Citations 164

Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | June 5, 2008 | Volume: 1 | Issue: 1 | Pages: 30-38

10.1161/circep.107.750315 | PMID 19808391

Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Catheter Ablation for Atrial Fibrillation in Patients With Obesity

Circulation | May 13, 2008 | Volume: 117 | Issue: 20 | Pages: 2583-2590

10.1161/circulationaha.107.716712 | PMID 18474813

Background— Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results— Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped by body mass index (lean, <25 kg/m 2 ; overweight, 25 to 29.9 kg/m 2 ; obese, ≥30 kg/m 2 ). Outcome and quality of life were measured with a general health survey (Medical Outcomes Study 36-item Short-Form General Health Survey [SF-36]); patients were assessed before ablation and at 3 and 12 months after the procedure. Two hundred twenty-eight study patients (44%) were overweight, and 201 (38%) were obese. Twelve months after curative ablation, 72% of patients were free of atrial fibrillation without the use of antiarrhythmic agents; 84% were arrhythmia free when those receiving medication were included. Atrial fibrillation was eliminated in 75%, 72%, and 70% of the lean, overweight, and obese patients, respectively, at 12 months ( P =0.41, trend test). SF-36 scores were lower for patients with higher body mass index ( P <0.05) at baseline. SF-36 scores improved in every functional domain for all body mass index groups after ablation. The mean SF-36 total physical score increased from 59±20 at baseline to 77±19 in 12 months ( P <0.001). The total mental health score improved from 66±18 to 79±16 in 12 months ( P <0.001). Conclusions— Catheter ablation of atrial fibrillation was effective in obese patients. Coexistence of atrial fibrillation and obesity indicated lower SF-36 scores, but the improvement in quality of life was consistent across all body mass index categories.
Comparison of Echocardiographic Dyssynchrony Assessment by Tissue Velocity and Strain Imaging in Subjects With or Without Systolic Dysfunction and With or Without Left Bundle-Branch Block

Circulation | May 12, 2008 | Volume: 117 | Issue: 20 | Pages: 2617-2625

10.1161/circulationaha.107.733675 | PMID 18474810

Background— Several echocardiographic dyssynchrony indexes have been proposed to identify responders to cardiac resynchronization therapy using tissue velocity and strain. The present study aimed to compare tissue velocity–derived and strain-derived dyssynchrony indexes in patients with or without systolic dysfunction and left bundle-branch block. Methods and Results— Tissue Doppler imaging was performed in 120 subjects divided into 4 groups: group 1 (n=40), normal subjects; group 2 (n=20), normal left ventricular ejection fraction and left bundle-branch block; group 3 (n=20), left ventricular ejection fraction <35% and normal conduction; and group 4 (n=40), left ventricular ejection fraction <35% and left bundle-branch block. Dyssynchrony indexes based on time to peak tissue velocity (septal-lateral delay, anteroseptal-posterior delay, and SD in time to peak systolic velocity in the 12 left ventricular segments) and strain (SD of time to peak strain in 12 segments) were measured. The SD in time to peak systolic velocity in the 12 left ventricular segments was greater in group 4 (54 ms; 25th and 75th percentiles, 46 to 64 ms) than group 1 (44 ms; 25th and 75th percentiles, 28 to 53 ms; P =0.006), but there was a considerable overlap of all tissue velocity–derived indexes among 4 groups, with 40% to 68% of group 1 having values proposed for predicting the responders of cardiac resynchronization therapy. The SD of time to peak strain in 12 segments distinguished these groups with much less overlap ( P <0.01 for all pairwise comparisons). Conclusions— A substantial proportion of normal subjects have tissue velocity–derived dyssynchrony indexes higher than the cutoff value proposed for predicting beneficial effect of cardiac resynchronization therapy. Strain-derived timing index appears to be more specific for dyssynchrony in patients with systolic dysfunction and left bundle-branch block. Identifying an optimal tissue velocity– or strain-derived dyssynchrony index requires a large prospective clinical trial.
Atrial Fibrillation and Ventricular Dysfunction

Circulation | June 14, 2004 | Volume: 109 | Issue: 23 | Pages: 2839-2843

10.1161/01.cir.0000132470.78896.a8 | PMID 15197156