Citations 31

Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads

Pacing and Clinical Electrophysiology | May 25, 2018 | Volume: 41 | Issue: 8 | Pages: 912-919

10.1111/pace.13388 | PMID 29799618

AbstractBackgroundQuadripolar left ventricular (LV) leads provide a more optimal pacing configuration for cardiac resynchronization therapy (CRT) than conventional bipolar leads. The objective of this study is to determine the clinical outcomes of CRT using quadripolar leads.MethodsThis study included 516 CRT patients who received bipolar LV leads (n = 278) or quadripolar LV leads (n = 238) from January 2013 to June 2016. Data were retrospectively collected from a prospective CRT database and electronic health records. CRT response to CRT was defined as >5% improvement in the LV ejection fraction (LVEF) from baseline. Baseline characteristics and outcomes were compared between groups.ResultsNew York Heart Association Functional Classification and LVEF significantly improved in the quadripolar and bipolar groups after CRT. There was no difference in the all‐cause mortality rate. The implant success rate was significantly higher in the quadripolar group (100% vs 97.8%; P = 0.02). Quadripolar lead placement was an independent predictor of CRT response at 12 months (hazard ratio, 0.76; 95% confidence interval, 0.58–0.98; P = 0.04). The rate of LV lead–related complications requiring invasive lead revision or abandonment was significantly higher in the bipolar group (11.2% vs 4.6%; P = 0.007).ConclusionsQuadripolar leads achieve similar CRT outcomes as bipolar LV leads but with a higher implant success rate and fewer procedure‐related complications.
Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 | PMID 28543771

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Impact of a Care Process Model on Management of Cardiovascular Implantable Electronic Device Infections

Open Forum Infectious Diseases | February 3, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.811

Impact of a Primary Inpatient Electrophysiology Service on Cardiovascular Implantable Electronic Device Infections in a Tertiary Care Hospital

Open Forum Infectious Diseases | February 2, 2017 | Volume: 3 | Issue: suppl_1 | Pages: No page available

10.1093/ofid/ofw172.810

Single-Coil Defibrillator Leads Yield Satisfactory Defibrillation Safety Margin in Hypertrophic Cardiomyopathy

Circulation Journal | August 25, 2016 | Volume: 80 | Issue: 10 | Pages: 2199-2203

10.1253/circj.cj-16-0428 | PMID 27568735

Entrapment of a Pacing Lead within a Chiari Network: Utility of Intracardiac Echo and a Laser Sheath

Pacing and Clinical Electrophysiology | February 13, 2016 | Volume: 39 | Issue: 6 | Pages: 620-622

10.1111/pace.12828 | PMID 26873294

Outcomes and Complications of Lead Removal: Can We Establish a Risk Stratification Schema for a Collaborative and Effective Approach?

Pacing and Clinical Electrophysiology | August 21, 2015 | Volume: 38 | Issue: 12 | Pages: 1439-1447

10.1111/pace.12736 | PMID 26293652

Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Echocardiographic Diagnosis of Constrictive Pericarditis

Circulation: Cardiovascular Imaging | March 15, 2014 | Volume: 7 | Issue: 3 | Pages: 526-534

10.1161/circimaging.113.001613 | PMID 24633783

Background— Constrictive pericarditis is a potentially reversible cause of heart failure that may be difficult to differentiate from restrictive myocardial disease and severe tricuspid regurgitation. Echocardiography provides an important opportunity to evaluate for constrictive pericarditis, and definite diagnostic criteria are needed. Methods and Results— Patients with surgically confirmed constrictive pericarditis (n=130) at Mayo Clinic (2008–2010) were compared with patients (n=36) diagnosed with restrictive myocardial disease or severe tricuspid regurgitation after constrictive pericarditis was considered but ruled out. Comprehensive echocardiograms were reviewed in blinded fashion. Five principal echocardiographic variables were selected based on prior studies and potential for clinical use: (1) respiration-related ventricular septal shift, (2) variation in mitral inflow E velocity, (3) medial mitral annular e' velocity, (4) ratio of medial mitral annular e' to lateral e', and (5) hepatic vein expiratory diastolic reversal ratio. All 5 principal variables differed significantly between the groups. In patients with atrial fibrillation or flutter (n=29), all but mitral inflow velocity remained significantly different. Three variables were independently associated with constrictive pericarditis: (1) ventricular septal shift, (2) medial mitral e', and (3) hepatic vein expiratory diastolic reversal ratio. The presence of ventricular septal shift in combination with either medial e'≥9 cm/s or hepatic vein expiratory diastolic reversal ratio ≥0.79 corresponded to a desirable combination of sensitivity (87%) and specificity (91%). The specificity increased to 97% when all 3 factors were present, but the sensitivity decreased to 64%. Conclusions— Echocardiography allows differentiation of constrictive pericarditis from restrictive myocardial disease and severe tricuspid regurgitation. Respiration-related ventricular septal shift, preserved or increased medial mitral annular e' velocity, and prominent hepatic vein expiratory diastolic flow reversals are independently associated with the diagnosis of constrictive pericarditis.
Frequency of nerve fiber degeneration of peripheral motor and sensory neurons in amyotrophic lateral sclerosis

Neurology | May 13, 2012 | Volume: 25 | Issue: 8 | Pages: 781-781

10.1212/wnl.25.8.781 | PMID 1171412