Back to Authors

Bartúnek, Jozef

https://orcid.org/0000-0002-4927-1632

A5038774828 | I4210101486

Mayo Clinic

Onze Lieve Vrouwziekenhuis Hospital

Citations 13

Cardiopoietic Index Predicts Heart Repair Fitness of Patient-Derived Stem Cells

Biomarkers in Medicine | May 27, 2015 | Volume: 9 | Issue: 7 | Pages: 639-649

10.2217/bmm.15.31 | PMID 26014833

Optimized Delivery System Achieves Enhanced Endomyocardial Stem Cell Retention

Circulation: Cardiovascular Interventions | December 11, 2013 | Volume: 6 | Issue: 6 | Pages: 710-718

10.1161/circinterventions.112.000422 | PMID 24326777

Background— Regenerative cell-based therapies are associated with limited myocardial retention of delivered stem cells. The objective of this study is to develop an endocardial delivery system for enhanced cell retention. Methods and Results— Stem cell retention was simulated in silico using 1- and 3-dimensional models of tissue distortion and compliance associated with delivery. Needle designs, predicted to be optimal, were accordingly engineered using nitinol, a nickel and titanium alloy displaying shape memory and superelasticity. Biocompatibility was tested with human mesenchymal stem cells. Experimental validation was performed with species-matched cells directly delivered into Langendorff-perfused porcine hearts or administered percutaneously into the endocardium of infarcted pigs. Cell retention was quantified by flow cytometry and real-time quantitative polymerase chain reaction methodology. Models, computing optimal distribution of distortion calibrated to favor tissue compliance, predicted that a 75°-curved needle featuring small-to-large graded side holes would ensure the highest cell retention profile. In isolated hearts, the nitinol curved needle catheter (C-Cath) design ensured 3-fold superior stem cell retention compared with a standard needle. In the setting of chronic infarction, percutaneous delivery of stem cells with C-Cath yielded a 37.7±7.1% versus 10.0±2.8% retention achieved with a traditional needle without effect on biocompatibility or safety. Conclusions— Modeling-guided development of a nitinol-based curved needle delivery system with incremental side holes achieved enhanced myocardial stem cell retention.
Left Ventricular Systolic Dysfunction, Heart Failure, and the Risk of Stroke and Systemic Embolism in Patients With Atrial Fibrillation

Circulation: Heart Failure | April 11, 2013 | Volume: 6 | Issue: 3 | Pages: 451-460

10.1161/circheartfailure.112.000143 | PMID 23575255

Background— We examined the risk of stroke or systemic embolism (SSE) conferred by heart failure (HF) and left ventricular systolic dysfunction (LVSD) in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation Trial (ARISTOTLE), as well as the effect of apixaban versus warfarin. Methods and Results— The risk of a number of outcomes, including the composite of SSE or death (to take account of competing risks) and composite of SSE, major bleeding, or death (net clinical benefit) were calculated in 3 patient groups: (1) no HF/no LVSD (n=8728), (2) HF/no LVSD (n=3207), and (3) LVSD with/without symptomatic HF (n=2736). The rate of both outcomes was highest in patients with LVSD (SSE or death 8.06; SSE, major bleeding, or death 10.46 per 100 patient-years), intermediate for HF but preserved LV systolic function (5.32; 7.24), and lowest in patients without HF or LVSD (1.54; 5.27); each comparison P <0.0001. Each outcome was less frequent in patients treated with apixaban: in all ARISTOTLE patients, the apixaban/warfarin hazard ratio for SSE or death was 0.89 (95% confidence interval, 0.81–0.98; P =0.02); for SSE, major bleed, or death it was 0.85 (0.78–0.92; P <0.001). There was no heterogeneity of treatment effect across the 3 groups. Conclusions— Patients with LVSD (with/without HF) had a higher risk of SSE or death (but similar rate of SSE) compared with patients with HF but preserved LV systolic function; both had a greater risk than patients without either HF or LVSD. Apixaban reduced the risk of both outcomes more than warfarin in all 3 patient groups. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00412984.