Citations 59

Circulating Chromogranin A as a Surveillance Biomarker in Patients with Carcinoids—The CASPAR Study

Clinical Cancer Research | October 25, 2024 | Volume: 30 | Issue: 24 | Pages: 5559-5567

10.1158/1078-0432.ccr-24-1875 | PMID 39453770

Abstract Purpose: Gastroenteropancreatic neuroendocrine tumors (GEP-NET) are relatively indolent but can be more aggressive. The current recommendations for using serum chromogranin A (CgA) for patients with GEP-NET are equivocal. This study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Patients and Methods: A prospective, multicenter, blinded observational study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Tumor progression was evaluated with RECIST 1.1 by CT/MRI. An increase ≥50% above the prior CgA concentration to a value >100 ng/mL in the following CgA concentration was considered positive. Results: A total of 153 patients with GEP-NET were enrolled. Using the prespecified cut-off of CgA change for tumor progression, specificity was 93.4% (95% confidence interval, 90.4%–95.5%; P < 0.001), sensitivity 34.4% (25.6%–44.3%), positive predictive value 57.9% (45.0–69.8), negative predictive value 84.3% (80.5–87.6), and AUC 0.73 (0.67–0.79). Conclusions: Changes in serial measurements of serum CgA had a favorable specificity and negative predictive value, making this test a useful adjunct to routine radiographic monitoring.
Total Copper and Labile Bound Copper Fraction as a Selective and Sensitive Tool in the Evaluation of Wilson Disease

The Journal of Applied Laboratory Medicine | September 3, 2024 | Volume: 9 | Issue: 6 | Pages: 1014-1027

10.1093/jalm/jfae090 | PMID 39225046

Abstract Background A dual filtration-based method for determination of serum labile bound copper (LBC) and LBC fraction (LBC/total copper) was developed. Reduced total copper, elevated LBC, and elevated LBC fraction have been reported in Wilson disease (WD). Methods To evaluate the diagnostic performance of these markers, samples were obtained from 21 WD treatment-naïve (WD-TN, no WD treatment or <28 days of treatment) patients, 46 WD standard-of-care–treated (WD-SOC) patients, along with 246 patients representing other potential disorders of copper status. These were then compared to 213 reference interval population patients. Results Receiver operating characteristic curves for the reference population vs WD-TN yielded areas under the curve for total copper, LBC, and LBC fraction, of 0.99, 0.81, and 0.98, respectively. Using Youden cutoffs, sensitivity/specificity for WD-TN was 95%/97% for total copper, 71%/85% for LBC, and 95%/94% for LBC fraction. LBC values, but not total copper and LBC fraction, differed substantially between WD-TN and WD-SOC cohorts. We propose a dual model wherein total copper and LBC fraction results must agree to be classified as a “positive” or “negative” result for WD. This correctly classified 19/21 WD-TN patients as positive, and 194/213 reference interval patients as negative. The remaining “indeterminate” patients (representing approximately 9% of the reference and the WD-TN populations) exhibited conflicting total copper and LBC fraction results. When indeterminate results are excluded, this model exhibited apparent 100% sensitivity/specificity. Conclusions Agreement of total serum copper and LBC fraction classification may constitute an effective “rule-in” and “rule-out” assessment for WD-TN patients.
Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination

Laboratory Medicine | August 13, 2024 | Volume: 56 | Issue: 1 | Pages: 64-69

10.1093/labmed/lmae067 | PMID 39136221

Abstract Background Due to the ability of metal ions to cross the blood–brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron. Methods Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels. Results No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested. Conclusions Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.
Optimizing cutpoints for clinical interpretation of brain amyloid status using plasma p‐tau217 immunoassays

Alzheimer's & Dementia | July 19, 2024 | Volume: 20 | Issue: 9 | Pages: 6506-6516

10.1002/alz.14140 | PMID 39030981

Abstract INTRODUCTION We aimed to evaluate clinical interpretation cutpoints for two plasma phosphorylated tau (p‐tau)217 assays (ALZpath and Lumipulse) as predictors of amyloid status for implementation in clinical practice. METHODS Clinical performance of plasma p‐tau217 against amyloid positron emission tomography status was evaluated in participants with mild cognitive impairment or mild dementia ( n = 427). RESULTS Using a one‐cutpoint approach (negative/positive), neither assay achieved ≥ 90% in both sensitivity and specificity. A two‐cutpoint approach yielding 92% sensitivity and 96% specificity provided the desired balance of false positives and false negatives, while categorizing 20% and 39% of results as indeterminate for the Lumipulse and ALZpath assays, respectively. DISCUSSION This study provides a systematic framework for selection of assay‐specific cutpoints for clinical use of plasma p‐tau217 for determination of amyloid status. Our findings suggest that a two‐cutpoint approach may have advantages in optimizing diagnostic accuracy while minimizing potential harm from false positive results. Highlights Phosphorylated tau (p‐tau)217 cutpoints for detection of amyloid pathology were established. A two‐cutpoint approach exhibited the best performance for clinical laboratory use. p‐tau217 assays differed in the percentage of results categorized as intermediate.
Proteomic Identification of Plasma Proteins Associated with Future Dementia Development

Clinical Chemistry | May 14, 2024 | Volume: 70 | Issue: 9 | Pages: 1092-1095

10.1093/clinchem/hvae004 | PMID 38741526

Performance of the Lumipulse plasma Aβ42/40 and pTau181 immunoassays in the detection of amyloid pathology

Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring | February 1, 2024 | Volume: 16 | Issue: 1 | Pages: No page available

10.1002/dad2.12545 | PMID 38304322

AbstractINTRODUCTIONThis study evaluated the performance of the Lumipulse plasma beta‐amyloid (Aβ) 42/40 and pTau181 compared to other assays to detect an abnormal amyloid‐positron emission tomography (PET).METHODSPlasma samples from cognitively unimpaired (N = 179) and MCI/AD dementia (N = 36) individuals were retrospectively evaluated. Plasma Aβ42/40 and pTau181 were measured using the Lumipulse and Simoa immunoassays. An immunoprecipitation mass spectrometry (IP‐MS) assay for plasma Aβ42/40 was also evaluated. Amyloid‐PET status was the outcome measure.RESULTSLumipulse and IP‐MS Aβ42/40 exhibited the highest diagnostic accuracy for detecting an abnormal amyloid‐PET (areas under the curve [AUCs] of 0.81 and 0.84, respectively). The Lumipulse and Simoa pTau181 assays exhibited lower performance (AUCs of 0.74 and 0.72, respectively). The Simoa Aβ42/40 assay demonstrated the lowest diagnostic accuracy (AUC 0.57). Combining Aβ42/40 and pTau181 did not significantly improve performance over Aβ42/40 alone for Lumipulse (AUC 0.83) or over pTau181 alone for Simoa (AUC 0.71)DISCUSSIONThe Lumipulse Aβ42/40 assay showed similar performance to the IP‐MS Aβ42/40 assay for detection of an abnormal amyloid‐PET; and both assays performed better than the two p‐tau181 immunoassays. The Simoa Aβ42/Aβ40 assay was the least accurate at predicting an abnormal amyloid‐PET status.Highlights Lumipulse plasma Aβ42/Aβ40 AUC for abnormal amyloid‐PET detection was 0.81. This performance was comparable to previously reported IP‐MS and higher than Simoa. Performance of Alzheimer's disease blood biomarkers varies between assays.
Importance of cerebrospinal fluid (CSF) collection protocol for the accurate diagnosis of Alzheimer's disease when using CSF biomarkers

Alzheimer's & Dementia | January 30, 2024 | Volume: 20 | Issue: 5 | Pages: 3657-3658

10.1002/alz.13721 | PMID 38288880

Patterns of CSF Biomarkers of Alzheimer’s Disease in Specialty Behavioral Neurology Practices (S2.005)

Neurology | December 6, 2023 | Volume: 98 | Issue: 18_supplement | Pages: No page available

10.1212/wnl.98.18_supplement.547

Evaluation of Siltuximab and Tocilizumab Analytical Interference on Interleukin 6 Measurements

American Journal of Clinical Pathology | November 29, 2023 | Volume: 160 | Issue: Supplement_1 | Pages: S123-S124

10.1093/ajcp/aqad150.269

Abstract Background Interleukin 6 (IL-6) plays important roles in both innate and adaptive immunity, while dysregulated persistent production of IL-6 is involved in pathological development of various diseases associated with inflammation. Targeting the IL-6 pathway has led to many innovative treatment approaches. Siltuximab and Tocilizumab are monoclonal antibodies targeting IL-6 and IL-6 receptors respectively and have been FDA-approved for treatment of Castleman disease (Siltuximab), a rare lymphoproliferative disorder characterized by hyperproduction of IL-6 with an unknown prevalence, autoimmune diseases such as rheumatoid arthritis (Tocilizumab), and both shown potential as treatment for cytokine release syndrome in hospitalized COVID-19 patients. However, the presence of siltuximab can interfere with IL-6 assays, leading to the use of C-reactive protein (CRP) as a surrogate marker to monitor its efficacy. Aim To evaluate potential Siltuximab and Tocilizumab antibody interference on IL-6 measurements in three different IL-6 protein immunoassays. Method: Serum or EDTA plasma sample pools with different IL-6 concentrations ranging from low (2.3 – 11.1 pg/mL, around the reference interval cut-off for each assay) to high (18.5 – 1142 pg/mL), above reference interval cut-off for each assay) were utilized. Various concentrations of Siltuximab or Tocilizumab were spiked into the sample pools (at 10% of total volume) to achieve final concentrations up to 600 µg/mL and up to 300 µg/mL, respectively. Sample spiked with 10% saline were used as no-drug control. Three assays were used to measure IL-6 concentration: Beckman Access IL-6 assay on UniCel DxI 800 (Beckman Coulter), V-PLEX Plus human IL-6 assay on QuickPlex SQ120 (Meso Scale Diagnostics), and a Luminex cytokine panel assay developed in house (R&D systems) with upper reference interval limits of 6.4,1.8 and 5 pg/mL respectively. Results Siltuximab interfered with the measurement of IL-6 for all three assays. A significant interference (> 20% reduction) was observed at even a very low siltuximab concentrations in all three assays (0.05 µg/mL). In the presence of 5 µg/mL or greater Siltuximab, a maximum reduction of 93%, 83%, and 40% was observed for Beckman Access, R&D Luminex assay, and V-PLEX Plus Mesoscale assay, respectively. Tocilizumab did not interfere with the measurement of IL-6 in the three assays when serum was spiked with up to 300 µg/mL of the drug. Conclusion Siltuximab falsely reduce the measured IL-6 concentration on all three immunoassays tested in this study to differing degrees, whereas Tocilizumab does not. Consider the therapeutic range of Siltuximab (84 to 332 µg/mL) for treatment of Castleman disease, and a half-life of 20.6 days, measurement of IL-6 may not be useful in Siltuximab treated patients for an extended time-period.
Postsurgical utility of copeptin for the prediction of postoperative arginine vasopressin deficiency

Journal of Neurosurgery | November 11, 2023 | Volume: 140 | Issue: 5 | Pages: 1276-1284

10.3171/2023.8.jns23418 | PMID 37948691

OBJECTIVE Arginine vasopressin deficiency (AVD) following neurosurgical procedures for pituitary disorders is common and can delay discharge. Copeptin, a stable surrogate marker of arginine vasopressin, may predict postoperative AVD. The authors’ aim was to assess the optimal postoperative sampling time and cut-point concentration of copeptin to predict the development of postsurgical AVD. METHODS Adults without preexisting AVD who were undergoing surgery for a pituitary lesion between February 2020 and April 2022 were eligible for study inclusion. Two samples were drawn from each patient postoperatively to assess the copeptin concentration using an immunofluorescent assay. Samples were denoted as "early" (within 6 hours of extubation) or "postoperative day 1" (POD1; within 10–30 hours of extubation). Patients were evaluated for the development of AVD. RESULTS One hundred ninety-two patients (54.2% female) with a median age of 54.5 years (IQR 39.8–67.0 years) were included in the study. The median copeptin concentration at both time points was significantly lower in those with AVD (transient or permanent; n = 22, 11.5%) than in those without (early: 4.9 vs 18.7 pmol/L, p < 0.001; POD1: 3.4 vs 4.9 pmol/L, p < 0.001) but did not differ in those who developed transient versus permanent AVD. The optimal copeptin cut point for the prediction of AVD was < 8.5 pmol/L for early samples (sensitivity 0.70, specificity 0.80, positive predictive value [PPV] 0.29, negative predictive value [NPV] 0.96) and < 4.3 pmol/L for POD1 samples (sensitivity 0.82, specificity 0.63, PPV 0.22, NPV 0.96). In early samples, a copeptin cutoff of 22.9 pmol/L increased the sensitivity for the detection of AVD to 95% with an NPV of 99%. The proportion of patients who had AVD was higher (60.0% vs 8.8%, p < 0.001) and the copeptin concentration lower (early: 4.3 vs 17.0 pmol/L, p < 0.001; POD1: 2.7 vs 4.9 pmol/L, p < 0.001) among those who had undergone surgery for a craniopharyngeal duct pathology versus a pituitary adenoma. Although copeptin was lower in patients with persistent Cushing’s disease than in those in remission, the difference did not reach statistical significance (early p = 0.11, POD1 p = 0.52). Furthermore, the copeptin concentration could not predict the development of syndrome of inappropriate secretion of antidiuretic hormone. Patients without AVD who had received stress dose steroids intraoperatively had lower median early copeptin (11.7 vs 19.1 pmol/L, p = 0.027). CONCLUSIONS In early postoperative copeptin samples, the optimal copeptin cut point for AVD diagnosis was < 8.5 pmol/L, and a level > 22.9 pmol/L had predicative utility in excluding AVD. Caution should be used when interpreting copeptin results, as patients administered glucocorticoids intraoperatively without AVD had lower median copeptin concentrations.