Citations 164

Clinical implications of elective replacement indicator setting changes in patients with dual‐chamber pacemaker devices

Journal of Cardiovascular Electrophysiology | July 16, 2020 | Volume: 31 | Issue: 10 | Pages: 2704-2710

10.1111/jce.14677 | PMID 32671902

AbstractObjectiveThis study sought to determine if single‐chamber operation and/or loss of rate response (RR) during elective replacement indicator (ERI) in patients with dual‐chamber pacemakers lead to increased symptom burden, healthcare utilization, and atrial fibrillation (AF).BackgroundDual‐chamber pacemakers often change from dual‐ to single‐chamber pacing mode and/or lose RR functionality at ERI to preserve battery. Single‐chamber pacing increases the incidence of heart failure, AF, and pacemaker syndrome suggesting these changes may be deleterious.MethodsA retrospective analysis of 700 patients was completed. Three comparisons were analyzed: Comparison 1: mode change and RR loss versus no change; Comparison 2: RR loss only versus no change; Comparison 3: mode change only versus no change (in patients with no RR programmed at baseline).ResultsIn Comparison 1, 121 (46%) patients with setting changes experienced symptoms (most often dyspnea and fatigue/exercise intolerance) versus 3 (4%) without setting changes (p < .0001). Similar results were noted in Comparisons 2 and 3 (p = .0016 and p = .0001, respectively). In Comparison 1, patients with setting change sought provider contact more than patients without setting changes (p = .0001). A significant difference was not noted in Comparison 2 or 3. Overall 14 (2%) patients were hospitalized, all of whom had setting changes.ConclusionsSetting changes at ERI including a change from dual‐ to single‐chamber pacing and/or loss of RR results in a significantly increased symptom burden and increased healthcare utilization.
Management of ventricular electrical storm: a contemporary appraisal

EP Europace | July 15, 2020 | Volume: 22 | Issue: 12 | Pages: 1768-1780

10.1093/europace/euaa232 | PMID 32984880

Abstract Ventricular electrical storm (VES) is a clinical scenario characterized by the clustering of multiple episodes of sustained ventricular arrhythmias (VA) over a short duration. Patients with VES are prone to psychological disorders, heart failure decompensation, and increased mortality. Studies have shown that 10–28% of the patients with secondary prevention ICDs can sustain VES. The triad of a susceptible electrophysiologic substrate, triggers, and autonomic dysregulation govern the pathogenesis of VES. The rate of VA, underlying ventricular function, and the presence of implantable cardioverter-defibrillator (ICD) determine the clinical presentation. A multi-faceted approach is often required for management consisting of acute hemodynamic stabilization, ICD reprogramming when appropriate, antiarrhythmic drug therapy, and sedation. Some patients may be eligible for catheter ablation, and autonomic modulation with thoracic epidural anesthesia, stellate ganglion block, or cardiac sympathetic denervation. Hemodynamically unstable patients may benefit from the use of left ventricular assist devices, and extracorporeal membrane oxygenation. Special scenarios such as idiopathic ventricular fibrillation, Brugada syndrome, Long and short QT syndrome, early repolarization syndrome, catecholaminergic polymorphic ventricular tachycardia, arrhythmogenic right ventricular cardiomyopathy, and cardiac sarcoidosis have been described as well. VES is a cardiac emergency that requires swift intervention. It is associated with poor short and long-term outcomes. A structured team-based management approach is paramount for the safe and effective treatment of this sick cohort.
Fibroplasty (venoplasty) to facilitate transvenous lead placement: A single‐center experience

Journal of Cardiovascular Electrophysiology | July 8, 2020 | Volume: 31 | Issue: 9 | Pages: 2425-2430

10.1111/jce.14655 | PMID 32638422

AbstractIntroductionVenous stenosis is a well‐recognized complication of transvenous leads (TVLs) that is encountered during lead revisions or device upgrades. We here report the outcomes of TVL placement facilitated by fibroplasty or tunneling (TUN) procedure.MethodsWe conducted a single‐center retrospective cohort study of all patients undergoing TVL implantation requiring fibroplasty or TUN from 2005 to 2017. Medical records and procedure reports were reviewed for relevant data. Outcomes for fibroplasty and TUN to facilitate TVL placement were compared.ResultsSixty patients had fibroplasty and thirty‐five patients had a TUN procedure. There was no difference in procedure success rates between the two groups (97% fibroplasty vs. 100% TUN; p = .98). The fluoroscopy time was longer (fibroplasty = 39.7 ± 21.5 min vs. TUN = 29.2 ± 21.3 min; p = .01) and the total procedural time was shorter in the fibroplasty group (fibroplasty = 247 ± 77.8 min vs. TUN = 287 ± 77.1 min; p = .01). TUN was associated with a significantly higher incidence of acute complications (fibroplasty = 0 vs. TUN = 8; p = .002) most requiring invasive intervention and/or transfusion with blood products. Long‐term complications requiring additional device‐related procedures were comparable between the two groups (fibroplasty = 6 vs. TUN = 6; logrank p = .21).ConclusionsFor patients with venous stenosis requiring additional TVL, balloon fibroplasty is associated with similar rates of success and a significantly decreased incidence of acute complications when compared with subcutaneous TUN.
Outcomes of incident atrial fibrillation in heart failure with preserved or reduced ejection fraction: A community‐based study

Journal of Cardiovascular Electrophysiology | June 25, 2020 | Volume: 31 | Issue: 9 | Pages: 2275-2283

10.1111/jce.14632 | PMID 32584498

AbstractIntroductionThe best management strategy for patients with atrial fibrillation (AF) with heart failure (HF) and preserved left ventricular ejection fraction (LVEF) is unknown.Methods and ResultsThis cohort study was conducted in Olmsted County, Minnesota, with resources of the Rochester Epidemiology Project. Patients with incident AF occurring between 2000 and 2014 with a prior or concurrent HF were included. Patients with LVEF ≥ 50% were designated as HF and preserved ejection fraction (HFpEF) and those with LVEF < 50% were designated as HF and reduced ejection fraction (HFrEF). Rhythm control in the first year after AF diagnosis was defined as prescriptions for an antiarrhythmic drug, catheter ablation, or maze procedure. The primary endpoint was all‐cause mortality. The secondary endpoints were cardiovascular death, cardiovascular hospitalization, and stroke or transient ischemic attack. Of 859 patients (age, 77.2 ± 12.1 years; 49.2%, female), 447 had HFpEF‐AF, and 412 had HFrEF‐AF. There was no difference in all‐cause mortality (10‐year mortality, 83% vs 79%; p = .54) or secondary endpoints between the HFpEF‐AF and HFrEF‐AF, respectively. Compared with the rate control strategy, rhythm control in HFpEF‐AF patients (n = 40, 15.9%) offered no survival benefits (adjusted HR, 0.70; 95% CI, 0.42–1.16; p = .16), whereas rhythm control in HFrEF‐AF patients (n = 52, 22.5%) decrease cardiovascular mortality (HR, 0.38; 95% CI, 0.17–0.86; p = .02).ConclusionsPatients with HFpEF‐AF and HFrEF‐AF had similar poor prognoses. Rhythm control strategy was seldom adopted in community care in patients with HF and AF. A rhythm control strategy may provide survival benefit for patients with HFrEF‐AF and the benefit of rhythm control in patients with HFpEF‐AF warrants further study.
Outcomes of Cardiac Resynchronization Therapy in Patients with Hypothyroidism and Heart Failure

No container title available | April 21, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-23073/v1

Abstract Background Hypothyroidism is known to be associated with adverse clinical outcomes in heart failure. The association between hypothyroidism and cardiac resynchronization therapy outcomes in patients with severe heart failure is not clear. Methods The study included 1,316 patients who received cardiac resynchronization therapy between 2002 and 2015. Baseline demographics and cardiac resynchronization therapy outcomes, including left ventricular ejection fraction, New York Heart Association class, appropriate implantable cardioverter-defibrillator therapy, and all-cause mortality, were collected from the electronic health record. Results Of the study cohort, 349 patients (26.5%) were classified as the hypothyroidism group. The median duration of follow-up was 3.6 years (interquartile range, 1.7-6.2). Hypothyroidism was associated with a greater all-cause mortality than euthyroidism (hazard ratio, 1.19; 95% CI, 1.01-1.38; P=0.04). In this group, the risk of appropriate implantable cardioverter-defibrillator therapy significantly increased in association with increased baseline thyroid-stimulating hormone level (hazard ratio, 1.27 per 5 mIU/L increase, 95% CI, 1.00-1.53, P=0.04). Conclusions Cardiac resynchronization therapy improves cardiac function in hypothyroid patients. Hypothyroidism has adverse effects on cardiac resynchronization therapy outcomes with reduced survival and increased implantable cardioverter-defibrillator therapies for ventricular arrhythmic events.
Left Bundle Branch Block

Circulation: Arrhythmia and Electrophysiology | March 18, 2020 | Volume: 13 | Issue: 4 | Pages: No page available

10.1161/circep.119.008239 | PMID 32186936

Left bundle branch block may be due to conduction system degeneration or a reflection of myocardial pathology. Left bundle branch block may also develop following aortic valve disease or cardiac procedures. Patients with heart failure with reduced ejection fraction and left bundle branch block may respond positively to cardiac resynchronization therapy. Lead placement via the coronary sinus is the mainstay approach of cardiac resynchronization therapy. However, other options, including physiological pacing, are being explored. In this review, we summarize the salient pathophysiologic and clinical aspects of left bundle branch block, as well as current and future strategies for management.
Real‐world behavior of CRT pacing using the AdaptivCRT algorithm on patient outcomes: Effect on mortality and atrial fibrillation incidence

Journal of Cardiovascular Electrophysiology | February 3, 2020 | Volume: 31 | Issue: 4 | Pages: 825-833

10.1111/jce.14376 | PMID 32009263

AbstractBackgroundThe AdaptivCRT (aCRT) algorithm continuously adjusts cardiac resynchronization therapy (CRT) according to intrinsic atrioventricular conduction, providing synchronized left ventricular pacing in patients with normal PR interval and adaptive BiV pacing in patients with prolonged PR interval. Previous analyses demonstrated an association between aCRT and clinical benefit. We evaluated the incidence of patient mortality and atrial fibrillation (AF) with aCRT compared with standard CRT in a real‐world population.Methods and ResultsPatients enrolled in the Medtronic Personalized CRT Registry and implanted with a CRT from 2013‐2018 were divided into aCRT ON or standard CRT groups based upon device‐stored data. A Frailty survival model was used to evaluate the potential survival benefit of aCRT, accounting for patient heterogeneity and center variability. Daily AF burden and first device‐detected AF episodes of various durations were recorded by the device during follow‐up.A total of 1814 CRT patients with no reported long‐standing AF history at implant were included. Mean follow‐up time was 26.1 ± 16.5 months and 1162 patients (64.1%) had aCRT ON. Patient survival probability at 36 months was 88.3% for aCRT ON and 83.7% for standard CRT (covariate‐adjusted hazard ratio [HR] = 0.71, 95% CI: 0.53‐0.96, P = .028). Mean AF burden during follow‐up was consistently lower in aCRT ON patients compared with standard CRT. At 36 months, the probability of AF was lower in patients with aCRT ON, regardless of which AF definition threshold was applied (6 minutes‐30 days, all P < .001).ConclusionUse of the AdaptivCRT algorithm was associated with improved patient survival and lower incidence of AF in a real‐world, prospective, nonrandomized registry.
Temporal Occurrence of Arrhythmic Complications After Alcohol Septal Ablation

Circulation: Cardiovascular Interventions | January 24, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circinterventions.119.008540 | PMID 31973555

Background: The temporal occurrence of arrhythmic complications after alcohol septal ablation (ASA) is unclear. As a result, the appropriate time to monitor patients after ASA is controversial. The purpose of this study is to determine the temporal occurrence of complete heart block (CHB) and ventricular tachyarrhythmia (VT) after ASA to better understand when patients can be safely discharged. Methods: Consecutive patients treated with ASA for hypertrophic cardiomyopathy from 2003 to 2019 at a tertiary referral center were reviewed retrospectively. The incidence and timing of CHB or sustained VT within 30 days post-ASA were assessed. Results: A total of 243 patients were included in this study. Mean maximal septal thickness was 19.0±3.9 mm, and total volume of ethanol injected was 1.7±0.6 mL. CHB occurred in 59 (24.3%) patients, including transient CHB in 33 (13.6%) and permanent in 26 (10.7%). The initial episode of CHB occurred within 24 hours post-ASA in 51 (21.0%) patients, between 24 and 48 hours in 3 (1.2%), between 48 and 72 hours in 3 (1.2%), and after 72 hours in 2 (0.8%). New permanent pacemaker was placed in 46 (18.3%). Presence of baseline bundle branch block and age ≥70 were significantly associated with CHB but not CHB presenting after 24 hours. VT occurred in 3 (1.2%) patients, including 1 (0.4%) within 24 hours, 1 (0.4%) between 24 and 48 hours, and 1 (0.4%) after 72 hours. VT required cardioversion in 2 patients and new implantable cardioverter-defibrillator placement in 2. Conclusions: The incidence of CHB or VT presenting after 72 hours post-ASA was low. These findings suggest that timely discharge of patients without evidence of early conduction disturbances after ASA can be considered as a potentially safe management strategy, especially in patients without preexisting conduction abnormalities.
Utility of 30-Day Continuous Ambulatory Monitoring to Identify Patients With Delayed Occurrence of Atrioventricular Block After Transcatheter Aortic Valve Replacement

Circulation: Cardiovascular Interventions | December 13, 2019 | Volume: 12 | Issue: 12 | Pages: No page available

10.1161/circinterventions.118.007635 | PMID 31833417

Background: Mechanical injury in the conduction system requiring permanent pacemaker (PPM) associated with transcatheter aortic valve replacement (TAVR) procedure is a common complication. The objective of this study was to use ambulatory monitor BodyGuardian to assess late occurrence of atrioventricular block (AVB) after TAVR. Methods: This prospective study evaluated 365 patients who underwent TAVR at Mayo Clinic, Rochester, Minnesota between June 2016 and August 2017. Patients who received PPM for bradycardia after TAVR before discharge were considered as the PPM group. Those not requiring PPM received a BodyGuardian system (BodyGuardian group) for 30 days of continuous monitoring. Primary end point was Mobitz II or third-degree atrioventricular block (II/III AVB) at 30-day follow-up. Results: Of 365 patients, 74 who had a PPM or an implantable cardioverter-defibrillator before TAVR and 94 who were enrolled in other studies were excluded. Of 197 patients enrolled in the study, 70 (35.5%) received PPM and 127 had BodyGuardian before the hospital dismissal. Eleven of 127 (8.6%) BodyGuardian group required PPM within 30 days after TAVR for late occurrence of symptomatic bradycardia. In total, 33 of 197 (16.7%) patients developed II/III AVB (24 before and 9 after discharge). Thirty-four patients had preexisting right bundle branch block. Of them, 16 (47%) developed II/III AVB. Of 53 patients who developed new left bundle branch block after TAVR, 14% progressed to II/III AVB within 30 days. Conclusions: In patients without a standard post-TAVR pacing indication, yet a potential risk to develop AVB, a strategy of 30-day monitoring identifies additional patients who require permanent pacing.
Analysis of Temporal Trends and Variation in the Use of Defibrillation Testing in Contemporary Practice

JAMA Network Open | October 18, 2019 | Volume: 2 | Issue: 10 | Pages: e1913553

10.1001/jamanetworkopen.2019.13553 | PMID 31626314