided robust optimization. Compared to the conventional dose‐only robust optimization, the LET‐guided robust optimization could generate plans with statistically lower xBD hot spots in BrainROI (VxBD,50 Gy[RBE], p = 0.009; VxBD,60 Gy[RBE], p = 0.025; xBD1cc, p = 0.017; xBD2cc, p = 0.022) with comparable dose coverage, dose hot spots in the target, and dose hot spots in BrainROI. DLVH analysis indicated that LET‐guided robust optimization could either reduce LET at the same dose level or redistribute high LET from high dose regions to low dose regions.ConclusionPer‐voxel constraint is a powerful tool to minimize dose/LET hot spots in IMPT. The LET‐guided robustly optimized plans outperformed the conventional dose‐only robustly optimized plans in terms of xBD hot spots control.
Technical Note: 4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma

Medical Physics | May 31, 2021 | Volume: 48 | Issue: 8 | Pages: 4636-4647

10.1002/mp.15003 | PMID 34058026

Purpose To compare the dosimetric performances of small‐spot three‐dimensional (3D) and four‐dimensional (4D) robustly optimized intensity‐modulated proton (IMPT) plans in the presence of uncertainties and interplay effect simultaneously for distal esophageal carcinoma. Method and Materials Thirteen (13) patients were selected and re‐planned with small‐spot ( ~ 2–6 mm) 3D and 4D robust optimization in IMPT, respectively. The internal clinical target volumes (CTV high3d , CTV low3d ) were used in 3D robust optimization. Different CTVs (CTV high4d , CTV low4d ) were generated by subtracting an inner margin of the motion amplitudes in three cardinal directions from the internal CTVs and used in 4D robust optimization. All patients were prescribed the same dose to CTVs (50 Gy[RBE] for CTV high3d /CTV high4d and 45 Gy[RBE] for CTV low3d /CTV low4d ). Dose–volume histogram (DVH) indices were calculated to assess plan quality. Comprehensive plan robustness evaluations that consisted of 300 perturbed scenarios (10 different motion patterns to consider irregular motion (sampled from a Gaussian distribution) and 30 different uncertainties scenarios (sampled from a 4D uniform distribution) combined), were performed to quantify robustness to uncertainties and interplay effect simultaneously. Wilcoxon signed‐rank test was used for statistical analysis. Results Compared to 3D robustly optimized plans, 4D robustly optimized plans had statistically improved target coverage and better sparing of lungs and heart (heart D mean , P = 0.001; heart V 30Gy[RBE] , P = 0.001) in the nominal scenario. 4D robustly optimized plans had better robustness in target dose coverage (CTV high4d V 100% , P = 0.002) and the protection of lungs and heart (heart D mean , P = 0.001; heart V 30Gy[RBE] , P = 0.001) when uncertainties and interplay effect were considered simultaneously. Conclusions Even with small spots in IMPT, 4D robust optimization outperformed 3D robust optimization in terms of normal tissue protection and robustness to uncertainties and interplay effect simultaneously. Our findings support the use of 4D robust optimization to treat distal esophageal carcinoma with small spots in IMPT.
Unplanned implant removal in locally advanced breast cancer

The Breast Journal | March 14, 2021 | Volume: 27 | Issue: 5 | Pages: 466-471

10.1111/tbj.14224 | PMID 33715231

Beam angle comparison for distal esophageal carcinoma patients treated with intensity‐modulated proton therapy

Journal of Applied Clinical Medical Physics | October 15, 2020 | Volume: 21 | Issue: 11 | Pages: 141-152

10.1002/acm2.13049 | PMID 33058523

Abstract Purpose To compare the dosimetric performances of intensity‐modulated proton therapy (IMPT) plans generated with two different beam angle configurations (the Right–Left oblique posterior beams and the Superior–Inferior oblique posterior beams) for the treatment of distal esophageal carcinoma in the presence of uncertainties and interplay effect. Methods and Materials Twenty patients’ IMPT plans were retrospectively selected, with 10 patients treated with the R‐L oblique posterior beams (Group R‐L) and the other 10 patients treated with the S‐I oblique posterior beams (Group S‐I). Patients in both groups were matched by their clinical target volumes (CTVs—high and low dose levels) and respiratory motion amplitudes. Dose‐volume‐histogram (DVH) indices were used to assess plan quality. DVH bandwidth was calculated to evaluate plan robustness. Interplay effect was quantified using four‐dimensional (4D) dynamic dose calculation with random respiratory starting phase of each fraction. Normal tissue complication probability (NTCP) for heart, liver, and lung was calculated, respectively, to estimate the clinical outcomes. Wilcoxon signed‐rank test was used for statistical comparison between the two groups. Results Compared with plans in Group R‐L, plans in Group S‐I resulted in significantly lower liver D mean and lung V 30Gy[RBE] with slightly higher but clinically acceptable spinal cord D max . Similar plan robustness was observed between the two groups. When interplay effect was considered, plans in Group S‐I performed statistically better for heart D mean and V 30Gy[RBE] , lung Dmean and V 5Gy[RBE] , and liver D mean , with slightly increased but clinically acceptable spinal cord D max . NTCP for liver was significantly better in Group S‐I. Conclusions IMPT plans in Group S‐I have better sparing of liver, heart, and lungs at the slight cost of spinal cord maximum dose protection, and are more interplay‐effect resilient compared to IMPT plans in Group R‐L. Our study supports the routine use of the S‐I oblique posterior beams for the treatments of distal esophageal carcinoma.
Intensity‐modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non‐small cell lung cancer

Medical Physics | September 22, 2020 | Volume: 47 | Issue: 11 | Pages: 5428-5440

10.1002/mp.14491 | PMID 32964474

Purpose Intensity‐modulated proton therapy (IMPT) is sensitive to uncertainties from patient setup and proton beam range, as well as interplay effect. In addition, respiratory motion may vary from cycle to cycle, and also from day to day. These uncertainties can severely degrade the original plan quality and potentially affect patient’s outcome. In this work, we developed a new tool to comprehensively consider the impact of all these uncertainties and provide plan robustness evaluation under them. Methods We developed a comprehensive plan robustness evaluation tool that considered both uncertainties from patient setup and proton beam range, as well as respiratory motion simultaneously. To mimic patients' respiratory motion, the time spent in each phase was randomly sampled based on patient‐specific breathing pattern parameters as acquired during the four‐dimensional (4D)‐computed tomography (CT) simulation. Spots were then assigned to one specific phase according to the temporal relationship between spot delivery sequence and patients’ respiratory motion. Dose in each phase was calculated by summing contributions from all the spots delivered in that phase. The final 4D dynamic dose was obtained by deforming all doses in each phase to the maximum exhalation phase. Three hundred (300) scenarios (10 different breathing patterns with 30 different setup and range uncertainty scenario combinations) were calculated for each plan. The dose‐volume histograms (DVHs) band method was used to assess plan robustness. Benchmarking the tool as an application’s example, we compared plan robustness under both three‐dimensional (3D) and 4D robustly optimized IMPT plans for 10 nonrandomly selected patients with non‐small cell lung cancer. Results The developed comprehensive plan robustness tool had been successfully applied to compare the plan robustness between 3D and 4D robustly optimized IMPT plans for 10 lung cancer patients. In the presence of interplay effect with uncertainties considered simultaneously, 4D robustly optimized plans provided significantly better CTV coverage (D 95% , P = 0.002), CTV homogeneity (D 5% ‐D 95% , P = 0.002) with less target hot spots (D 5% , P = 0.002), and target coverage robustness (CTV D 95% bandwidth, P = 0.004) compared to 3D robustly optimized plans. Superior dose sparing of normal lung (lung D mean , P = 0.020) favoring 4D plans and comparable normal tissue sparing including esophagus, heart, and spinal cord for both 3D and 4D plans were observed. The calculation time for all patients included in this study was 11.4 ± 2.6 min. Conclusion A comprehensive plan robustness evaluation tool was successfully developed and benchmarked for plan robustness evaluation in the presence of interplay effect, setup and range uncertainties. The very high efficiency of this tool marks its clinical adaptation, highly practical and versatile nature, including possible real‐time intra‐fractional interplay effect evaluation as a potential application for future use.