Back to Authors

Hevesi, Mario

0000-0001-6208-878X

Mayo Clinic

Department of Orthopedics and Sports Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 82

Arthroscopic Debridement and Fixation of Osteochondritis Dissecans Lesions of the Medial Femoral Condyle

Arthroscopy Techniques | July 20, 2024 | Volume: 13 | Issue: 10 | Pages: No page available

10.1016/j.eats.2024.103111 | PMID 39479035

Abstract Unstable osteochondritis dissecans lesions of the medial femoral condyle have classically been treated with open reduction and fixation under direct visualization through an open arthrotomy. Given the value of avoiding open arthrotomies, we present an arthroscopic approach for lesion elevation, debridement, and fixation. The lesion is first elevated using an arthroscopic elevator, leaving a laterally based osseous hinge. Once elevated, fibrous debris is debrided from the base of the lesion. Subsequently, the fragment is reduced, and percutaneous transpatellar instrumentation is used for fixation. The use of this technique allows for excellent mobilization, debridement, and fixation of the osteochondritis dissecans lesion while minimizing violation of periarticular soft tissues. Technique Video video See video under supplementary data.
Simulated Cam Morphology of the Hip Changes Sacroiliac Motion During Hip Motion and Loading in a Cadaveric Model

Arthroscopy, Sports Medicine, and Rehabilitation | July 17, 2024 | Volume: 6 | Issue: 6 | Pages: No page available

10.1016/j.asmr.2024.100977 | PMID 39776497

Purpose To determine the relationship between cam morphology of the hip and ipsilateral sacroiliac motion compared to the native hip in a cadaveric model. Methods A simulated cam state was created using a 3‐dimensional printed cam secured to the head‐neck junction of 5 cadaveric hips. Hips were studied using a computed tomography–based optic metrology system and a 6 degree‐of‐freedom robot to exert an internal rotation torque at 3 different torque levels (6 N‐m, 12 N‐m, 18 N‐m). Outcomes included translational and rotational movement about 3 axes and composite (total) translational motion at the ipsilateral sacroiliac (SI) joint. Statistical analysis included a linear mixed model regression with repeated measures. Results The presence of a simulated cam was associated with medial motion in the coronal plane ( P = .03) and posterior motion in the sagittal plane ( P < .01) but not composite motion ( P = .37). Motion in the axial plane was in an inferior direction ( P = .08). Cam morphology significantly changed rotation in the sagittal plane ( P < .01) but not in the coronal ( P = .63) or axial plane ( P = .18). Composite motion was related to the amount of torque applied to the hip ( P < .01). The amount of torque applied to the hip was related to rotation in the coronal plane ( P < .01), axial plane ( P < .01), and sagittal plane ( P < .01) with increased effects as torque increased. Torque was not associated with translation movement in any of the anatomic planes. Conclusions The presence of simulated cam morphology is associated with motion in a more medial, inferior, and posterior direction at the ipsilateral SI joint relative to a native state. Increasing torque affects the magnitude of translation, but not its direction, which in this study is primarily influenced by cam morphology. Clinical Relevance This biomechanical connection between cam‐type femoroacetabular impingement syndrome and the ipsilateral SI joint provides insight into SI joint dysfunction in patients with femoroacetabular impingement syndrome.
Fatty Infiltration, Tear Size, and Retraction Size Are Significant Risk Factors for Retear After Arthroscopic Rotator Cuff Repair: A Systematic Review

Arthroscopy | July 8, 2024 | Volume: 41 | Issue: 5 | Pages: 1649

10.1016/j.arthro.2024.06.040 | PMID 38986851

Purpose To assess the consistency and quality of risk factor reporting for rotator cuff repair (RCR) retear and identify risk factors most frequently associated with retear. Methods A systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta‐analyses (PRISMA) guidelines. Of the initial 3,158 studies, a total of 31 met the following inclusion criteria: (1) clinical studies regarding RCR failure, (2) arthroscopic procedures involving RCR, (3) reporting of clinical outcomes, (4) publication within the past 5 years, and (5) studies investigating preoperative risk factors for retear. After full‐text review, 18 risk factors were analyzed. Results The most consistently significant risk factors were acromiohumeral distance (80%), critical shoulder angle (67%), tear size (63%), anterior‐posterior dimension (60%), fatty infiltration (FI) (58%), and retraction size (56%). FI was analyzed using different methods among studies, with 63% finding significant results and 50% of all studies performing ordinal analysis. Tear size was inconsistently analyzed quantitatively or qualitatively, with 58% of studies finding significant results and 63% of all studies performing quantitative analysis. Risk factors consistently found to be nonsignificant included age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. Conclusions Tear size, FI, and retraction size were found to be significant risk factors in most of the included studies evaluating rotator cuff retear. Risk factors less likely reported as predictive included repair technique, age, sex, diabetes mellitus, symptom duration, hand dominance, repair technique, smoking, and body mass index. Risk factors that require further investigation include critical shoulder angle, acromiohumeral distance, and anterior‐posterior tear dimension. Level of Evidence Level III, systematic review of Level III‐IV studies.
Arthroscopic Pincer Resection Utilizing an Outside‐In Approach for Intra‐articular Access

Arthroscopy Techniques | June 14, 2024 | Volume: 13 | Issue: 10 | Pages: No page available

10.1016/j.eats.2024.103074 | PMID 39479040

Abstract In the standard approach to hip arthroscopy, access to the joint is achieved using fluoroscopic guidance to enter the central compartment of the hip using the Seldinger technique, penetrating the capsule with a needle and subsequently cannulating and obtaining direct visualization of the joint. In such a way, arthroscopists then proceed with accessory portal creation and capsulotomy, as desired, under direct intra‐articular visualization. In cases with severe pincer morphology or coxa profunda, it may not be possible to safely access the central compartment under fluoroscopic guidance due to significant lateral overcoverage of the femoral head. We present an outside‐in arthroscopic approach for accessing the hip joint in such patients, allowing for safe visualization, osseous pincer resection, and improved central compartment access while minimizing the risk to cartilage and labral tissue. Technique Video video See video under supplementary data.
Osteochondral Allograft Transplantation for the Treatment of an Acetabular Defect

JBJS Case Connector | May 31, 2024 | Volume: 14 | Issue: 2 | Pages: No page available

10.2106/jbjs.cc.24.00033 | PMID 38820204

Case: A 20-year-old woman presented with a unipolar, 1.8 × 1.8-cm osteochondral defect of the left acetabulum. Osteochondral allograft transplantation was performed using a medial tibial plateau allograft resulting in excellent clinical outcomes across 4 different outcome scores and maintenance of the joint space at 4.3 years postoperatively. Conclusion: Although previous literature has demonstrated long-term clinical success of osteochondral allograft transplantation in knee, excellent clinical outcomes can also be obtained in the hip. Thus, osteochondral allograft transplantation may be a viable treatment option for adolescents and young adults with concomitant cartilage and subchondral bone hip defects.
Posterolateral Acetabular Labral Repair: Drilling Using a Percutaneous Posterolateral Portal

Arthroscopy Techniques | April 16, 2024 | Volume: 13 | Issue: 7 | Pages: No page available

10.1016/j.eats.2024.102994 | PMID 39100270

Abstract Acetabular labral tears are commonly diagnosed in patients with hip or groin pain, most of which occur anterosuperiorly. In some cases, operative intervention in the form of arthroscopic labral repair may be necessary to restore labral function. Posterolateral tears can be technically challenging when using traditional modified anterior portal and anterolateral (AL) portal access owing to a suboptimal drill trajectory. In this article, we describe the establishment of a posterolateral (PL) portal 1 to 2 cm posterior to the tip of the greater trochanter, mirroring the distal‐to‐proximal trajectory of the AL portal and entering the capsulotomy at the 10‐o'clock position. This method highlights that the PL portal is used for drilling and anchor placement, whereas the remaining work is performed through the AL portal. This avoids the use of any shavers or burrs in the PL portal near important neurovascular structures, including the sciatic nerve. Addressing posterolateral labral tears in the 9‐ to 11‐o'clock position using a PL portal can enhance labral fixation, thereby mitigating the risk of suboptimal repairs that can negatively impact postoperative outcomes. Technique Video video See video under supplementary data.
iPhone‐Based Cartilage Topography Scanning Yields Similar Results to Computed Tomography Scanning

Arthroscopy, Sports Medicine, and Rehabilitation | April 9, 2024 | Volume: 6 | Issue: 4 | Pages: No page available

10.1016/j.asmr.2024.100936 | PMID 39421352

Purpose To investigate the feasibility and accuracy of 3‐dimensional (3D) iPhone scans using commercially available applications compared with computed tomography (CT) for mapping chondral surface topography of the knee. Methods Ten cadaveric dysplastic trochleae, 16 patellae, and 24 distal femoral condyles (DFCs) underwent CT scans and 3D scans using 3 separate optical scanning applications on an iPhone X. The 3D surface models were compared by measuring surface‐to‐surface least distance distribution of overlapped models using a validated 3D‐3D registration volume merge method. The absolute least mean square distances for the iPhone‐generated models from each scanning application were calculated in comparison to CT models using a point‐to‐surface distance algorithm allowing regional “inside/outside” measurement of the absolute distance between models. Results Only 1 of the 3 scanning applications created models usable for quantitative analysis. Overall, there was a median absolute least mean square distance between the usable model and CT‐generated models of 0.18 mm. The trochlea group had a significantly lower median absolute least mean square distance compared with the DFC group (0.14 mm [interquartile range, 0.13‐0.17] vs 0.19 mm [0.17‐0.25], P = .002). iPhone models were smaller compared with CT models (negative signed distances) for all trochleae, 83% of DFCs, and 69% of patellae. Conclusions In this study, we found minimal differences between a 3D iPhone scanning application and conventional CT scanning when analyzing surface topography. Clinical Relevance Emerging 3D iPhone scanning technology can create accurate, inexpensive, real‐time 3D models of the intended target. Surface topography evaluation may be useful in graft selection during surgical procedures such as osteochondral allograft transplantation.
Arthroscopic Fractional Lengthening After Total Hip Arthroplasty Results in Improved Patient‐Reported Outcomes and Low Rates of Revision Total Hip Arthroplasty

Arthroscopy, Sports Medicine, and Rehabilitation | March 26, 2024 | Volume: 6 | Issue: 3 | Pages: No page available

10.1016/j.asmr.2024.100930 | PMID 39006778

Purpose To report the clinical outcomes and reoperation rates of arthroscopic and endoscopic iliopsoas release at short‐term follow‐up after ipsilateral total hip arthroplasty (THA) at 2 separate medical institutions and to evaluate whether demographic and radiographic parameters are associated with postoperative patient‐reported outcomes (PROs). Methods Patients with iliopsoas tendinitis in the setting of prior THA who underwent arthroscopic iliopsoas fractional lengthening from 1988 to 2023 at 2 academic institutions were reviewed. Patients were included if they had 12 months of follow‐up and underwent evaluation of preoperative anterior acetabular component overhang, surgery satisfaction, postoperative subjective hip flexion strength and anterior groin pain improvement, modified Harris Hip Score, Single Assessment Numeric Evaluation score, Tegner activity scale score, visual analog scale (VAS) score, and revision hip arthroplasty. Results Sixty hips in 58 patients (19 male and 39 female patients) were followed up for a mean of 39.3 months (range, 12.0‐105.9 months) postoperatively. Of the patients, 77% reported feeling “much better” or “slightly better,” 75% reported improved anterior groin pain, and 60% reported improved subjective hip flexion strength. The surgery satisfaction rating was 7.2 ± 3.3 (scale of 0 to 10). The mean postoperative modified Harris Hip Score, VAS score for pain at rest, VAS score for pain with use, and Single Assessment Numeric Evaluation score were 73.9 ± 19.4, 1.3 ± 2.4, 3.8 ± 2.9, and 71.9 ± 21.9, respectively. Preoperative anterior acetabular component overhang was 3.3 ± 6.5 mm and did not significantly correlate with postoperative PROs ( P ≥ .45). The Tegner score improved from 2.5 ± 1.7 preoperatively to 2.9 ± 1.4 postoperatively ( P = .0253). Three patients underwent revision arthroplasty at a mean of 25.3 months (range, 11.6‐40.4 months) postoperatively, with an acetabular component revision rate of 3.3%. Conclusions Satisfactory outcomes and low revision arthroplasty rates were observed in patients undergoing arthroscopic iliopsoas lengthening after THA. There was no statistically significant relation between anterior acetabular component overhang and final PROs. Level of Evidence Level IV, therapeutic case series.
Arthroscopic Hip Capsular Reconstruction: A Step‐by‐Step Guide With Rectus Overlay

Arthroscopy Techniques | March 23, 2024 | Volume: 13 | Issue: 6 | Pages: No page available

10.1016/j.eats.2024.102982 | PMID 39036399

Abstract The hip capsule is the primary stabilizer of the hip joint. At the time of hip arthroscopy, the capsule is disrupted to obtain intra‐articular access and proper joint visualization. With the number of patients undergoing primary and revision hip arthroscopy continuing to increase, it is not uncommon for surgeons to encounter patients with iatrogenic capsular deficiency from prior hip arthroscopy. In cases where substantial capsular defects beyond the scope of capsular repair are visualized, reconstruction may be required to obtain satisfactory closure and restore hip stability. We present a step‐by‐step workflow for efficient hip capsular reconstruction with rectus overlay while allowing for facile incorporation of other revision procedures such as labral repair and femoral osteochondroplasty. Technique Video video See video under supplementary data.
Inside‐Out Anchor Placement: A Technique to Instrument Far Medial Anchors in Acetabular Labral Repair

Arthroscopy Techniques | February 24, 2024 | Volume: 13 | Issue: 5 | Pages: No page available

10.1016/j.eats.2024.102949 | PMID 38835447

Abstract Labral tears most commonly occur anteriorly between the 12‐ and 3‐o'clock positions, with the 12‐o'clock position denoted as superior and the 3‐o'clock position denoted as anterior. When approaching the 3‐o'clock position and beyond, suture anchor placement becomes difficult given the challenging arthroscopic trajectory and an overall thin anterior rim of cortical bone for anchor purchase, resulting in a narrow angle of safe drilling. The purpose of this technical note is to present a safe and reproducible method of suture anchor placement during acetabular labral repair approaching the 3‐ and 4‐o'clock positions, with the 12‐o'clock position representing the superior anatomic location and the 3‐o'clock position representing the anterior anatomic location regardless of hip laterality. We use an inside‐out anchor placement technique to place far medial anchors, which differs from the conventional techniques (e.g., outside‐in technique) in which anchor placement is performed along the external margin of the acetabular labrum. Technique Video video See video under supplementary data.