Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Stent-Assisted Coiling of a Sidewall Aneurysm of the Distal Middle Cerebral Artery: 2-Dimensional Operative Video
Abstract Sidewall aneurysm treatment often requires complex management strategies. These can include advanced clipping techniques or stent-assisted coiling techniques. Endovascular coiling alone has been associated with high recurrence rates and is often not feasible. 1-4 Flow-diversion embolization has recently become a standard of care for many aneurysms, demonstrating high occlusion rates. 4,5 However, the third generation of coil-assist stents can be delivered with 0.0165” microcatheters, being an ideal adjunct to manage this group of aneurysms in more distal locations. In this video, a 16-yr-old teenager with Parry-Romberg syndrome and congenital adrenal hyperplasia had an incidental finding of a 6.5-mm sidewall aneurysm arising off the angular branch of the left middle cerebral artery, found during the work-up of complex partial seizures. The patient consented to the procedure. Due to his young age and aneurysm size, a decision was made to treat the aneurysm through an endovascular approach. Under general anesthesia, a transfemoral approach was carried out using a 6-French short sheath. A 6-French guiding catheter was left in the distal cervical left internal carotid artery; a 0.0165” microcatheter was used to first deploy a 3.0 × 15 mm Neuroform Atlas stent, completely covering the length of the aneurysm. Then, the stent was traversed with the microcatheter to coil the aneurysm. Follow-up cerebral angiogram confirmed complete occlusion of the aneurysm.
The Use of Antiplatelet Agents and Heparin in the 24-Hour Postintravenous Alteplase Window for Neurointervention
Abstract BACKGROUND Intravenous (IV) alteplase with mechanical thrombectomy has been found to be superior to alteplase alone in select patients with intracranial large vessel occlusion. Current guidelines discourage the use of antiplatelet agents or heparin for 24 h following alteplase. However, their use is often necessary in certain circumstances during thrombectomy procedures. OBJECTIVE To study the safety and outcomes in patients who received blood thinning medications for thrombectomy after IV Tissue-Type plasminogen activator (tPA). METHODS This is a multicenter retrospective review of the use of antiplatelet agents and/or heparin in patients within 24 h following tPA administration. Patient demographics, comorbidities, bleeding complications, and discharge outcomes were collected. RESULTS A series of 88 patients at 9 centers received antiplatelet medications and/or heparin anticoagulation following IV alteplase for revascularization procedures requiring stenting. The mean National Institutes of Health Stroke Scale (NIHSS) on admission was 14.6. Reasons for use of a stent included internal carotid artery occlusion in 74% of patients. Thrombolysis in cerebral infarction (TICI) 2b-3 revascularization was accomplished in 90% of patients. The rate of symptomatic intracranial hemorrhage (sICH) was 8%; this was not significantly different than the sICH rate for a matched group of patients not receiving antiplatelets or heparin during the same time frame. Functional independence at 90 d (modified Rankin Scale 0-2) was seen in 57.8% of patients. All-cause mortality was 12%. CONCLUSION The use of antiplatelet agents and heparin for stroke interventions following IV alteplase appears to be safe without significant increased risk of hemorrhagic complications in this group of patients when compared to control data and randomized controlled trials.
Letter: An International Investigation Into the COVID-19 Pandemic and Workforce Depletion in Highly Specialized Neurointerventional Units – Insights From Stroke Thrombectomy and Aneurysm Registry and Endovascular Neurosurgery Research Group
Background The COVID-19 pandemic has disrupted established care paths worldwide. Patient awareness of the pandemic and executive limitations imposed on public life have changed the perception of when to seek care for acute conditions in some cases. We sought to study whether there is a delay in presentation for acute ischemic stroke patients in the first month of the pandemic in the US. Methods The interval between last-known-well (LKW) time and presentation of 710 consecutive patients presenting with acute ischemic strokes to 12 stroke centers across the US were extracted from a prospectively maintained quality database. We analyzed the timing and severity of the presentation in the baseline period from February to March 2019 and compared results with the timeframe of February and March 2020. Results There were 320 patients in the 2-month baseline period in 2019, there was a marked decrease in patients from February to March of 2020 (227 patients in February, and 163 patients in March). There was no difference in the severity of the presentation between groups and no difference in age between the baseline and the COVID period. The mean interval from LKW to the presentation was significantly longer in the COVID period (603±1035 min) compared with the baseline period (442±435 min, P<0.02). Conclusion We present data supporting an association between public awareness and limitations imposed on public life during the COVID-19 pandemic in the US and a delay in presentation for acute ischemic stroke patients to a stroke center.
The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil
Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract
The fate of cranial neuropathy after flow diversion for carotid aneurysms
Journal of Neurosurgery | October 16, 2015 | Volume: 124 | Issue: 4 | Pages: 1107-1113
OBJECT The authors sought to determine whether flow diversion with the Pipeline Embolization Device (PED) can approximate microsurgical decompression in restoring function after cranial neuropathy following carotid artery aneurysms. METHODS This multiinstitutional retrospective study involved 45 patients treated with PED across the United States. All patients included presented between November 2009 and October 2013 with cranial neuropathy (cranial nerves [CNs] II, III, IV, and VI) due to intracranial aneurysm. Outcome analysis included clinical and procedural variables at the time of treatment as well as at the latest clinical and radiographic follow-up. RESULTS Twenty-six aneurysms (57.8%) were located in the cavernous segment, while 6 (13.3%) were in the clinoid segment, and 13 (28.9%) were in the ophthalmic segment of the internal carotid artery. The average aneurysm size was 18.6 mm (range 4–35 mm), and the average number of flow diverters placed per patient was 1.2. Thirty-eight patients had available information regarding duration of cranial neuropathy prior to treatment. Eleven patients (28.9%) were treated within 1 month of symptom onset, while 27 (71.1%) were treated after 1 month of symptoms. The overall rate of cranial neuropathy improvement for all patients was 66.7%. The CN deficits resolved in 19 patients (42.2%), improved in 11 (24.4%), were unchanged in 14 (31.1%), and worsened in 1 (2.2%). Overtime, the rate of cranial neuropathy improvement was 33.3% (15/45), 68.8% (22/32), and 81.0% (17/21) at less than 6, 6, and 12 months, respectively. At last follow-up, 60% of patients in the isolated CN II group had improvement, while in the CN III, IV, or VI group, 85.7% had improved. Moreover, 100% (11/11) of patients experienced improvement if they were treated within 1 month of symptom onset, whereas 44.4% (12/27) experienced improvement if they treated after 1 month of symptom onset; 70.4% (19/27) of those with partial deficits improved compared with 30% (3/10) of those with complete deficits. CONCLUSIONS Cranial neuropathy caused by cerebral aneurysm responds similarly when the aneurysm is treated with the PED compared with open surgery and coil embolization. Lower morbidity and higher occlusion rates obtained with the PED may suggest it as treatment of choice for some of these lesions. Time to treatment is an important consideration regardless of treatment modality.
Endovascular treatment of acute ischemic stroke: the end or just the beginning?
Various endovascular intraarterial approaches are available for treating patients with acute ischemic stroke who present with severe neurological deficits. Three recent randomized trials—Interventional Management of Stroke (IMS) III, Mechanical Retrieval and Recanalization of Stroke Clots Using Embolectomy (MR RESCUE), and Synthesis Expansion: A Randomized Controlled Trial on Intra-Arterial Versus Intravenous Thrombolysis in Acute Ischemic Stroke (SYNTHESIS Expansion)—evaluated the efficacy of endovascular treatment of acute ischemic stroke and, after failing to demonstrate any significant clinical benefit of endovascular therapies, raised concerns and questions in the medical community regarding the future of endovascular treatment for acute ischemic stroke. In this paper, the authors review the evolution of endovascular treatment strategies for the treatment of acute stroke and provide their interpretation of findings and potential limitations of the three recently published randomized trials. The authors discuss the advantage of stent-retriever technology over earlier endovascular approaches and review the current status and future directions of endovascular acute stroke studies based on lessons learned from previous trials.