Objectives: Assessment of carotid disease is most commonly performed with duplex ultrasonography (DUS). Measures of plaque area and tissue composition from DUS images may identify patients at risk for future neurologic events, and may assess the effects of vascular risk-factor modification (by measuring change in plaque area and/or tissue constituents). We quantified plaque area and tissue constituents from DUS images of CREST-2 participants at baseline and correlated them with their baseline vascular risk factors. Methods: CREST-2 consists of two multicenter, randomized trials in patients with asymptomatic ≥70% carotid stenosis comparing intensive medical management (IMM) plus endarterectomy or stenting vs IMM alone. Baseline B-mode DUS images from 500 patients underwent manual plaque outlining and automatic pixel brightness assessment. Plaque area, grayscale median (GSM), Gray-Weale score for heterogeneity, and areas for intraplaque hemorrhage and lipid were the output parameters. We computed the parameter estimates (95% confidence intervals) for baseline patient characteristics (age, sex, race, diabetes, smoking, BMI, blood pressure and LDL levels) versus plaque characteristics. Results: High-risk plaque features (larger plaque area, lower GSM , lower Gray-Weale scores, or larger areas of hemorrhage and lipid) were present in older patients, males, and those with elevated diastolic blood pressure and LDL levels (Table). Conclusions: In a randomized trial of asymptomatic patients with high-grade carotid stenosis, DUS-based computation of plaque geometry and tissue composition is feasible. Elevated diastolic blood pressure and LDL levels at baseline are associated with high-risk plaque characteristics. These novel findings identify potentially modifiable targets for aggressive treatment to reduce stroke-risk in patients with carotid stenosis.
Cerebral microbleeds
Neurology | December 19, 2018 | Volume: 92 | Issue: 3 | Pages: No page available
Objective: Aneurysm growth is considered predictive of future rupture of intracranial aneurysms. However, it is still unknown how accurately neuroradiologists can reliably detect incremental aneurysm growth using clinical magnetic resonance imaging (MRI) imaging. The purpose of this study is to assess the agreement rate of detecting aneurysm enlargement using generally used MRI imaging modalities. Methods: Three silicone flow phantom models each with eight aneurysms of various sizes in different sites were used in this study. The aneurysm models were identical except for an incremental increase in size of the 8 aneurysms ranging from 0.4mm to 2mm. The phantoms were imaged on 1.5 tesla (T) and 3T MRI units with both time-of-flight (TOF) and contrast enhanced magnetic resonance angiography (MRA). Three independent expert neuroradiologists measured the aneurysms in a blinded fashion utilizing different measurement approaches. The individual and agreement rate among the three experts in detecting aneurysm enlargement were calculated. Results: The average detection rate of any increase in any aneurysmal dimensions was 95.7%. The detection rate for the three readers (A, B and C) was 98.0%, 96.6% and 92.7%, respectively ( P =0.22). The detection rate in each MRI modality was 91.3% using 1.5 T TOF, 97.2% using 1.5T gadolinium (Gad), 95.8% using 3.0T TOF and 97.2% using 3.0T Gad ( P =0.31). As the incremental enlargement value increased, the detection rate for aneurysm enlargement increased. Use of Gad in 1.5T improved the detection rate in small incremental enlargement (e.g. 0.4 - 1mm) of the aneurysm ( P =0.04). The locations of the aneurysms also affected detection rate for aneurysm enlargement ( P <0.0001). Conclusions: The detection rate and interobserver agreement was very high for aneurysm enlargement of 0.4mm to 2 mm. Detection rate of any increase in any aneurysmal dimensions did not depend on the choice of MRI imaging modalities and measurement protocols.
Improving apparent diffusion coefficient accuracy on a compact 3T MRI scanner using gradient nonlinearity correction
Journal of Magnetic Resonance Imaging | September 26, 2018 | Volume: 48 | Issue: 6 | Pages: 1498-1507
BackgroundGradient nonlinearity (GNL) leads to biased apparent diffusion coefficients (ADCs) in diffusion‐weighted imaging. A gradient nonlinearity correction (GNLC) method has been developed for whole body systems, but is yet to be tested for the new compact 3T (C3T) scanner, which exhibits more complex GNL due to its asymmetrical design.PurposeTo assess the improvement of ADC quantification with GNLC for the C3T scanner.Study TypePhantom measurements and retrospective analysis of patient data.Phantom/SubjectsA diffusion quality control phantom with vials containing 0–30% polyvinylpyrrolidone in water was used. For in vivo data, 12 patient exams were analyzed (median age, 33).Field Strength/SequenceImaging was performed on the C3T and two commercial 3T scanners. A clinical DWI (repetition time [TR] = 10,000 msec, echo time [TE] = minimum, b = 1000 s/mm2) sequence was used for phantom imaging and 10 patient cases and a clinical DTI (TR = 6000–10,000 msec, TE = minimum, b = 1000 s/mm2) sequence was used for two patient cases.AssessmentThe 0% vial was measured along three orthogonal axes, and at two different temperatures. The ADC for each concentration was compared between the C3T and two whole‐body scanners. Cerebrospinal fluid and white matter ADCs were quantified for each patient and compared to values in literature.Statistical TestsPaired t‐test and two‐way analysis of variance (ANOVA).ResultsFor all PVP concentrations, the corrected ADC was within 2.5% of the reference ADC. On average, the ADC of cerebrospinal fluid and white matter post‐GNLC were within 1% and 6%, respectively, of values reported in the literature and were significantly different from the uncorrected data (P < 0.05).Data ConclusionThis study demonstrated that GNL effects were more severe for the C3T due to the asymmetric gradient design, but our implementation of a GNLC compensated for these effects, resulting in ADC values that are in good agreement with values from the literature.Level of Evidence: 4Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;48:1498–1507
Carotid revascularization and medical management for asymptomatic carotid stenosis – Hemodynamics (CREST-H): Study design and rationale
International Journal of Stroke | August 22, 2018 | Volume: 13 | Issue: 9 | Pages: 985-991
Rationale For patients with asymptomatic high-grade carotid stenosis, clinical investigations have focused on preventing cerebral infarction, yet stenosis that reduces cerebral blood flow may independently impair cognition. Whether revascularization of a hemodynamically significant carotid stenosis can alter the course of cognitive decline has never been investigated in the context of a randomized clinical trial. Hypothesis Among patients randomized in the Carotid Revascularization and Medical Management for Asymptomatic Carotid Stenosis (CREST-2) trials, the magnitude of treatment differences (revascularization versus medical management alone) with regard to cognition will differ between those with flow impairment compared to those without flow impairment. Sample size We will enroll approximately 500 patients from CREST-2, of which we anticipate 100 will have hemodynamic impairment. We estimate 93% power to detect a clinically meaningful treatment difference of 0.5 SD. Methods and design We will use perfusion-weighted magnetic resonance imaging to stratify by hemodynamic status. Linear regression will compare treatment differences, controlling for baseline cognitive status, age, depression, prior cerebral infarcts, silent infarction, white matter hyperintensity volume, and cerebral microbleeds. Study outcomes The primary outcome is change in cognition at one year. Secondary outcomes include silent infarction, change in white matter hyperintensity volume, number of cerebral microbleeds, and cortical thickness over one year. Discussion If cognitive impairment can be shown to be reversible by revascularization, then we can redefine “symptomatic carotid stenosis” to include cognitive impairment and identify a new population of patients likely to benefit from revascularization. Trial Registration US National Institutes of Health (NIH) clinicaltrials.gov NCT03121209
In vivo characterization of 3D skull and brain motion during dynamic head vibration using magnetic resonance elastography
Magnetic Resonance in Medicine | May 18, 2018 | Volume: 80 | Issue: 6 | Pages: 2573-2585
PurposeTo introduce newly developed MR elastography (MRE)‐based dual‐saturation imaging and dual‐sensitivity motion encoding schemes to directly measure in vivo skull–brain motion, and to study the skull–brain coupling in volunteers with these approaches.MethodsSix volunteers were scanned with a high‐performance compact 3T‐MRI scanner. The skull–brain MRE images were obtained with a dual‐saturation imaging where the skull and brain motion were acquired with fat‐ and water‐suppression scans, respectively. A dual‐sensitivity motion encoding scheme was applied to estimate the heavily wrapped phase in skull by the simultaneous acquisition of both low‐ and high‐sensitivity phase during a single MRE exam. The low‐sensitivity phase was used to guide unwrapping of the high‐sensitivity phase. The amplitude and temporal phase delay of the rigid‐body motion between the skull and brain was measured, and the skull–brain interface was visualized by slip interface imaging (SII).ResultsBoth skull and brain motion can be successfully acquired and unwrapped. The skull–brain motion analysis demonstrated the motion transmission from the skull to the brain is attenuated in amplitude and delayed. However, this attenuation (%) and delay (rad) were considerably greater with rotation (59 ± 7%, 0.68 ± 0.14 rad) than with translation (92 ± 5%, 0.04 ± 0.02 rad). With SII the skull–brain slip interface was not completely evident, and the slip pattern was spatially heterogeneous.ConclusionThis study provides a framework for acquiring in vivo voxel‐based skull and brain displacement using MRE that can be used to characterize the skull–brain coupling system for understanding of mechanical brain protection mechanisms, which has potential to facilitate risk management for future injury.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245
PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Accuracy of detecting enlargement of aneurysms using different MRI modalities and measurement protocols
Journal of Neurosurgery | March 9, 2018 | Volume: 130 | Issue: 2 | Pages: 559-565
OBJECTIVEAneurysm growth is considered predictive of future rupture of intracranial aneurysms. However, how accurately neuroradiologists can reliably detect incremental aneurysm growth using clinical MRI is still unknown. The purpose of this study was to assess the agreement rate of detecting aneurysm enlargement employing generally used MRI modalities.METHODSThree silicone flow phantom models, each with 8 aneurysms of various sizes at different sites, were used in this study. The aneurysm models were identical except for an incremental increase in the sizes of the 8 aneurysms, which ranged from 0.4 mm to 2 mm. The phantoms were imaged on 1.5-T and 3-T MRI units with both time-of-flight (TOF) and contrast-enhanced MR angiography. Three independent expert neuroradiologists measured the aneurysms in a blinded manner using different measurement approaches. The individual and agreement detection rates of aneurysm enlargement among the 3 experts were calculated.RESULTSThe mean detection rate of any increase in any aneurysmal dimension was 95.7%. The detection rates of the 3 observers (observers A, B, and C) were 98.0%, 96.6%, and 92.7%, respectively (p = 0.22). The detection rates of each MRI modality were 91.3% using 1.5-T TOF, 97.2% using 1.5-T with Gd, 95.8% using 3.0-T TOF, and 97.2% using 3.0-T with Gd (p = 0.31). On the other hand, the mean detection rate for aneurysm enlargement was 54.8%. Specifically, the detection rates of observers A, B, and C were 49.0%, 46.1%, and 66.7%, respectively (p = 0.009). As the incremental enlargement value increased, the detection rate for aneurysm enlargement increased. The use of 1.5-T Gd improved the detection rate for small incremental enlargement (e.g., 0.4–1 mm) of the aneurysm (p = 0.04). The location of the aneurysm also affected the detection rate for aneurysm enlargement (p < 0.0001).CONCLUSIONSThe detection rate and interobserver agreement were very high for aneurysm enlargement of 0.4–2 mm. The detection rate for at least 1 increase in any aneurysm dimension did not depend on the choice of MRI modality or measurement protocol. Use of Gd improved the accuracy of measurement. Aneurysm location may influence the accuracy of detecting enlargement.
Time‐resolved contrast‐enhanced MR angiography with single‐echo Dixon fat suppression
Magnetic Resonance in Medicine | February 28, 2018 | Volume: 80 | Issue: 4 | Pages: 1556-1567
PurposeDixon‐based fat suppression has recently gained interest for dynamic contrast‐enhanced MRI, but multi‐echo techniques require longer scan times and reduce temporal resolution compared to single‐echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single‐echo Dixon imaging with high spatial and temporal resolution.Theory and MethodsReal‐valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat‐water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8.ResultsSingle‐echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast‐enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single‐echo Dixon work.ConclusionTime‐resolved contrast‐enhanced MRI with single‐echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time‐subtraction methods.