Citations 41

Two-stage arthrodesis for complex, failed, infected total knee arthroplasty

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 170-175

10.1302/0301-620x.102b6.bjj-2019-1554.r1 | PMID 32475264

Aims Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients. Methods We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m2 (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%). Results Survivorship free from amputation, persistent infection, and reoperation, other than removal of an external fixator, at five years was 95% (95% confidence interval (CI) 89% to 100%), 85% (95% CI 75% to 95%), and 64% (95% CI 46% to 82%), respectively. Reoperation, other than removal of an external fixator, occurred in 13 patients (32%). After the initial treatment, radiological nonunion developed in ten knees (24%). Nonunion was significantly correlated with persistent infection (p = 0.006) and external fixation (p = 0.005). Of those patients who achieved limb salvage, 34 (87%) remained mobile and 31 (79%) had ‘absent’ or ‘minimal’ pain ratings. Conclusion Knee arthrodesis using a two-stage protocol achieved a survivorship free from amputation for persistent infection of 95% at five years with 87% of patients were mobile at final follow-up. However, early reoperation was common (32%). This is not surprising as this series included worst-case infected TKAs in which two-thirds of the patients had a disrupted EM, one-third required flap cover, and most had polymicrobial or multi-drug resistant organisms. Cite this article: Bone Joint J 2020;102-B(6 Supple A):170–175.
Excellent two-year survivorship of 3D-printed metaphyseal cones in revision total knee arthroplasty

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 107-115

10.1302/0301-620x.102b6.bjj-2019-1544.r1 | PMID 32475272

AimsMetaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system.MethodsWe reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m2(18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6).ResultsSurvivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully.ConclusionNovel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115.
Comparison of Porous Tantalum Acetabular Implants and Harrington Reconstruction for Metastatic Disease of the Acetabulum

Journal of Bone and Joint Surgery | May 26, 2020 | Volume: 102 | Issue: 14 | Pages: 1239-1247

10.2106/jbjs.19.01189 | PMID 32675673

Background: The periacetabular region is a common location for metastatic disease. Although large lytic acetabular defects are commonly treated with a hip arthroplasty with a cemented component according to a Harrington-style reconstruction, the use of highly porous uncemented tantalum acetabular components has been described. Currently, there are no direct comparisons of these reconstructive techniques. The purpose of this study was to compare the outcomes of the Harrington technique and tantalum acetabular component reconstruction for periacetabular metastases. Methods: From 2 tertiary sarcoma centers, we retrospectively reviewed 115 patients (70 female and 45 male) with an acetabular metastatic defect who had been treated between 2002 and 2015 with a total hip arthroplasty using either the cemented Harrington technique (78 patients) or a tantalum acetabular reconstruction (37 patients). The mean patient age was 61 years, and the most common Eastern Cooperative Oncology Group status was 3 (39 patients). The mean follow-up for surviving patients was 4 years. Results: An additional surgical procedure was performed in 24 patients (21%). Harrington-style reconstructions were more likely to require a reoperation compared with tantalum reconstructions (hazard ratio [HR], 4.59; p = 0.003). The acetabular component was revised in 13 patients (11%); 5 patients (4%) underwent revisions that were due to loosening of the acetabular component. The 10-year cumulative incidence of revision of the acetabular component for loosening was 9.6% in the Harrington group and 0% in the tantalum group (p = 0.09). The mean Harris hip score significantly improved following reconstruction (31 to 67 points; p < 0.001), with no significant difference (p = 0.29) between groups. Conclusions: In patients with periacetabular metastatic disease treated with total hip arthroplasty, an acetabular reconstruction strategy utilizing highly porous tantalum acetabular components and augments successfully provided patients with a more durable construct with fewer complications compared with the cemented Harrington-style technique. Levels of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Varus-valgus constraint in 416 revision total knee arthroplasties with cemented stems provides a reliable reconstruction with a low subsequent revision rate at early to mid-term review

The Bone & Joint Journal | March 31, 2020 | Volume: 102-B | Issue: 4 | Pages: 458-462

10.1302/0301-620x.102b4.bjj-2019-0719.r2 | PMID 32228079

AimsVarus-valgus constrained (VVC) implants are often used during revision total knee arthroplasty (TKA) to gain coronal plane stability. However, the increased mechanical torque applied to the bone-cement interface theoretically increases the risk of aseptic loosening. We assessed mid-term survivorship, complications, and clinical outcomes of a fixed-bearing VVC device in revision TKAs.MethodsA total of 416 consecutive revision TKAs (398 patients) were performed at our institution using a single fixed-bearing VVC TKA from 2007 to 2015. Mean age was 64 years (33 to 88) with 50% male (199). Index revision TKA diagnoses were: instability (n = 122, 29%), aseptic loosening (n = 105, 25%), and prosthetic joint infection (PJI) (n = 97, 23%). All devices were cemented on the epiphyseal surfaces. Femoral stems were used in 97% (n = 402) of cases, tibial stems in 95% (n = 394) of cases; all were cemented. In total, 93% (n = 389) of cases required a stemmed femoral and tibial component. Femoral cones were used in 29%, and tibial cones in 40%. Survivorship was assessed via competing risk analysis; clinical outcomes were determined using Knee Society Scores (KSSs) and range of movement (ROM). Mean follow-up was four years (2 to 10).ResultsThe five-year cumulative incidence of subsequent revision for aseptic loosening and instability were 2% (95% confidence interval (CI) 0.2 to 3, number at risk = 154) and 4% (95% CI 2 to 6, number at risk = 153), respectively. The five-year cumulative incidence of any subsequent revision was 14% (95% CI 10 to 18, number at risk = 150). Reasons for subsequent revision included PJI (n = 23, of whom 12 had previous PJI), instability (n = 13), and aseptic loosening (n = 11). The use of this implant without stems was found to be a significant risk factor for subsequent revision (hazard ratio (HR) 7.58 (95% CI 3.98 to 16.03); p = 0.007). KSS improved from 46 preoperatively to 81 at latest follow-up (p < 0.001). ROM improved from 96° prerevision to 108° at latest follow-up (p = 0.016).ConclusionThe cumulative incidence of subsequent revision for aseptic loosening and instability was very low at five years with this fixed-bearing VVC implant in revision TKAs. Routine use of cemented and stemmed components with targeted use of metaphyseal cones likely contributed to this low rate of aseptic loosening. Cite this article: Bone Joint J 2020;102-B(4):458–462.
Use of Povidone-Iodine Irrigation Prior to Wound Closure in Primary Total Hip and Knee Arthroplasty

Journal of Bone and Joint Surgery | July 11, 2019 | Volume: 101 | Issue: 13 | Pages: 1144-1150

10.2106/jbjs.18.01285 | PMID 31274715

Background: Povidone-iodine (PI) irrigation is often used prior to wound closure in total joint arthroplasty, but there are limited reports evaluating its efficacy in decreasing joint infections. The goal of this study was to compare the rate of any reoperation for infection (both superficial and deep) in primary total hip arthroplasty (THA) and primary total knee arthroplasty (TKA) among patients who did and did not receive PI irrigation prior to wound closure. Methods: Using our institution’s total joint registry, we identified 5,534 primary THA and 6,204 primary TKA procedures performed from 2013 to 2017. Cases were grouped on the basis of whether or not the wound was irrigated with 1 L of 0.25% PI prior to closure. PI irrigation was used in 1,322 (24%) of the THA cases and in 2,410 (39%) of the TKA cases. The rates of reoperation for infection at 3 months and 1 year were compared between the 2 groups. The same comparisons were then performed using propensity scores to account for differences in baseline characteristics. Results: The rate of reoperation for infection as assessed at 3 months following THA was similar between those who received dilute PI irrigation (0.9%) and who did not (0.7%) (p = 0.7). At 1 year, the rate of reoperation for infection was similar between those who received dilute PI irrigation (0.7%) and those who did not (0.9%) (p = 0.6). After using the propensity score, there was no difference between the groups in the risk of septic reoperations. For TKA, the rate of reoperation as assessed at 3 months was similar between those who received dilute PI irrigation (0.8%) and those who did not (0.3%) (p = 0.06). At 1 year, there was a greater rate of reoperations for infection among those who received dilute PI irrigation (1.2%) compared with those who did not (0.6%) (p = 0.03). However, there was no difference in the risk of septic reoperations between the groups after using the propensity score. Conclusions: Despite enthusiasm for and progressive adoption of the use of dilute PI irrigation at our institution, there was not a significant reduction in the risk of reoperation for infection as assessed at 3 months and 1 year following primary THA and TKA. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Povidone-Iodine Wound Lavage to Prevent Infection After Revision Total Hip and Knee Arthroplasty

Journal of Bone and Joint Surgery | July 11, 2019 | Volume: 101 | Issue: 13 | Pages: 1151-1159

10.2106/jbjs.18.01152 | PMID 31274716

Background: Postoperative infection remains a major challenge in revision total hip arthroplasty (THA) and revision total knee arthroplasty (TKA). Wound irrigation with dilute povidone-iodine (PI) solution has emerged as a simple, inexpensive, and potentially successful means of reducing postoperative infections. The aim of this study was to assess its effectiveness in reducing infection following revision THA and TKA in, to our knowledge, the largest revision cohort to date. Methods: Using our institution’s total joint registry, we identified 1,402 revision THAs and 1,482 revision TKAs performed during the study period (2013, when the PI irrigation protocol was first implemented, to 2017). The PI lavage protocol was employed in 27% of the revision THA cases and 34% of the revision TKA cases; in the remaining cases, the protocol was not used. Demographics, comorbid conditions, underlying surgical diagnoses, and whether the revision was for a septic or an aseptic etiology were compared between the groups (use or no use of PI irrigation). Any reoperation due to infection, as assessed at 3 and 12 months following revision arthroplasty, was compared between the groups and propensity scores were calculated to account for differences in baseline characteristics between the groups. Results: After adjusting for baseline differences between the groups using the propensity-score weighted models, we found no significant difference in the rate of reoperation for infection at 3 months (p = 0.58 for revision THA, and p = 0.06 for revision TKA) and at 12 months (p = 0.78 for revision THA, and p = 0.06 for revision TKA). Nonetheless, the hazard ratios from the propensity-score model trended higher for patients who received PI lavage: 1.6 and 1.3 for revision THA at 3 and 12 months, respectively, and 2.9 at both 3 and 12 months for revision TKA. Conclusions: PI wound lavage demonstrated no benefit in reducing any reoperation for infection following revision THA and TKA. Moreover, the trend toward higher rates for reoperation for infection among patients who received PI irrigation merit further consideration. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Extensor Mechanism Reconstruction with Use of Marlex Mesh

JBJS Essential Surgical Techniques | June 28, 2019 | Volume: 9 | Issue: 2 | Pages: e21

10.2106/jbjs.st.18.00106 | PMID 31579539

Background: Marlex mesh reconstruction of the extensor mechanism via a stepwise surgical approach is a viable option to treat disruption of the extensor mechanism after total knee arthroplasty (TKA). Description: Extensor mechanism reconstruction with mesh involves a stepwise surgical approach with a particular monofilament polypropylene mesh (Marlex; C.R. Bard). Prior to incision, the 10 × 14-in (25 × 36-cm) sheet of Marlex mesh is rolled onto itself 8 to 10 times and sewn together. If the tibia is not being revised, a burr is utilized to create a trough in the tibia. Five centimeters of the tapered portion of the mesh are predipped in bone cement. The remaining cement is inserted into the trough. The tapered portion of the mesh is inserted into the tibial trough, ensuring that the mesh is fully seated. After the cement has cured, a lag screw is placed across the mesh and cement and into host bone. If the tibia is being revised at the time of the Marlex mesh reconstruction, the 5 cm of predipped mesh is placed anteriorly in the medullary canal in line with the tibial crest. The remaining procedure is similar regardless of whether the components are revised. At the level of the joint, it is essential to ensure that the mesh is covered with host tissue. Next, the proximal reconstruction, which involves mobilizing the vastus lateralis and vastus medialis obliquus (VMO) distally by releasing all ventral and dorsal soft-tissue adhesions off the muscle bellies, is completed. Finally, the mesh is unitized to the vastus lateralis. With the limb maintained in full extension, the mesh is pulled directly proximally while another assistant pulls the vastus lateralis distally and medially. The vastus lateralis is deep, and the mesh is directly on top of it. Multiple nonabsorbable sutures are placed through the mesh and vastus lateralis. The VMO is then pulled distally and laterally over the mesh (which is now unitized to the vastus lateralis) by an assistant. Multiple nonabsorbable sutures (usually 8) are placed through the VMO, through the mesh, and through the vastus lateralis, unitizing the entire construct. Alternatives: Nonoperative treatments include a drop-lock hinge brace or knee immobilizer. Operative treatments include whole extensor mechanism allograft reconstruction or Achilles tendon allograft reconstruction. Rationale: The procedure avoids the limitations of allograft with regard to availability, cost, and risk of disease transmission. The technique is reproducible and cost-effective, and it has excellent functional and survivorship outcomes.
Total Knee Arthroplasty After High Tibial Osteotomy Results in Excellent Long-Term Survivorship and Clinical Outcomes

Journal of Bone and Joint Surgery | June 6, 2019 | Volume: 101 | Issue: 11 | Pages: 970-978

10.2106/jbjs.18.01060 | PMID 31169573

Background: Some prior reports of total knee arthroplasty after high tibial osteotomy have shown high rates of aseptic loosening. As such, the goal of this study was to analyze the outcomes of contemporary total knee arthroplasty after high tibial osteotomy, with particular emphasis on survivorship free from aseptic loosening, any revision, and any reoperation; complications; radiographic results; and clinical outcomes. Methods: We retrospectively reviewed 207 patients who underwent 231 total knee arthroplasties using cemented prostheses after high tibial osteotomy from 2000 to 2012 through our total joint registry: 87% were after a closing-wedge osteotomy and 13% were after an opening-wedge osteotomy. The mean follow-up from total knee arthroplasty was 8 years. At the time of the total knee arthroplasty, the mean age was 64 years and the mean body mass index was 31 kg/m 2 . The majority of total knee arthroplasties had a posterior-stabilized design (93%), and 4% had a varus-valgus constraint design. Tibial stems were utilized in 8% of cases. Bivariate and multivariate Cox regression analyses were utilized to analyze risk factors for poorer survival. Results: At 10 years, survivorship free from aseptic loosening was 97%, survivorship free from any revision was 90%, and survivorship free from any reoperation was 85%. Fifteen patients (15 total knee arthroplasties [6%]) underwent aseptic revision, most commonly for instability (3%), aseptic loosening (2%), and periprosthetic fracture (1%). On bivariate analysis, patient age of <60 years was a significant risk factor for poorer revision-free survival (hazard ratio, 2.9; p = 0.02); on multivariate analysis, younger age was the only significant risk factor for revision (p = 0.04). There were 14 complications (6%), the most common being a manipulation under anesthesia in 9 cases (4%). No unrevised total knee arthroplasties had definitive radiographic evidence of loosening. Knee Society scores improved from a mean preoperative score of 59 points to a mean postoperative score of 93 points (p < 0.001). Conclusions: Contemporary total knee arthroplasty with a cemented prosthesis after high tibial osteotomy demonstrated excellent long-term durability, with 10-year survivorship free from aseptic loosening of 97%. There was reliable improvement in clinical outcomes, but perfect knee balance was sometimes challenging, as reflected by a 4% prevalence of manipulation under anesthesia and a 3% prevalence of revision for instability. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Total knee arthroplasty after distal femoral osteotomy long-term survivorship and clinical outcomes

The Bone & Joint Journal | June 1, 2019 | Volume: 101-B | Issue: 6 | Pages: 660-666

10.1302/0301-620x.101b6.bjj-2018-1334.r2 | PMID 31154844

AimsThere is little literature about total knee arthroplasty (TKA) after distal femoral osteotomy (DFO). Consequently, the purpose of this study was to analyze the outcomes of TKA after DFO, with particular emphasis on: survivorship free from aseptic loosening, revision, or any re-operation; complications; radiological results; and clinical outcome.Patients and MethodsWe retrospectively reviewed 29 patients (17 women, 12 men) from our total joint registry who had undergone 31 cemented TKAs after a DFO between 2000 and 2012. Their mean age at TKA was 51 years (22 to 76) and their mean body mass index 32 kg/m2(20 to 45). The mean time between DFO and TKA was ten years (2 to 20). The mean follow-up from TKA was ten years (2 to 16). The prostheses were posterior-stabilized in 77%, varus-valgus constraint (VVC) in 13%, and cruciate-retaining in 10%. While no patient had metaphyseal fixation (e.g. cones or sleeves), 16% needed a femoral stem.ResultsThe ten-year survivorship was 95% with aseptic loosening as the endpoint, 88% with revision for any reason as the endpoint, and 81% with re-operation for any reason as the endpoint. Three TKAs were revised for instability (n = 2) and aseptic tibial loosening (n = 1). No femoral component was revised for aseptic loosening. Patients under the age of 50 years were at greater risk of revision for any reason (hazard ratio 7; p = 0.03). There were two additional re-operations (6%) and four complications (13%), including three manipulations under anaesthetic (MUA; 10%). The Knee Society scores improved from a mean of 50 preoperatively (32 to 68) to a mean of 93 postoperatively (76 to 100; p < 0.001).ConclusionA cemented posterior-stabilized TKA has an 88% ten-year survivorship with revision for any reason as the endpoint. No femoral component was revised for aseptic loosening. Patients under the age of 50 years have a greater risk of revision. The clinical outcome was significantly improved but balancing the knee was challenging in 13% of TKAs requiring VVC. Overall, 10% of TKAs needed an MUA, and 6% of TKAs were revised for instability. Cite this article: Bone Joint J 2019;101-B:660–666.
Two-Stage Revision of Total Hip Arthroplasty for Infection Is Associated with a High Rate of Dislocation

Journal of Bone and Joint Surgery | February 28, 2019 | Volume: 101 | Issue: 4 | Pages: 322-329

10.2106/jbjs.18.00124 | PMID 30801371

Background: Two-stage exchange is the most common form of treatment of chronic infection following total hip arthroplasty (THA). We examined the prevalence of, and risk factors associated with, hip instability following 2-stage exchange as well as the fate of reimplanted hip prostheses that dislocated. Methods: Data on 515 2-stage exchange THAs performed between 2000 and 2014 at a single institution were retrospectively reviewed. Risk factors for instability as well as postoperative reoperations and revisions were analyzed. The impact of dislocation on these outcomes was evaluated as well. The mean age at the time of reimplantation was 65 years, and the mean duration of follow-up was 5 years (range, 2 to 15 years). Results: Dislocation occurred in 52 hips following reimplantation (cumulative probability = 8.9% at 1 year). There was a higher risk of instability in women (hazard ratio [HR] = 1.8, p = 0.038) and in those who had a history of dislocation prior to the 2-stage revision (HR = 5.1, p < 0.001). Younger age, body mass index, number of previous operations, spacer type, surgical approach, use of a constrained liner, femoral head diameter, and persistent or recurrent infection were not found to be significant risk factors. Patients with an absent or ununited greater trochanter or abductor deficiency also had a higher rate of dislocation (HR = 30, p < 0.001), as did patients who underwent reimplantation with a megaprosthesis (HR = 6.0, p < 0.001). The risk of additional reoperations (HR = 121, p < 0.001) and revision surgery (HR = 13, p < 0.001) was significantly higher in patients who experienced a dislocation after the 2-stage exchange. Conclusions: Dislocation after 2-stage exchange THA continues to be a major concern, with the 1-year cumulative probability found to be 9% in the present study. Female sex, a history of dislocation, an absent or ununited greater trochanter or abductor deficiency, and reimplantation with a megaprosthesis were identified as risk factors for dislocation. There is a remarkable 121-fold increase in the rate of reoperations and a 13-fold increase in the rate of revisions in hips that dislocated after 2-stage exchange THA. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.