Citations 110

Discriminative Ability and Reliability of Transesophageal Echocardiography in Characterizing Cases of Cardiac Device Lead Vegetations Versus Noninfectious Echodensities

Clinical Infectious Diseases | April 22, 2020 | Volume: 72 | Issue: 11 | Pages: 1938-1943

10.1093/cid/ciaa472 | PMID 32533828

Abstract Background Approximately one-third of cases of cardiovascular implantable electronic device (CIED) infection present as CIED lead infection. The precise transesophageal echocardiographic (TEE) definition and characterization of “vegetation” associated with CIED lead infection remain unclear. Methods We identified a sample of 25 consecutive cases of CIED lead infection managed at our institution between January 2010 and December 2017. Cases of CIED lead infection were classified using standardized definitions. Similarly, a sample of 25 noninfected patients who underwent TEE that showed a defined lead echodensity during the study period was included as a control group. TEEs were reviewed by 2 independent echocardiologists who were blinded to all linked patient demographic, clinical, and microbiological information. Reported echocardiographic variables of the infected vs noninfected cases were compared, and the overall diagnostic performance was analyzed. Results Descriptions of lead echodensities were variable and there were no significant differences in median echodensity diameter or mobility between infected vs noninfected groups. Among infected cases, blinded echocardiogram reports by either reviewer correctly made a prediction of infection in 6 of 25 (24%). Interechocardiologist agreement was 68%. Sensitivity of blinded TEEs ranged from 31.5% to 37.5%. Conclusions Infectious vs noninfectious lead echodensities could not be reliably distinguished on the basis of size, mobility, and general shape descriptors obtained from a retrospective blinded TEE examination without knowledge of clinical and microbiological parameters. Therefore, a reanalysis of criteria used to support a diagnosis of CIED lead infection may be warranted.
Resource utilization associated with hospital and office-based insertion of a miniaturized insertable cardiac monitor: results from the RIO 2 randomized US study

Journal of Medical Economics | March 24, 2020 | Volume: 23 | Issue: 7 | Pages: 706-713

10.1080/13696998.2020.1746548 | PMID 32207636

Preclinical evaluation of efficacy and pharmacokinetics of gentamicin containing extracellular‐matrix envelope

Pacing and Clinical Electrophysiology | February 18, 2020 | Volume: 43 | Issue: 3 | Pages: 341-349

10.1111/pace.13888 | PMID 32067241

Abstract Background Using synthetic antibiotic‐eluting envelope (ABE) is an effective intervention for prevention of cardiovascular implantable electronic device (CIED) infection. The biologic extracellular‐matrix envelope (ECME), may offer potential advantages over the synthetic ABE. To further minimize the risk of infection, the ECME can be hydrated in gentamicin prior to CIED implantation. We aimed to evaluate the efficacy and pharmacokinetics (PK) of gentamicin containing ECME in an animal model. Methods For all experiments, the ECME was hydrated in gentamicin (40 mg/Ml) (treatment) for 2 min. In vitro antimicrobial efficacy against six different bacterial species was assessed. In vivo experiments were conducted using a rabbit model of CIED pocket infection. Serum and ECM gentamicin concentrations were measured. Five different organisms were inoculated into the device pocket of control (ECME hydrated in 0.9% saline) and treatment groups. Macroscopic appearance and colony forming units from CIED, ECME, and tissue were determined. Results No bacteria were recovered from any culture after 12 h of exposure to the gentamicin containing ECME. Serum gentamicin levels dropped below the limit of quantification at 15 h after implant. Gentamicin concentration in the ECME remained relatively stable for up to 7 days. Signs of clinical infection were observed in the control but not in the treatment group. In the presence of gentamicin, statistically significant reduction was demonstrated across all tested bacterial species. Conclusions In this preclinical animal infection model, gentamicin containing ECME was highly effective in reducing bacterial burden in the implant pocket, while systemic exposure after implantation remained low.
Reduced bacterial adhesion with parylene coating: Potential implications for Micra transcatheter pacemakers

Journal of Cardiovascular Electrophysiology | February 3, 2020 | Volume: 31 | Issue: 3 | Pages: 712-717

10.1111/jce.14362 | PMID 32009284

Abstract Introduction Infections of cardiac implantable electronic devices remain a prevalent health concern necessitating the advent of novel preventative strategies. Based on the observation that bacterial infections of the Micra transcatheter pacemaker device are extremely rare, we examine the effect of parylene coating on bacterial adhesion and growth. Methods Bacterial growth was compared on polyurethane coated, bare, or parylene coated titanium surfaces. Eight test samples per bacterial species and material combination were incubated with Staphylococcus Aureus or Pseudomonas aeruginosa for 24 hours and then assayed for bacterial growth. The surface contact angle was also characterized by measuring the angle between the tangent to the surface of a liquid droplet made with the surface of the solid sample. Results The mean bacterial colony counts were significantly reduced for both parylene coated titanium versus bare samples (3.69 ± 0.27 and 4.80 ± 0.48 log[CFU/mL] respectively for S. aureus [ P < .001] and 5.51 ± 0.27 and 6.08 ± 0.11 log[CFU/mL] respectively for P. aeruginosa [ P < .001]), and for parylene coated titanium versus polyurethane samples (4.27 ± 0.42 and 5.40 ± 0.49 log[CFU/mL] respectively for S. aureus [ P < .001] and 4.23 ± 0.42 and 4.84 ± 0.32 log[CFU/mL] respectively for P. aeruginosa [ P = .006]). Parylene coated titanium samples had a higher contact angle compared with bare titanium, but lower compared with polyurethane (mean contact angle 87.5 ± 3.1 degrees parylene, 73.3 ± 3.7 degrees titanium [ P < .001 vs parylene], and 94.8 ± 3.7 degrees polyurethane [ P = .002 vs parylene]). Conclusions Parylene coating significantly reduced the ability of bacteria to grow in colony count assays suggesting that this could contribute to the reduction of bacterial infections of Micra transcatheter pacemakers.
Fishing for a Diagnosis, the Impact of Delayed Diagnosis on the Course of Mycobacterium marinum Infection: 21 Years of Experience at a Tertiary Care Hospital

Open Forum Infectious Diseases | January 4, 2020 | Volume: 7 | Issue: 1 | Pages: No page available

10.1093/ofid/ofz550 | PMID 31988976

AbstractBackgroundMycobacterium marinum is a common but underreported mycobacterial infection. We conducted a large retrospective study to determine risk factors and describe the therapeutic interventions and outcomes in patients with uncomplicated and complicated M. marinum infection.MethodsCulture-confirmed M. marinum infection cases were identified from the Mayo Clinic Clinical Mycology Laboratory from January 1998 to December 2018. Complicated M. marinum infection was defined as the presence of tenosynovitis, septic arthritis, or osteomyelitis. Differences in complicated vs uncomplicated M. marinum infections were analyzed using statistical comparisons.ResultsTwelve cases had a complicated M. marinum infection. Patients with a complicated infection were older (64.3 ± 11.1 vs 55.8 ± 14.5; P = .03), had longer duration of symptoms (5 vs 3 months; P = .011), and had more surgical debridements (1 vs 0; P &lt; .001). Length of treatment and number of drugs used were not statistically significant. Complicated M. marinum cases received more medications (2 vs 1; P = .263) and were treated longer (5.7 vs 3.5 months; P = .067). Antibiotic susceptibilities were performed in 59% of the patients. All isolates were susceptible to clarithromycin. From the tetracyclines, doxycycline had a better susceptibility pattern.ConclusionsM. marinum infection is an important cause of skin and soft tissue infection. Poor water exposure documentation, unusual clinical presentation, and empiric antibiotic treatment before definitive M. marinum diagnosis often contribute to a delayed diagnosis. Complicated M. marinum cases had longer duration of symptoms and more surgical debridements. No difference in the number of drugs used or clinical outcome was observed.
290. Hepatitis E Virus Serostatus: A Retrospective Assessment of Demographics and Comorbidities to Assess High-risk Populations

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S158-S158

10.1093/ofid/ofz360.365

Abstract Background Demographic and epidemiologic characteristics of Hepatitis E virus (HEV) infected patients in the United States are not well-described. HEV infection may result in severe complications and lead to chronic infection and cirrhosis, especially in immunocompromised patients. There are no widely accepted guidelines for HEV screening and testing in the United States. Identifying traits of known seropositive patients and comorbidities may inform better screening and prevention strategies. In this study, we describe rates of liver disease, transplant status, chronic kidney diseases, and diabetes mellitus among patients serologically tested for HEV at our institution. Methods We retrospectively reviewed all patients for whom HEV IgM or IgG serologic testing was performed across the Mayo Clinic enterprise using the Advanced Cohort Explorer tool. For patients with any documented HEV serologic test, we abstracted baseline patient characteristics and underlying comorbidities at the time of testing. We then grouped subjects according to serologic testing results by antibody type. Survival at one year from date of testing was also assessed. Results A total of 979 unique subjects were identified. The preponderance of subjects was Caucasian (781, 79.8%). Of subjects tested for HEV with serology, 123 (12.6%) had any positive serology. Breakdown of baseline characteristics and selected comorbidities are summarized in Table 1. The largest proportion of subjects, 458 (46.8%), were both IgG and IgM negative and 432 subjects received only IgM or IgG testing. Liver disease was more prevalent in patients with positive vs. negative testing (5.8% vs. 2.1%) as was higher age (average 55.1 years vs. 52.2). One-year survival was similar in all groups. Conclusion HEV serology is not commonly tested. Among those tested, seropositivity is uncommon. Our data show higher HEV seropositivity in older adults, which may represent increase risk of exposure over time. Higher percentage of positive testing was also observed in subjects with liver disease, which may indicate a possible etiologic association. Further population-based studies are needed to estimate prevalence of HEV infection and associated liver disease, outcomes in infected patients, and indications for testing in at-risk populations. Disclosures All authors: No reported disclosures.
427. Putting the ‘Eye’ in Spirochetes

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S214-S214

10.1093/ofid/ofz360.500

Abstract Background Ocular syphilis is an infrequent presentation of Treponema pallidum infection. It is often seen in association with neurosyphilis but can occur in isolation as well. Here we describe a case series of 10 patients with ocular syphilis seen at our institution. Methods Patients with a diagnosis of ocular syphilis at the three sites of Mayo Clinic were identified from June 2006 to February 2019. Patient’s baseline characteristics, clinical presentation, diagnostic testing, and treatment were abstracted from Electronic Medical Records. Results We identified 10 patients (17 eyes) during the study period, half being diagnosed in the last 5 years. The median age was 51 years (IQR 21–66), and the majority were males (7/10). Characteristics of the patients are outlined in Table 1. Common presenting symptoms included vision loss (8/10), photophobia (4/10), and irritation (5/10). Seven of 10 patients had bilateral involvement. Of the 17 eyes, 59% had pan-uveitis and 82% had disc edema (Table 2). Rapid Plasma Reagin (RPR) was positive in 9 patients and median serum RPR was 1:128 (IQR 1:2-1:1024). One patient was diagnosed with a positive TP-PA, and characteristic ocular findings. One patients had positive 16S Ribosomal RNA Gene PCR/Sanger Sequencing on vitreous humor specimen for Treponema species. The majority of patients had isolated ocular symptoms at presentation; two patients also had an associated skin rash. All patients underwent a lumbar puncture (LP). Half had pleocytosis (TNC > 5) and elevated protein elevated (mean 63.6 mg/dL), although not significantly high. 3/10 patients had VDRL positive in the CSF. Protein levels were much higher in those with positive VDRL. Each patient was treated with intravenous (IV) penicillin for at least 2 weeks. Nine patients received ocular steroids as well. At last available follow-up, 8 had complete and 1 had partial resolution. One had worsened eye findings with eventual scarring. Conclusion Our findings are congruent with increasing incidence of ocular syphilis nationwide. Bilateral eye involvement and pan-uveitis were the most common ocular findings. Although only 3 patients had a positive VDRL in the CSF, pleocytosis and elevated protein were found in a large number of patients. Majority of the patients had clinical resolution with appropriate treatment. Disclosures All authors: No reported disclosures.
849. Reduced CIED Infections with an Antibacterial Envelope: Microbiologic Analysis of the WRAP-IT Study

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S16-S16

10.1093/ofid/ofz359.034

Abstract Background Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity, mortality, and cost. There is limited evidence on antibiotic prophylactic strategies to prevent CIED infection. Recently, the TYRX Envelope, which elutes a combination of rifampin and minocycline for a minimum of 7 days, was shown to significantly reduce major CIED infections in the WRAP-IT trial. We sought to characterize the pathogens among patients who experienced an infection in the current era. Methods All patients undergoing CIED replacement, upgrade, revision, or de novo cardiac resynchronization therapy (CRT-D) received standard of care antibiotic prophylaxis and were randomized 1:1 to receive TYRX or not. The primary endpoint was major CIED infection within 12 months of the procedure. Major infection was defined as an infection resulting in (1) system extraction or revision, (2) long-term suppressive antibiotic therapy, or (3) death. Data were analyzed using the Cox proportional hazards regression model. Results A total of 6,983 patients were randomized worldwide with 3,495 randomized to receive an envelope and 3,488 randomized to the control. At 12 months, 25 major infections (0.7%) were observed in the envelope group and 42 major infections (1.2%) in the control group, resulting in a 40% reduction of major infections (HR: 0.60, 95% CI: 0.36–0.98, P = 0.04). Of 63 infections assayed, causative pathogens were identified in 36 infections whereas cultures were negative in 27 cases. Staphylococcus species (n = 22) were the predominate pathogens and a 53% reduction was observed with the use of TYRX (Figure 1). Moreover, there was only 1 CIED pocket infection with Staphylococcus species in the envelope group compared with 14 pocket infections in the control group. A comparison of timing of infection in the envelope group showed the presence of 11 endocarditis/bacteremia infections at 103 ± 84 days compared with 14 pocket infections presenting at 70 ± 78 days from the procedure. Conclusion In this large randomized trial, the use of the TYRX Envelope containing rifampin and minocycline resulted in a significant reduction of major CIED infections and was effective against staphylococcal species, which are the predominant cause of pocket infections. Disclosures All Authors: No reported Disclosures.
1834. Incremental Diagnostic Value of 16S Ribosomal RNA Gene Polymerase Chain Reaction/Sanger Sequencing in Clinical Practice

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S44-S44

10.1093/ofid/ofz359.096

Abstract Background Polymerase chain reaction (PCR)/sequencing targeting the 16S ribosomal RNA (rRNA) gene to detect bacteria in normally sterile tissues and fluids has become increasingly popular in clinical medicine. This culture-independent technique can detect bacteria that are nonviable or difficult to cultivate using conventional methods. The clinical value of this type of testing is not well defined. We aimed to assess the diagnostic value of 16S rRNA PCR/Sanger sequencing as a clinical diagnostic assay at Mayo Clinic. Methods This is an interim analysis of the first 173 of 478 patients who had 16S rRNA PCR/Sanger sequencing done on sterile tissues or fluids at our institution from April, 2017 to November, 2018 as part of routine clinical practice. Medical records are being retrospectively reviewed, with results compared with those of culture. Results We reviewed 207 specimens from 173 patients (musculoskeletal 79%, cardiovascular 7%, central nervous system 4%, other 9%) that underwent 16S rRNA PCR/Sanger sequencing by clinical request (Table 1). In 90% of these specimens, the test was pre-planned rather than added-on. Nine specimens were excluded from analysis, as cultures were not performed. Overall concordance of culture with PCR/sequencing was 81% (160/197; P < 0.0001). Of 44 culture-positive specimens, PCR detected the same bacterium in 21 (48%) (Table 2). 45% (20/44) of those with positive cultures and 46% of those with positive PCR/sequencing results had received prior antimicrobial therapy (Table 3). PCR was negative in 139/144 specimens that were culture-negative (97%). PCR/sequencing was helpful in detecting a putative bacterial pathogen in 4 patients with negative cultures (Table 4). Conclusion Overall, 16S rRNA PCR/Sanger sequencing improved diagnostic yield compared with culture in a minority of cases. The described assay is limited by its inability to detect polymicrobial infections, a technical limitation that could possibly be addressed using massive parallel sequencing. Careful selection of cases and a save and add-on approach may be more cost-effective than upfront testing, although this was requested in a minority of cases. Disclosures Robin Patel, MD, ASM and IDSA: Other Financial or Material Support, Travel reimbursement, editor’s stipends; CD Diagnostics, Merck, Hutchison Biofilm Medical Solutions, Accelerate Diagnostics, ContraFect, TenNor Therapeutics Limited, Shionogi: Grant/Research Support; Curetis, Specific Technologies, NextGen Diagnostics, PathoQuest, Qvella: Consultant; NBME, Up-to-Date, the Infectious Diseases Board Review Course: Honorarium recipient, Other Financial or Material Support; Patent on Bordetella pertussis/parapertussis PCR issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, and a patent on an anti-biofilm substance issued: Other Financial or Material Support, Patents.
660. Extraction-Free 16S Ribosomal RNA (rRNA) Gene Amplification and Sequencing from Resected Cardiac Implantable Electronic Device (CIED) Sonicate Fluid

Open Forum Infectious Diseases | October 23, 2019 | Volume: 6 | Issue: Supplement_2 | Pages: S302-S303

10.1093/ofid/ofz360.728

Abstract Background We recently demonstrated that 16S rRNA PCR/sequencing performed on biofilms dislodged from extracted CIEDs into a salt solution—referred to as “sonicate fluid’ (SF)—may be used to detect pathogens in culture-negative CIED infection (Clinical Infectious Diseases, ciz266, doi:10.1093/cid/ciz266). The method we described included a DNA extraction/purification step, which can be time consuming and costly. Here, we evaluated an extraction-free approach to 16S rRNA gene PCR/sequencing. Methods 28 SF samples derived from explanted clinically-infected CIEDs were tested. Cases were categorized as “culture-positive” (C-P) if ≥20 cfu/10 mL were recovered, and as “culture-negative” (C-N), if <20 cfu/10 mL were detected in SF culture. The extraction-free method consisted of a single step of lysis at 1,000 rpm, 95°C for 5 minutes using an Eppendorf ThermoMixer®. DNA extraction (the comparator method) was performed using the ZymoBIOMICSTM Kit with modifications. Samples were processed using both methods, followed by amplification of the 16S rRNA gene and bidirectional Sanger sequencing. Crossing points (CPs) generated by the two approaches were compared. Organisms detected by the two PCR methods were compared with those detected with culture. Results Of the 28 samples tested, 13 were C-N and 15 C-P. The extraction-free method generated an amplicon in 13/15 C-P cases, with CPs ranging from 26 to 36 cycles vs. 100% (15/15) detected with the DNA extraction method and Cps of 19 to 32. Usable sequence length for the extraction-free method was of 359 (interquartile range, 307–390) vs. 390 (interquartile range, 308–396) base pairs with DNA extraction. Genus-level concordance between bacteria detected by culture in C-P samples and those found using the extraction-free and extraction methods was 92% (12/13) and 93% (14/15), respectively. Bacteria were detected by the extraction method in 2/13 C-N specimens, with none detected with an extraction-free method. Conclusion The described extraction-free method may be suitable for testing SF derived from CIEDs using 16S rRNA gene PCR/sequencing, saving time and cost. More studies are needed to establish clear cutoffs for interpretation of results and to assess for PCR inhibitors in the studied specimen-type. Disclosures Robin Patel, MD, ASM and IDSA: Other Financial or Material Support, Travel reimbursement, editor’s stipends; CD Diagnostics, Merck, Hutchison Biofilm Medical Solutions, Accelerate Diagnostics, ContraFect, TenNor Therapeutics Limited, Shionogi: Grant/Research Support; Curetis, Specific Technologies, NextGen Diagnostics, PathoQuest, Qvella: Consultant; NBME, Up-to-Date, the Infectious Diseases Board Review Course: Honorarium recipient, Other Financial or Material Support; Patent on Bordetella pertussis/parapertussis PCR issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, and a patent on an anti-biofilm substance issued: Other Financial or Material Support, Patents.