Stellate ganglion block and cardiac sympathetic denervation in patients with inappropriate sinus tachycardia

Journal of Cardiovascular Electrophysiology | October 18, 2019 | Volume: 30 | Issue: 12 | Pages: 2920-2928

10.1111/jce.14233 | PMID 31625219

AbstractBackgroundInappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy.ObjectiveTo study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST.MethodsTwelve consecutive patients who had drug‐refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD.ResultsThe mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement.ConclusionSG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.
Contemporary Management of Antiplatelet and Anticoagulation for Cardiac Implantable Device Procedures

Circulation: Arrhythmia and Electrophysiology | October 15, 2019 | Volume: 12 | Issue: 10 | Pages: No page available

10.1161/circep.119.007863 | PMID 31610719

Effective Use of Percutaneous Stellate Ganglion Blockade in Patients With Electrical Storm

Circulation: Arrhythmia and Electrophysiology | September 13, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.118.007118 | PMID 31514529

Background: Percutaneous stellate ganglion blockade (SGB) has been used for drug-refractory electrical storm due to ventricular arrhythmia (VA); however, the effects and long-term outcomes have not been well studied. Methods: This study included 30 consecutive patients who had drug-refractory electrical storm and underwent percutaneous SGB between October 1, 2013, and March 31, 2018. Bupivacaine, alone or combined with lidocaine, was injected into the neck with good local anesthetic spread in the vicinity of the left stellate ganglion (n=15) or both stellate ganglia (n=15). Data were collected for patient clinical characteristics, immediate and long-term outcomes, and procedure-related complications. Results: Clinical characteristics included age, 58±14 years; men, 73.3%; and left ventricular ejection fraction, 34±16%. At 24 hours, 60% of patients were free of VA. Patients whose VA was controlled had a lower hospital mortality rate than patients whose VA continued (5.6% versus 50.0%; P =0.009). Implantable cardioverter-defibrillator interrogation showed a significant 92% reduction in VA episodes from 26±41 to 2±4 in the 72 hours after SGB ( P <0.001). Patients who died during the same hospitalization (n=7) were more likely to have ischemic cardiomyopathy (100% versus 43.5%; P =0.03) and recurrent VA within 24 hours (85.7% versus 26.1%; P =0.009). There were no procedure-related major complications. Conclusions: SGB effectively attenuated electrical storm in more than half of patients without procedure-related complications. Percutaneous SGB may be considered for stabilizing ventricular rhythm in patients for whom other therapies have failed.
Incidence and Natural History of Left Bundle Branch Block Induced Cardiomyopathy

Circulation: Arrhythmia and Electrophysiology | September 12, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.119.007393 | PMID 31510788

Association between the Charlson comorbidity index and outcomes after implantable cardioverter defibrillator generator replacement

Pacing and Clinical Electrophysiology | July 29, 2019 | Volume: 42 | Issue: 9 | Pages: 1236-1242

10.1111/pace.13762 | PMID 31355952

AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.
Incidence and outcomes of systemic infections in patients with leadless pacemakers: Data from the Micra IDE study

Pacing and Clinical Electrophysiology | June 24, 2019 | Volume: 42 | Issue: 8 | Pages: 1105-1110

10.1111/pace.13752 | PMID 31232461

AbstractBackgroundThe Micra clinical trials have enrolled more than 2500 patients without any reported device‐related infections that required removal during follow‐up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation.ObjectiveTo analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow‐up in patients with history of Micra leadless pacemaker implantation.MethodsSIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow‐up.ResultsAmong patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram‐positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram‐positive bacteria), and gram‐negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow‐upConclusionIn this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.
Electrophysiologic effects and outcomes of sympatholysis in patients with recurrent ventricular arrhythmia and structural heart disease

Journal of Cardiovascular Electrophysiology | June 14, 2019 | Volume: 30 | Issue: 9 | Pages: 1499-1507

10.1111/jce.14030 | PMID 31199536

AbstractIntroductionAutonomic modulation has been used as a therapy to control recurrent ventricular arrhythmia (VA). This study was to explore stellate ganglion block (SGB) effect on cardiac electrophysiologic properties and evaluate the long‐term outcome of cardiac sympathetic denervation (CSD) for patients with recurrent VA and structural heart disease (SHD).Materials and MethodsPatients who had recurrent VA due to SHD were enrolled prospectively. Electrophysiologic study and ventricular tachycardia (VT) induction were performed before and after left and right SGB. VA burden and long‐term outcomes were assessed for a separate patient group who underwent left or bilateral CSD for drug‐refractory VA due to SHD.ResultsElectrophysiologic study of nine patients showed that baseline mean (SD) corrected sinus node recovery time (cSNRT) increased from 320.4 (73.3) ms to 402.9 (114.2) ms after left and 482.4 (95.7) ms after bilateral SGB (P = .03). SGB did not significantly change P‐R, QRS, and Q‐T intervals and ventricular effective refractory period, nor did the inducibility of VA. Nineteen patients underwent left (n = 14) or bilateral (n = 5) CSD. CSD reduced VA burden and appropriate ICD therapies from a median (interquartile range) of 2.5 (0.4‐11.6) episodes weekly to 0.1 (0.0‐2.4) episodes weekly at 6‐month follow‐up (P = .002). Three‐year freedom from orthotopic heart transplant (OHT) and death was 52.6%. New York Heart Association functional class III/IV and VT rate less than 160 beats per minute were predictors of recurrent VA, OHT, and death.ConclusionSGB increased cSNRT without changing heart rate. CSD was more beneficial for patients with mild‐to‐moderate heart failure and faster VA.
Efficacy of Pharmacologic and Cardiac Implantable Electronic Device Therapies in Patients With Heart Failure and Reduced Ejection Fraction

Circulation: Arrhythmia and Electrophysiology | June 4, 2019 | Volume: 12 | Issue: 6 | Pages: No page available

10.1161/circep.118.006951 | PMID 31159582

Background: The treatment of heart failure with reduced ejection fraction has been the subject of numerous randomized controlled trials involving medications and cardiac implantable electronic device therapies. As newer effective pharmacological therapies suggest significant reductions in all-cause mortality, the role of additional device therapy in heart failure with reduced ejection fraction deserves further scrutiny. Methods: A systematic review and network meta-analysis on the effect of medication and device therapies in heart failure with reduced ejection fraction on all-cause mortality was performed. Randomized controlled trials published between January 1980 and July 2017 were identified using Medline, EMBASE, and Cochrane Controlled Register of Trials databases. Pcnetmeta package in R was used to calculate treatment arm–based estimated rates, rate ratios, and probability ranks with 95% credible intervals. Results: Combination therapy of ACE (angiotensin-converting enzyme) inhibitors or ARBs (angiotensin receptor blockers) with β-blockers (BBs) alone or in addition to implantable cardiac defibrillators or cardiac resynchronization therapy with defibrillators demonstrated a significant reduction of all-cause mortality when compared with placebo. By probability rank, implantable cardiac defibrillator+ACE inhibitor or ARB+BB+mineralocorticoid receptor antagonist, implantable cardiac defibrillator+ACE inhibitor or ARB+BB, and angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist combination therapies have the highest probability of being ranked the best treatment. There was no significant difference in the rate of mortality when comparing angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist to implantable cardiac defibrillator+optimal pharmacological combination therapy. Conclusions: BB and renin-angiotensin system blockers alone or in combination with defibrillator device therapy have robust evidence for a reduction in mortality compared with placebo. The comparative efficacy of pharmacological therapy with angiotensin receptor-neprilysin inhibitors and device therapy deserves further investigation.
Real‐world experience with leadless cardiac pacing

Pacing and Clinical Electrophysiology | January 11, 2019 | Volume: 42 | Issue: 3 | Pages: 366-373

10.1111/pace.13601 | PMID 30632622

AbstractBackgroundLeadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.MethodsPatients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).ResultsNinety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).ConclusionThere are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
Lead extraction for reduction of chronic pain related to cardiovascular implantable electronic device

EP Europace | December 20, 2018 | Volume: 21 | Issue: 5 | Pages: 781-786

10.1093/europace/euy320 | PMID 30698694