Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition

Open Heart | March 30, 2018 | Volume: 5 | Issue: 1 | Pages: e000681

10.1136/openhrt-2017-000681 | PMID 29632673

Objective To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. Methods We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. Results There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2–6) vs 2 (IQR 1–4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9–33.3) vs 19.5 months (IQR 1.1–62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). Conclusions CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket.
Attempted salvage of infected cardiovascular implantable electronic devices: Are there clinical factors that predict success?

Pacing and Clinical Electrophysiology | March 8, 2018 | Volume: 41 | Issue: 5 | Pages: 524-531

10.1111/pace.13319 | PMID 29518265

AbstractBackgroundPublished guidelines mandate complete device removal in cases of cardiovascular implantable electronic device (CIED) infection. Clinical predictors of successful salvage of infected CIEDs have not been defined.MethodsData from the Multicenter Electrophysiologic Device Infection Collaboration, a prospective, observational, multinational cohort study of CIED infection, were used to investigate whether clinical predictors of successful salvage of infected devices could be identified.ResultsOf 433 adult patients with CIED infections, 306 (71%) underwent immediate device explantation. Medical management with device retention and antimicrobial therapy was initially attempted in 127 patients (29%). “Early failure” of attempted salvage occurred in 74 patients (58%) who subsequently underwent device explantation during the index hospitalization. The remaining 53 patients (42%) in the attempted salvage group retained their CIED. Twenty‐six (49%) had resolution of CIED infection (successful salvage group) whereas 27 patients (51%) experienced “late” salvage failure. Upon comparing the salvage failure group, early and late (N = 101), to the group experiencing successful salvage of an infected CIED (N = 26), no clinical or laboratory predictors of successful salvage were identified. However, by univariate analysis, coagulase‐negative staphylococci as infecting pathogens (P = 0.0439) and the presence of a lead vegetation (P = 0.024) were associated with overall failed salvage.ConclusionsIn patients with definite CIED infections, clinical and laboratory variables cannot predict successful device salvage. Until new data are forthcoming, device explantation should remain a mandatory and early management intervention in patients with CIED infection in keeping with existing expert guidelines unless medical contraindications exist or patients refuse device removal.
Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infection

Pacing and Clinical Electrophysiology | February 7, 2018 | Volume: 41 | Issue: 5 | Pages: 495-503

10.1111/pace.13300 | PMID 29411401

AbstractBackgroundCardiac implantable electronic device (CIED) infection is a serious adverse event, but there are limited contemporary real‐world data on treatment pathways and associated costs in the Medicare population following diagnosis of CIED infection. Hence, this study evaluates postinfection treatment pathways and associated healthcare expenditures and mortality among Medicare fee‐for‐service beneficiaries with CIED infection.MethodsRetrospective cohort analysis of 5,401 beneficiaries who developed a device‐related infection in the year following implantation/upgraded CIED (1/1/2010–12/31/2012). Patients were followed‐up to 12 months/death following diagnosis of infection and were divided into mutually exclusive groups based on whether they underwent CIED system removal (Group I), or no CIED system intervention (Group II; IIA with or IIB without infection hospitalization). All‐cause healthcare resource utilization/expenditures were also measured.ResultsIn the year following infection, 64.1% of patients underwent device extraction, of who 2,109 (39.0%) had their device replaced (Group IA) and 1,355 (25.1%) had their device extracted without replacement (Group IB); 62.2% of patients were hospitalized and 25.3% of patients died. Mean Medicare payments‐per‐patient for facility‐based services by group were: IA = $62,638 (standard deviation [SD]: $46,830), IB = $50,079 (SD: $45,006), IIA = $77,397 (SD: $79,130), and IIB = $22,856 (SD: $31,167).ConclusionsHospitalizations were the largest cost driver; infection‐related costs, including cost of extraction/replacement, accounted for >50% of expenditures for patients with surgical/hospital intervention. Management of CIED infection in Medicare beneficiaries is associated with high healthcare expenditures in the year following infection. Additional measures to prevent device infection are needed to improve the outcomes and reduce costs in these patients.
Cranial neuropathy and severe pain due to early disseminated Borrelia burgdorferi infection

BMJ Case Reports | January 23, 2018 | Volume: 2018 | Issue: No issue available | Pages: bcr-2017-223307

10.1136/bcr-2017-223307 | PMID 29367377

A 61-year-old man presented to the emergency department in the summer with a right seventh cranial nerve lower motor neuron palsy and worsening paraesthesias for 6 weeks. He had debilitating pain at the scalp and spine. Prior work up was unrevealing. The patient resided in the upper Midwest region of the USA and worked outdoors, optimising the landscape for white tailed deer. Repeat cerebrospinal fluid testing revealed a lymphocytic pleocytosis and positive IgM Lyme serology. Brain MRI demonstrated enhancement of multiple cranial nerves bilaterally. He was diagnosed with early Lyme neuroborreliosis and treated with 28 days of intravenous ceftriaxone. While the painful meningoradiculitis, also known as Bannwarth syndrome, is more commonly seen in Europe, facial palsy is more frequently encountered in the USA. Clinical manifestations of neuroborreliosis are important to recognise as the classic presentation varies by geography and on occasion repeat serological testing may be necessary.
Cost-effectiveness of TYRX absorbable antibacterial envelope for prevention of cardiovascular implantable electronic device infection

Journal of Medical Economics | November 24, 2017 | Volume: 21 | Issue: 3 | Pages: 294-300

10.1080/13696998.2017.1409227 | PMID 29171319

Single Versus Multidrug Regimen for Surgical Infection Prophylaxis in Left Ventricular Assist Device Implantation

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 6 | Pages: 735-740

10.1097/mat.0000000000000710 | PMID 29095735

Infection is a serious complication of left ventricular assist device (LVAD) therapy. However, an optimal antimicrobial surgical infection prophylaxis (SIP) regimen for LVAD implantation is not well established. We retrospectively reviewed all adults who underwent continuous-flow LVAD implantation from February 2007 to March 2015 at Mayo Clinic Rochester. Left ventricular assist device infection (LVADI) was defined using criteria published by the International Society for Heart and Lung Transplant. Patients excluded from the analysis included those who did not have HeartMate II or HeartWare device, patients with incomplete documentation of SIP, and those with an actively treated infection at the time of LVAD implantation. We compared risk of LVAD-specific and LVAD-related infections and all-cause mortality between SIP regimens at postoperative day 90 and 1 year using Kaplan–Meier time-to-event analyses. During study period, 239 adults underwent continuous-flow LVAD implantation at our institution where 199 patients received single-drug and 40 received multidrug SIP regimen. Median patient age was 62 years. Left ventricular assist device infection occurred in three patients (1.5%) in the single-drug group versus two patients (5.0%) in the multidrug group at 90 days (p = 0.4). There was no difference in infection-free (p = 0.4) and overall survival (p = 0.9) between two groups at 1 year. In conclusion, there was no clear benefit of using multidrug regimen as it did not impact infection-free survival or all-cause mortality compared with single-drug regimen. Prospective clinical trials are needed to further define the optimal SIP regimen for LVAD implantation.
Left Ventricular Assist Device Infections: A Systematic Review

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 3 | Pages: 287-294

10.1097/mat.0000000000000684 | PMID 29095732

Left ventricular assist devices (LVADs) are becoming a more frequent life-support intervention. Gaining an understanding of risk factors for infection and management strategies is important for treating these patients. We conducted a systematic review and meta-analysis of studies describing infections in continuous-flow LVADs. We evaluated incidence, risk factors, associated microorganisms, and outcomes by type of device and patient characteristics. Our search identified 90 distinct studies that reported LVAD infections and outcomes. Younger age and higher body mass index were associated with higher rates of LVAD infections. Driveline infections were the most common infection reported and the easiest to treat with fewest long-term consequences. Bloodstream infections were not reported as often, but they were associated with stroke and mortality. Treatment strategies varied and did not show a consistent best approach. LVAD infections are a significant cause of morbidity and mortality in LVAD patients. Most research comes from secondary analyses of other LVAD studies. The lack of infection-oriented research leaves several areas understudied. In particular, bloodstream infections in this population merit further research. Providers need more research studies to make evidence-based decisions about the prevention and treatment of LVAD infections.
Clinical Manifestations and Outcome of Fluoroquinolone Associated Acute Interstitial Nephritis

Open Forum Infectious Diseases | October 4, 2017 | Volume: 4 | Issue: suppl_1 | Pages: S297-S297

10.1093/ofid/ofx163.684

Abstract Background Fluoroquinolones (FQ) are among the most commonly prescribed antibiotics. Nephrotoxicity related to FQ use is infrequently reported and the mechanism of renal injury is incompletely elucidated. We describe clinical manifestations and outcome of patients with biopsy proven acute interstitial nephritis (AIN) associated with FQ use at our institution. Methods We conducted a retrospective review of biopsy-proven AIN attributed to FQ use at Mayo Clinic Rochester from 1993 to 2016. Cases were reviewed by a renal pathologist and attributed to FQ use by an expert nephrologist. We also reviewed and summarized all published case reports of biopsy proven AIN that were attributed to FQ use. Results We identified 24 patients with FQ-related biopsy-proven AIN. The most commonly used FQ was ciprofloxacin (71%) with median antibiotic treatment duration of 7 days (Figure 1). The median duration between starting FQ and the diagnosis of AIN was 8.5 (IQR: 17). Common clinical manifestations included fever (50%), flank pain (8%), and skin rash (21%). However, 17% of the patients were asymptomatic at the time of diagnosis (Figure 2). Majority (58%) of the patients recovered following discontinuation of antibiotics and returned to baseline renal function at a median of 20.5 (IQR: 15.5). Six patients required temporary hemodialysis and 9 patients received steroids. Conclusion Onset of FQ-related AIN can be delayed and a high index of suspicion is needed by physicians prescribing these agents. Overall outcomes are favorable with recovery to baseline renal function within 3 weeks of discontinuing the offending drug. Disclosures All authors: No reported disclosures.
Isolated cerebral mucormycosis caused by Rhizomucor pusillus

BMJ Case Reports | October 4, 2017 | Volume: 2017 | Issue: No issue available | Pages: bcr-2017-221473

10.1136/bcr-2017-221473 | PMID 28978601

A 61-year-old man with relapsing chronic lymphocytic leukaemia, status post allogeneic stem cell transplant and multiple chemotherapy regimens presented to the emergency room after suffering a grand mal seizure. His evaluation revealed a 1.5–2 cm ring-enhancing left temporal lobe brain lesion on the CT scan. This brain lesion was resected and the histopathology revealed an invasive fungal organism resembling mucormycosis. Amplification and sequencing of the 28S ribosomal RNA gene identified the organism as Rhizomucor pusillus. The patient was treated with liposomal amphotericin B 5 mg/kg every 24 hours for 4 weeks, and then was transitioned to oral posaconazole. Serial brain imaging at 1 and 3 months, while on therapy, showed significant improvement.
International survey of knowledge, attitudes, and practices of cardiologists regarding prevention and management of cardiac implantable electronic device infections

Pacing and Clinical Electrophysiology | August 28, 2017 | Volume: 40 | Issue: 11 | Pages: 1260-1268

10.1111/pace.13183 | PMID 28846153

AbstractBackgroundCardiovascular implantable electronic devices (CIEDs) can be life‐saving. However, complications from CIED infection can be life‐threatening, often requiring device removal. Despite publication of CIED infection management guidelines, there remains marked variation in clinical practice.ObjectiveTo better understand and quantify these differences, we conducted a multinational survey of practitioners of CIED management.MethodsAn electronic survey was sent to Heart Rhythm Society members, spanning 70 countries across six continents. All responses were collected anonymously.Results227 out of 3,600 (6.3%) responded to the survey. The majority of surveys were completed by practitioners from the United States (168; 68.3%) and 53.8% of these practiced in academic medical centers. The large majority (92.7%) of sites had protocols to ensure appropriate timing of prophylactic antibiotics. Superficial (incisional) site infections were treated with antibiotics alone 52.5% of the time (consistent with guidelines); in contrast, deep pocket infections were treated with antibiotics (with device removal) in accordance to guidelines only 37.4% of the time. Almost all providers (98.7%) were inclined to perform complete hardware removal in cases of CIED‐related endocarditis. In contrast, 82.2% of survey participants suggested complete CIED system removal in patients with an occult Gram‐positive bacteremia, 65.5% with occult Gram‐negative bacteremia, and 59.3% with prolonged bacteremia due to a source other than CIED.ConclusionsThese data suggest wide variability in clinical practice in managing CIED infection with significant deviations from published guidelines. There is critical need to increase awareness and develop institutional protocols to ensure adherence with evidence‐based guidelines to optimize outcomes.