Citations 164

Cardiac resynchronization therapy improves myocardial conduction

Pacing and Clinical Electrophysiology | December 13, 2018 | Volume: 42 | Issue: 2 | Pages: 238-246

10.1111/pace.13581 | PMID 30548634

AbstractBackgroundCardiac resynchronization therapy (CRT) reverses left ventricular remodeling and improves left ventricular systolic function. However, little is known about whether CRT improves ventricular conduction.ObjectiveTo determine the relationship between CRT response and QRS narrowing.MethodsThe study included consecutive patients who underwent CRT with defibrillator (CRT‐D) implantation between January 2002 and December 2012 and had subsequent generator replacement (GR). At the time of GR, super‐responder was defined as those who had left ventricular ejection fraction (LVEF) of 50% or more; patients who had an LVEF of 36–49% with an increase of more than 5% were considered responders, and the others were nonresponders. All patients were assessed 6 months after CRT‐D implantation and at the time of GR.ResultsOf 114 study patients, 58 (50.9%) were nonresponders, 29 (25.4%) responders, and 27 (23.7%) super‐responders. QRS narrowing at 6 months was significant in super‐responders (175.4 ± 21.4 to 159.7 ± 20.7 ms, P = 0.001) and responders (169.0 ± 21.3 to 157.7 ± 17.6 ms, P = 0.008). At time of GR, only super‐responders had further QRS narrowing (159.7 ± 20.7 to 146.3 ± 19.2 ms, P < 0.001). QRS duration change after 6 months was independently associated with super‐response (hazard ratio: 1.20 for every 5 ms QRS duration narrowing; 95% confidence interval, 1.06–1.38; P = 0.005), and QRS narrowing of 10 ms or more was associated with lower risk of all‐cause mortality after GR.ConclusionContinuous QRS narrowing after CRT, as an electrical marker, is associated with a super‐response to CRT. Further QRS narrowing 6 months after CRT implantation was associated with lower risk of mortality after GR.
Response letter‐to‐the editor entitled “Transvenous lead extraction, only once or repeatable?”

Pacing and Clinical Electrophysiology | December 5, 2018 | Volume: 42 | Issue: 2 | Pages: 297-297

10.1111/pace.13561 | PMID 30516285

Super-response to cardiac resynchronization therapy reduces appropriate implantable cardioverter-defibrillator therapy: comment—Authors’ reply

EP Europace | November 2, 2018 | Volume: 21 | Issue: 1 | Pages: 179-179

10.1093/europace/euy244 | PMID 30428067

Diagnostic and therapeutic value of implantable loop recorder: A tertiary care center experience

Pacing and Clinical Electrophysiology | October 25, 2018 | Volume: 42 | Issue: 1 | Pages: 38-45

10.1111/pace.13533 | PMID 30357866

AbstractBackgroundImplantable loop recorders (ILRs) are effective in achieving symptom‐rhythm correlation. However, diagnostic yield in routine clinical practice is not well established.MethodsPatients undergoing ILR implantation between April 2010 and May 2015 were included. All devices were enrolled in remote monitoring with automatic arrhythmia detection and P sense algorithms switched “ON.” Symptom‐rhythm correlation was assessed and changes in management were recorded.ResultsA total of 312 patients (57% male, age 53 ± 22 years; median CHADS2VaSc score = 1) were included in this study. ILRs were implanted for evaluation of syncope in 206 (66.0%), presyncope in 23 (7.4%), unexplained palpitations in 51 (16.3%), and cryptogenic stroke in 27 (8.7%) patients. ILR monitoring yielded a diagnosis that changed management strategy in 146 (46.8%) patients over a median of 12 (1‐42) months. Out of 163 (52.2%) patients with symptoms during the monitoring period, 100 (61.3%) had an arrhythmia. ILR was useful in ruling out an arrhythmic cause for symptoms in 63 (38.7%) patients. ILR results led to pacemaker implantation in 23 patients (7.4% overall and 11.2% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, 11 of whom were initiated on oral anticoagulants. ILR results led to pacemaker implantation in 31 patients (9.9% overall and 19.0% of those with syncope) after median follow‐up of 3 months. A new diagnosis of atrial fibrillation was made in 38 (12.2%) patients, nine of whom were initiated on oral anticoagulants. Overall, ILR led to a change in management in 47% patients with a number needed to implant of 2.1 to change management.ConclusionILR monitoring is effective in achieving symptom‐rhythm correlation and results in changes in management in nearly half of implanted patients. Additional studies are needed to evaluate cost efficacy of ILR and the optimal monitoring duration.
Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death

Circulation: Arrhythmia and Electrophysiology | September 17, 2018 | Volume: 9 | Issue: 3 | Pages: No page available

10.1161/circep.115.003283 | PMID 26921377

Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement

Circulation: Arrhythmia and Electrophysiology | September 14, 2018 | Volume: 11 | Issue: 8 | Pages: No page available

10.1161/circep.117.006155 | PMID 30354311

Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
Outcomes of repeated transvenous lead extraction

Pacing and Clinical Electrophysiology | July 30, 2018 | Volume: 41 | Issue: 10 | Pages: 1321-1328

10.1111/pace.13464 | PMID 30058073

AbstractIntroductionThe outcomes of repeated cardiovascular implantable electronic device (CIED) lead extraction have not been well studied. We sought to determine the indications, outcomes, and safety of repeated lead extraction procedures.MethodsThis retrospective study was conducted using data from two medical centers, including 38 patients who had undergone two or more lead extraction procedures compared to 439 patients who had a single procedure. The electronic medical records and procedural databases were reviewed to determine the indications, procedural characteristics, and outcomes. The outcomes of the first procedure were compared to the outcomes of subsequent procedures.ResultsThe 5‐year cumulative probability of a repeated extraction procedure was 11% (95% confidence interval, 7%–15%). In 439 patients who underwent single lead extractions, 72% had device and lead related infections as the procedure indication compared to 39% for 38 patients who underwent repeated extraction (P < 0.001). The mean duration from device reimplant to repeated extraction procedures was 63 ± 48 months. Ninety‐eight percent of the leads were removed completely in repeated procedures, similar to the 95% success rate of the first procedure (P = 0.51). There was no significant difference in major complication rate in the first or repeated extractions (2.6% vs 5.2%, P = 0.79).ConclusionsRepeated transvenous lead extraction is not uncommon. It had a high success rate comparable to that of the initial procedure and was not associated with an increased incidence of adverse events.
Frequency of in‐hospital adverse outcomes and cost utilization associated with cardiac resynchronization therapy defibrillator implantation in the United States

Journal of Cardiovascular Electrophysiology | July 17, 2018 | Volume: 29 | Issue: 10 | Pages: 1425-1435

10.1111/jce.13701 | PMID 30016005

AbstractBackground: The utilization of cardiac resynchronization therapy defibrillator (CRT‐D) has increased significantly, since its initial approval for use in selected patients with heart failure. Limited data exist as for current trends in implant‐related in‐hospital complications and cost utilization. The aim of our study was to examine in‐hospital complication rates associated with CRT‐D and their trends over the last decade.Methods and Results: Using the Nationwide Inpatient Sample, we estimated 378 248 CRT‐D procedures from 2003 to 2012. We investigated common complications, including mechanical, cardiovascular, pericardial complications (hemopericardium, cardiac tamponade, or pericardiocentesis), pneumothorax, stroke, vascular complications (consisting of hemorrhage/hematoma, incidents requiring surgical repair, and accidental arterial puncture), and in‐hospital deaths described with CRT‐D, defining them by the validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis code. Mechanical complications (5.9%) were the commonest, followed by cardiovascular (3.6%), respiratory failure (2.4%), and pneumothorax (1.5%). Age (≥65 years), female gender (OR, 95% CI; P value) (1.08, 1.03‐1.13; 0.001), and the Charlson score ≥3 (1.52, 1.45‐1.60; <0.001) were significantly associated with increased mortality/complications.Conclusions: The overall complication rate in patients undergoing CRT‐D has been increasing in the last decade. Age (≥65), female sex, and the Charlson score ≥3 were associated with higher complications. In patients who underwent CRT‐D implantation, postoperative complications were associated with significant increases in cost.
Fragmentation of QRS complex during ventricular pacing is associated with ventricular arrhythmic events in patients with left ventricular dysfunction

Journal of Cardiovascular Electrophysiology | June 2, 2018 | Volume: 29 | Issue: 9 | Pages: 1248-1256

10.1111/jce.13656 | PMID 29858880

AbstractBackgroundQRS fragmentation (fQRS) during baseline ventricular conduction, a myocardial fibrosis marker, is associated with increased risk of ventricular tachyarrhythmias but may not manifest unless ventricular activation change is provoked. We examined the association of fQRS during right ventricular (RV) pacing with death and ventricular tachyarrhythmia in patients with left ventricular (LV) dysfunction undergoing electrophysiology study (EPS).Methods and resultsStudy participants had LV dysfunction (ejection fraction < 50%) undergoing EPS from January 2002 to May 2014 at Mayo Clinic in Rochester, Minnesota. fQRS during RV stimulation involved >2 notches on R/S waves identified in ≥2 contiguous standard electrocardiographic leads representing anterior, inferior, or lateral ventricular segments. Primary outcomes were ventricular tachyarrhythmias that were symptomatic or required intervention and total and cardiac deaths. In all, 528 patients participated (mean age, 65 years; male sex, 80%). Of them, 312 (59%) had ischemic cardiomyopathy and mean (SD) left ventricular ejection fraction (LVEF) of 33.2% (9.5%); 457 (87%) had implantable cardiac devices (implanted defibrillator, n = 380). Mean (SD) follow‐up was 3.2 (3.0) years. fQRS during RV pacing was observed in 292 patients (60%) in any ventricular segment. Patients with fQRS during RV pacing had 2.5 higher rate of ventricular tachyarrhythmia events than patients with no fQRS (hazard ratio [95% CI], 2.45 [1.5–4.2]; P < 0.01), after correcting for baseline ventricular conduction defect and QRS duration, LVEF, inducible sustained ventricular tachycardia, diabetes mellitus, chronic kidney disease, and ischemic cardiomyopathy.ConclusionsRV stimulation can unmask fQRS, and it is associated with increased risk of ventricular tachyarrhythmia in LV dysfunction.
Outcomes of video‐assisted thoracoscopic surgery for transvenous lead extraction

Journal of Cardiovascular Electrophysiology | June 2, 2018 | Volume: 29 | Issue: 7 | Pages: 1032-1037

10.1111/jce.13643 | PMID 29858883

AbstractIntroductionTo evaluate the outcomes of video‐assisted thoracoscopic surgery (VATS) during transvenous lead extractions (TLEs).Methods and resultsNinety‐one high‐risk patients who underwent TLE in the operating room from January 1, 2015, to March 31, 2017, were included in the study. Of these, 9 patients underwent VATS during TLE. Their clinical characteristics, indications for lead extraction, and complications associated with TLE in the 9 patients who had VATS were compared with those for the 82 patients who did not have VATS. The mean (SD) age of the study patients was 61 (17) years (64.8% were male). The lead dwell time, number of leads extracted, and clinical comorbidities were similar between the 2 groups. Superior vena cava (SVC) tear occurred in 2 of the 9 patients in VATS group and in 1 of the 82 in the non‐VATS group (22.2% vs. 1.2%, P = 0.03). Of the 2 patients in the VATS group who had SVC tears, in 1 the tear was visualized immediately and there was no hemodynamic compromise. In the other patient, the SVC tear was within the pericardium; the blood pressure recovered quickly after sternotomy and repair. Both patients had complete lead extraction and survived hospitalization. The patient in the non‐VATS group who had an SVC tear had a successful repair but died of postoperative complications.ConclusionsUtilization of VATS to facilitate TLE is beneficial for early recognition of SVC tear and timely surgical repair in select high‐risk patients.