TURBINE‐MRE: A 3D hybrid radial‐Cartesian EPI acquisition for MR elastography

Magnetic Resonance in Medicine | August 1, 2020 | Volume: 85 | Issue: 2 | Pages: 945-952

10.1002/mrm.28445 | PMID 32738084

PurposeTo develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain.MethodThe proposed 3D TURBINE‐MRE is based on a spoiled gradient‐echo MRE sequence with the EPI readout radially rotating about the phase‐encoding axis to sample a full 3D k‐space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32‐channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin‐echo (SE) EPI‐MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE‐MRE images were off‐line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE‐EPI‐MRE and TURBINE‐MRE.ResultsThe 3D wave‐field images and the generated stiffness maps were comparable between TURBINE‐MRE and standard SE‐EPI‐MRE for the phantom and the volunteers. The Bland–Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943.ConclusionWe demonstrated the feasibility of the new TURBINE‐MRE sequence for acquiring the desired 3D wave‐field data and stiffness maps in a phantom and in‐vivo brains. This pilot study encourages further exploration of TURBINE‐MRE for functional MRE, free‐breathing abdominal MRE, and cardiac MRE applications.
Safety and efficacy of (+)‐epicatechin in subjects with Friedreich's ataxia: A phase II , open‐label, prospective study

Journal of Inherited Metabolic Disease | July 17, 2020 | Volume: 44 | Issue: 2 | Pages: 502-514

10.1002/jimd.12285 | PMID 32677106

Abstract Background (+)‐Epicatechin (EPI) induces mitochondrial biogenesis and antioxidant metabolism in muscle fibers and neurons. We aimed to evaluate safety and efficacy of (+)‐EPI in pediatric subjects with Friedreich's ataxia (FRDA). Methods This was a phase II, open‐label, baseline‐controlled single‐center trial including 10 participants ages 10 to 22 with confirmed FA diagnosis. (+)‐EPI was administered orally at 75 mg/d for 24 weeks, with escalation to 150 mg/d at 12 weeks for subjects not showing improvement of neuromuscular, neurological or cardiac endpoints. Neurological endpoints were change from baseline in Friedreich's Ataxia Rating Scale (FARS) and 8‐m timed walk. Cardiac endpoints were changes from baseline in left ventricular (LV) structure and function by cardiac magnetic resonance imaging (MRI) and echocardiogram, changes in cardiac electrophysiology, and changes in biomarkers for heart failure and hypertrophy. Results Mean FARS/modified (m)FARS scores showed nonstatistically significant improvement by both group and individual analysis. FARS/mFARS scores improved in 5/9 subjects (56%), 8‐m walk in 3/9 (33%), 9‐peg hole test in 6/10 (60%). LV mass index by cardiac MRI was significantly reduced at 12 weeks ( P = .045), and was improved in 7/10 (70%) subjects at 24 weeks. Mean LV ejection fraction was increased at 24 weeks ( P = .008) compared to baseline. Mean maximal septal thickness by echocardiography was increased at 24 weeks ( P = .031). There were no serious adverse events. Conclusion (+)‐EPI was well tolerated over 24 weeks at up to 150 mg/d. Improvement was observed in cardiac structure and function in subset of subjects with FRDA without statistically significant improvement in primary neurological outcomes. Synopsis A (+)‐epicatechin showed improvement of cardiac function, nonsignificant reduction of FARS/mFARS scores, and sustained significant upregulation of muscle‐regeneration biomarker follistatin.
MRI and tractography techniques to localize the ventral intermediate nucleus and dentatorubrothalamic tract for deep brain stimulation and MR-guided focused ultrasound: a narrative review and update

Neurosurgical Focus | July 1, 2020 | Volume: 49 | Issue: 1 | Pages: E8

10.3171/2020.4.focus20170 | PMID 32610293

The thalamic ventral intermediate nucleus (VIM) can be targeted for treatment of tremor by several procedures, including deep brain stimulation (DBS) and, more recently, MR-guided focused ultrasound (MRgFUS). To date, such targeting has relied predominantly on coordinate-based or atlas-based techniques rather than directly targeting the VIM based on imaging features. While general regional differences of features within the thalamus and some related white matter tracts can be distinguished with conventional imaging techniques, internal nuclei such as the VIM are not discretely visualized. Advanced imaging methods such as quantitative susceptibility mapping (QSM) and fast gray matter acquisition T1 inversion recovery (FGATIR) MRI and high-field MRI pulse sequences that improve the ability to image the VIM region are emerging but have not yet been shown to have reliability and accuracy to serve as the primary method of VIM targeting. Currently, the most promising imaging approach to directly identify the VIM region for clinical purposes is MR diffusion tractography. In this review and update, the capabilities and limitations of conventional and emerging advanced methods for evaluation of internal thalamic anatomy are briefly reviewed. The basic principles of tractography most relevant to VIM targeting are provided for familiarization. Next, the key literature to date addressing applications of DTI and tractography for DBS and MRgFUS is summarized, emphasizing use of direct targeting. This literature includes 1-tract (dentatorubrothalamic tract [DRT]), 2-tract (pyramidal and somatosensory), and 3-tract (DRT, pyramidal, and somatosensory) approaches to VIM region localization through tractography. The authors introduce a 3-tract technique used at their institution, illustrating the oblique curved course of the DRT within the inferior thalamus as well as the orientation and relationship of the white matter tracts in the axial plane. The utility of this 3-tract tractography approach to facilitate VIM localization is illustrated with case examples of variable VIM location, targeting superior to the anterior commissure–posterior commissure plane, and treatment in the setting of pathologic derangement of thalamic anatomy. Finally, concepts demonstrated with these case examples and from the prior literature are synthesized to highlight several potential advantages of tractography for VIM region targeting.
Identification of Normal Pressure Hydrocephalus by Disease-Specific Patterns of Brain Stiffness and Damping Ratio

Investigative Radiology | February 14, 2020 | Volume: 55 | Issue: 4 | Pages: 200-208

10.1097/rli.0000000000000630 | PMID 32058331

ObjectivesThe aim of this study was to perform a whole-brain analysis of alterations in brain mechanical properties due to normal pressure hydrocephalus (NPH).Materials and MethodsMagnetic resonance elastography (MRE) examinations were performed on 85 participants, including 44 cognitively unimpaired controls, 33 with NPH, and 8 who were amyloid-positive with Alzheimer clinical syndrome. A custom neural network inversion was used to estimate stiffness and damping ratio from patches of displacement data, accounting for edges by training the network to estimate the mechanical properties in the presence of missing data. This learned inversion was first compared with a standard analytical approach in simulation experiments and then applied to the in vivo MRE measurements. The effect of NPH on the mechanical properties was then assessed by voxel-wise modeling of the stiffness and damping ratio maps. Finally, a pattern analysis was performed on each individual's mechanical property maps by computing the correlation between each person's maps with the expected NPH effect. These features were used to fit a classifier and assess diagnostic accuracy.ResultsThe voxel-wise analysis of the in vivo mechanical property maps revealed a unique pattern in participants with NPH, including a concentric pattern of stiffening near the dural surface and softening near the ventricles, as well as decreased damping ratio predominantly in superior regions of the white matter (family-wise error correctedP< 0.05 at cluster level). The pattern of viscoelastic changes in each participant predicted NPH status in this cohort, separating participants with NPH from the control and the amyloid-positive with Alzheimer clinical syndrome groups, with areas under the receiver operating characteristic curve of 0.999 and 1, respectively.ConclusionsThis study provides motivation for further development of the neural network inversion framework and demonstrates the potential of MRE as a novel tool to diagnose NPH and provide a window into its pathogenesis.
Cerebral microbleed incidence, relationship to amyloid burden

Neurology | December 5, 2019 | Volume: 94 | Issue: 2 | Pages: No page available

10.1212/wnl.0000000000008735 | PMID 31801832

The effect of spiral trajectory correction on pseudo‐continuous arterial spin labeling with high‐performance gradients on a compact 3T scanner

Magnetic Resonance in Medicine | December 4, 2019 | Volume: 84 | Issue: 1 | Pages: 192-205

10.1002/mrm.28110 | PMID 31799747

PurposeTo demonstrate the feasibility of pseudo‐continuous arterial‐spin–labeled (pCASL) imaging with 3D fast‐spin‐echo stack‐of‐spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy‐current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion‐related images with high‐performance gradients (80 mT/m, 700T/m/s) of the C3T.MethodsTo track eddy‐current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density‐compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion‐weighted (ΔM) images and proton‐density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers.ResultsBlurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal‐to‐noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s.ConclusionEddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral‐readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high‐performance gradients.
Cerebrospinal fluid dynamics disorders

Neurology | November 13, 2019 | Volume: 93 | Issue: 24 | Pages: No page available

10.1212/wnl.0000000000008616 | PMID 31719134

Presymptomatic Screening for Intracranial Aneurysms in Patients with Autosomal Dominant Polycystic Kidney Disease

Clinical Journal of the American Society of Nephrology | July 30, 2019 | Volume: 14 | Issue: 8 | Pages: 1151-1160

10.2215/cjn.14691218 | PMID 31362991

Background and objectives Intracranial aneurysm rupture is the most devastating complication of autosomal dominant polycystic kidney disease. Whether selective or widespread intracranial aneurysm screening is indicated remains controversial. Design, setting, participants & measurements Records of 3010 patients with autosomal dominant polycystic kidney disease evaluated at the Mayo Clinic between 1989 and 2017 were reviewed. Those who had presymptomatic magnetic resonance angiography screening were included. Results Ninety-four intracranial aneurysms were diagnosed in 75 of 812 (9%) patients who underwent magnetic resonance angiography screening. Sex, age, race, and genotype were similar in the groups with and without aneurysms; hypertension and history of smoking were more frequent in the aneurysm group. Twenty-nine percent of patients with aneurysms compared with 11% of those without aneurysms had a family history of subarachnoid hemorrhage ( P <0.001). Most aneurysms were small (median diameter =4 mm; range, 2–12 mm); 85% were in the anterior circulation. During a total imaging follow-up of 469 patient-years, de novo intracranial aneurysms were detected in five patients; eight intracranial aneurysms grew (median =2 mm; range, 1–3 mm). During a total clinical follow-up of 668 patient-years, seven patients had preemptive clipping or coil embolization; no intracranial aneurysms ruptured. During a total clinical follow-up of 4783 patient-years in 737 patients with no intracranial aneurysm detected on the first magnetic resonance angiography screening, two patients had an intracranial aneurysm rupture (0.04 per 100 person-years; 95% confidence interval, 0 to 0.10). The rate of intracranial aneurysm rupture in large clinical trials of autosomal dominant polycystic kidney disease was 0.04 per 100 patient-years (95% confidence interval, 0.01 to 0.06). Conclusions Intracranial aneurysms were detected by presymptomatic screening in 9% of patients with autosomal dominant polycystic kidney disease, more frequently in those with familial history of subarachnoid hemorrhage, hypertension, or smoking. None of the patients with and two of the patients without aneurysm detection on screening suffered aneurysmal ruptures. The overall rupture rate in our autosomal dominant polycystic kidney disease cohort was approximately five times higher than that in the general population.
Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients

Journal of Magnetic Resonance Imaging | May 21, 2019 | Volume: 51 | Issue: 1 | Pages: 296-310

10.1002/jmri.26792 | PMID 31111581

BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.
Abstract TP582: A Multi-Site Validation of MRI Biomarkers of Vascular Leak and Hemorrhage for Forthcoming Clinical Trials

Stroke | January 30, 2019 | Volume: 50 | Issue: Suppl_1 | Pages: No page available

10.1161/str.50.suppl_1.tp582

Background: Cerebral cavernous malformation is a genetic neurovascular disorder causing aberrant angiogenesis and lesion development within capillary beds. Lesions exhibit impaired endothelial barrier function, causing blood-brain barrier leakage and hemorrhage. Quantitative MRI biomarkers (dynamic contrast-enhanced quantitative permeability (DCEQP) and quantitative susceptibility mapping (QSM)) have been shown to correlate with CCM disease progression as measures of barrier leakage and hemorrhagic iron deposition, and there is interest in utilizing these biomarkers as endpoints in clinical trials. However, their consistencies across multiple platforms and institutions has not yet been rigorously verified. Materials and Methods: Instruments used were a 3T Philips Ingenia at University of Chicago and a 3T Siemens Prisma at Northwestern University. QSM was assessed by five balloons filled with varying concentrations of MultiHance, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8, surrounded by an agarose gel. Permeability was assessed by the injection of a bolus of MultiHance through a coiled hose inside a water-filled shell, and the consistency of the peak-to-peak ratio of the curves at the input and output was measured. Each biomarker was assessed by accuracy (to expected values, Pearson correlation), precision (between repeated measurements, paired t-test), and reproducibility (between instruments, paired t-test). Results: QSM measured with an accuracy of r 2 = 0.997 on the Philips Achieva and r 2 = 0.999 on the Siemens Prisma. Each scanner had adequate precision between measurements, showing no significant difference by a paired t-test (p = 0.66 Achieva, p = 0.45 Prisma), and the reproducibility between scanners also showed no significant difference (p = 0.89). The peak-to-peak ratio on DCEQP scans was accurate (r 2 = 0.998), precise between measurements (p = 0.54), and repeatable between instruments (p = 0.49). Conclusion: Quantitative imaging biomarkers DCEQP and QSM are accurate, consistent across multiple measurements, and between platforms and will be useful for future clinical trials in CCM.