Back to Authors

Shen, Win-Kuang

A5110148961 | I4210125099

Mayo Clinic

Mayo Clinic in Arizona

Citations 21

Cardioneuroablation for the treatment of reflex syncope and functional bradyarrhythmias: A Scientific Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS) and th

Europace | July 30, 2024 | Volume: 26 | Issue: 8 | Pages: No page available

10.1093/europace/euae206 | PMID 39082698

Abstract Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.
The impact of pulsed electromagnetic field therapy on blood pressure and circulating nitric oxide levels: a double blind, randomized study in subjects with metabolic syndrome

Blood Pressure | August 9, 2019 | Volume: 29 | Issue: 1 | Pages: 47-54

10.1080/08037051.2019.1649591 | PMID 31394939

A Systematic Review of Noninvasive Electrocardiogram Monitoring Devices for the Evaluation of Suspected Cardiovascular Syncope

Journal of Medical Devices | February 8, 2019 | Volume: 13 | Issue: 2 | Pages: No page available

10.1115/1.4042795

The aims of this study were (1) to identify research publications studying noninvasive electrocardiogram (ECG) monitoring devices, (2) to define and categorize current technology in noninvasive ECG recording, and (3) to discuss desirable noninvasive recording features for personalized syncope evaluation to guide technological advancement and future studies. We performed a systematic review of the literature that assessed noninvasive ECG-monitoring devices, regardless of the reason for monitoring. We performed an Internet search and corresponded with syncope experts and companies to help identify further eligible products. We extracted information about included studies and device features. We found 173 relevant papers. The main reasons for ECG monitoring were atrial fibrillation (n = 45), coronary artery disease (n = 10), syncope (n = 8), palpitations (n = 8), other cardiac diseases (n = 67), and technological aspects of monitoring (n = 35). We identified 198 devices: 5 hospital telemetry devices, 12 patches, 46 event recorders, 70 Holter monitors, 23 external loop recorders, 20 mobile cardiac outpatient telemetries, and 22 multifunctional devices. The features of each device were very heterogeneous. There are a large number of ECG-monitoring devices with different features available in the market. Our findings may help clinicians select the appropriate device for their patients. Since there are only a few published articles analyzing their usefulness in syncope patients, further research might improve their use in this clinical setting.
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures

Circulation | October 18, 2017 | Volume: 137 | Issue: 1 | Pages: 24-33

10.1161/circulationaha.117.030523 | PMID 29046320

Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Response by Mulpuru and Shen to Letter Regarding Article, “Selective Modulation of the Cardiac Autonomic Nervous System: A New Strategy for Treatment of Cardioinhibitory Syncope”

Circulation: Arrhythmia and Electrophysiology | July 14, 2017 | Volume: 10 | Issue: 7 | Pages: No page available

10.1161/circep.117.005523 | PMID 28705879

Assessment and Treatment of Syncope

JAMA Cardiology | June 14, 2017 | Volume: 2 | Issue: 8 | Pages: 920

10.1001/jamacardio.2017.1784 | PMID 28614562

Regulation of vascular large-conductance calcium-activated potassium channels by Nrf2 signalling

Diabetes and Vascular Disease Research | April 21, 2017 | Volume: 14 | Issue: 4 | Pages: 353-362

10.1177/1479164117703903 | PMID 28429615

BK channels are major ionic determinants of vasodilation. BK channel function is impaired in diabetic vessels due to accelerated proteolysis of its beta-1 (BK-β1) subunits in response to increased oxidative stress. The nuclear factor E2-related factor-2 (Nrf2) signalling pathway has emerged as a master regulator of cellular redox status, and we hypothesized that it plays a central role in regulating BK channel function in diabetic vessels. We found that Nrf2 expression was markedly reduced in db/db diabetic mouse aortas, and this was associated with significant downregulation of BK-β1. In addition, the muscle ring finger protein 1 (MuRF1), a known E-3 ligase targeting BK-β1 ubiquitination and proteasomal degradation, was significantly augmented. These findings were reproduced by knockdown of Nrf2 by siRNA in cultured human coronary artery smooth muscle cells. In contrast, adenoviral transfer of Nrf2 gene in these cells downregulated MuRF1 and upregulated BK-β1 expression. Activation of Nrf2 by dimethyl fumarate preserved BK-β1 expression and protected BK channel and vascular function in db/db coronary arteries. These results indicate that expression of BK-β1 is closely regulated by Nrf2 and vascular BK channel function can be restored by Nrf2 activation. Nrf2 should be considered a novel therapeutic target in the treatment of diabetic vasculopathy.
Selective Modulation of the Cardiac Autonomic Nervous System

Circulation: Arrhythmia and Electrophysiology | February 15, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.117.004994 | PMID 28202632

Incidence of Idiopathic Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 | PMID 28183845

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Atrial Fibrillation in the Elderly: A Review

Future Cardiology | December 12, 2014 | Volume: 10 | Issue: 6 | Pages: 745-758

10.2217/fca.14.32 | PMID 25495816