Back to Authors

Fernández, Julio M.

A5105467573 | I1330342723

Mayo Clinic

Mayo Clinic

Citations 5

Unzipping a Membrane

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 9 | Pages: 3-7

10.1017/s1551929500059368

Abstract The atomic force microscope (AFM) is well known for its outstanding spatial resolution, but it is becoming increasingly useful as the instrument for force spectroscopy. In the force spectroscopy mode, the AFM can measure tiny tension forces, in the piconewton (pN) range. Daniel Müller, Wolfgang Baurmeister, and Andreas Engel have used the AFM in both the imaging and force spectroscopy modes to pull proteins out of membranes in a controlled fashion. Müller et al. used Deinococcus radiodurans, a bacterium best known for its high resistance to radiation (as its Genus name implies), as their test subject. They extracted a highly regular membrane from the bacterium, the hexagonally packed intermediate (HPl) layer. They mounted the HPI on mica, so that the hydrophilic outer surface of the HPI adsorbed strongly to the mica, exposing the hydrophobic inner surface to the silicon nitride AFM stylus.
The Secretory Granule Matrix: A Fast-Acting Smart Polymer

Science | October 5, 2006 | Volume: 259 | Issue: 5097 | Pages: 963-965

10.1126/science.8438154 | PMID 8438154

The secretory granule matrix is a miniature biopolymer that consists of a charged polymer network that traps peptides and transmitters when it condenses and releases them on exocytotic decondensation. Models of exocytotic fusion have treated this matrix as a short circuit and have neglected its electrical contributions. This matrix responded to negative voltages by swelling, which was accompanied by a large increase in conductance, and to positive voltages by condensing. Thus, the matrix resembled a diode. The swollen matrix exerted large pressures on the order of 12 bar. The responses took place within milliseconds of the application of the electric field. These findings suggest that matrix decondensation, and therefore product release, is controlled by potential gradients.
Simultaneous atomic force microscope and fluorescence measurements of protein unfolding using a calibrated evanescent wave

Proceedings of the National Academy of Sciences | August 23, 2004 | Volume: 101 | Issue: 35 | Pages: 12882-12886

10.1073/pnas.0403534101 | PMID 15326308

Fluorescence techniques for monitoring single-molecule dynamics in the vertical dimension currently do not exist. Here we use an atomic force microscope to calibrate the distance-dependent intensity decay of an evanescent wave. The measured evanescent wave transfer function was then used to convert the vertical motions of a fluorescent particle into displacement (SD = <1 nm). We demonstrate the use of the calibrated evanescent wave to resolve the 20.1 ± 0.5-nm step increases in the length of the small protein ubiquitin during forced unfolding. The experiments that we report here make an important contribution to fluorescence microscopy by demonstrating the unambiguous optical tracking of a single molecule with a resolution comparable to that of an atomic force microscope.
Reversible Unfolding of Individual Titin Immunoglobulin Domains by AFM

Science | July 27, 2002 | Volume: 276 | Issue: 5315 | Pages: 1109-1112

10.1126/science.276.5315.1109 | PMID 9148804

Single-molecule atomic force microscopy (AFM) was used to investigate the mechanical properties of titin, the giant sarcomeric protein of striated muscle. Individual titin molecules were repeatedly stretched, and the applied force was recorded as a function of the elongation. At large extensions, the restoring force exhibited a sawtoothlike pattern, with a periodicity that varied between 25 and 28 nanometers. Measurements of recombinant titin immunoglobulin segments of two different lengths exhibited the same pattern and allowed attribution of the discontinuities to the unfolding of individual immunoglobulin domains. The forces required to unfold individual domains ranged from 150 to 300 piconewtons and depended on the pulling speed. Upon relaxation, refolding of immunoglobulin domains was observed.
Atomic levers control pyranose ring conformations

Proceedings of the National Academy of Sciences | July 26, 2002 | Volume: 96 | Issue: 14 | Pages: 7894-7898

10.1073/pnas.96.14.7894 | PMID 10393918

Atomic force microscope manipulations of single polysaccharide molecules have recently expanded conformational chemistry to include force-driven transitions between the chair and boat conformers of the pyranose ring structure. We now expand these observations to include chair inversion, a common phenomenon in the conformational chemistry of six-membered ring molecules. We demonstrate that by stretching single pectin molecules (1 → 4-linked α- d -galactouronic acid polymer), we could change the pyranose ring conformation from a chair to a boat and then to an inverted chair in a clearly resolved two-step conversion: 4 C 1 ⇄ boat ⇄ 1 C 4 . The two-step extension of the distance between the glycosidic oxygen atoms O 1 and O 4 determined by atomic force microscope manipulations is corroborated by ab initio calculations of the increase in length of the residue vector O 1 O 4 on chair inversion. We postulate that this conformational change results from the torque generated by the glycosidic bonds when a force is applied to the pectin molecule. Hence, the glycosidic bonds act as mechanical levers, driving the conformational transitions of the pyranose ring. When the glycosidic bonds are equatorial (e), the torque is zero, causing no conformational change. However, when the glycosidic bond is axial (a), torque is generated, causing a rotation around C—C bonds and a conformational change. This hypothesis readily predicts the number of transitions observed in pyranose monomers with 1a-4a linkages (two), 1a-4e (one), and 1e-4e (none). Our results demonstrate single-molecule mechanochemistry with the capability of resolving complex conformational transitions.