Back to Authors

Topilsky, Yan

0000-0002-2269-802X

Mayo Clinic

Division of Cardiology, Tel Aviv Medical Center, Faculty of Medicine, Tel Aviv University, 6 Weizmann Street, Tel Aviv 6423906, Israel.

Citations 23

Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves

Circulation | January 22, 2018 | Volume: 137 | Issue: 4 | Pages: 388-399

10.1161/circulationaha.117.030729 | PMID 29358344

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
Atrial Fibrillation Should Guide Prophylactic Tricuspid Procedures During Left Ventricular Assist Device Implantation

ASAIO Journal | October 31, 2017 | Volume: 64 | Issue: 5 | Pages: 586-593

10.1097/mat.0000000000000698 | PMID 29088022

Atrial fibrillation (AF) and tricuspid regurgitation (TR) are common in patients undergoing left ventricular assist device (LVAD) implantation. TR progression is associated with the presence of AF, and questions remain as to who benefits from tricuspid valve procedures (TVPs). We examined the impact of preoperative AF on TR progression after LVAD implantation. From February 2007 to May 2014, 250 patients underwent LVAD implantation at our institution. Patients with concomitant TVP were excluded from this analysis (113 patients). The indication for LVAD was destination therapy in 80 patients (58%) and the etiology of heart failure was ischemic in 73 (53%). Follow-up was available in all early survivors for a total of 393 patient-years of support. Of the 137 non-TVP patients, 52 (38%) had AF preoperatively. Observed overall survival at 1, 3, and 5 years was 82%, 67%, and 55%, respectively. Median grade of TR increased from 2 preoperatively to 3 (p = 0.04) in the AF group and 2.2 (p = 0.75) in the non-AF group at 5 years of follow-up. We also observed a significant difference in the degree of TR between groups at 3 months (p = 0.03) and 12 months (p = 0.01) postimplantation, and a trend toward significance at 18 (p = 0.06) and 24 (p = 0.07) months. The presence of AF is associated with early progression of TR after LVAD implantation. Addition of concomitant TVP in patients with preoperative AF may be considered in patients with less than severe TR. The impact of these findings on right ventricular failure/remodeling remains to be evaluated.
Early Gains in Renal Function Following Implantation of HeartMate II Left Ventricular Assist Devices May Not Persist to One Year

ASAIO Journal | January 21, 2017 | Volume: 63 | Issue: 4 | Pages: 401-407

10.1097/mat.0000000000000511 | PMID 28114196

Renal function improves early after left ventricular assist device (LVAD) implantation but later decline has been observed. We sought to determine the occurrence and evaluate possible causes for this decline. In 62 consecutive patients with HeartMateII LVAD with available calculated glomerular filtration rate (GFR, ml/min/1.73 m2) 1 year after implant, GFR was assessed repeatedly and possible predictors for decline from 3 to 12 months were investigated. Post-mortem renal specimens for patients supported with an LVAD were evaluated. GFR 54.5 ± 19.5 at admission increased to 66.4 ± 22.3 preoperatively and to 79.2 ± 30.1 ~1 month after implantation. Subsequently at ~3 months GFR declined to 74.7 ± 25.4, at ~6 months to 68.8 ± 23.1, and ~1 year after implant to 63.9 ± 17.7. Glomerular filtration rate at 1 year was significantly lower (p < 0.0001, p < 0.0001, p = 0.005) than GFR 1, 3, and 6 months after implant. Early rise in GFR after surgery was not associated with late decline. Shorter bypass time (β = −0.09, p = 0.048) and higher albumin 3 months after LVAD (β = 14.4, p = 0.025) were significantly associated with less later decline in GFR. Arteriosclerosis was identified in autopsy renal specimens. In conclusion, early gains in renal function after LVAD implant are not sustained in many patients. Patient, device, and operative factors may influence long-term renal function in these patients.
Real‐Time 3‐Dimensional Dynamics of Functional Mitral Regurgitation: A Prospective Quantitative and Mechanistic Study

Journal of the American Heart Association | June 1, 2013 | Volume: 2 | Issue: 3 | Pages: No page available

10.1161/jaha.113.000039 | PMID 23727698

Background Three‐dimensional transthoracic echocardiography (3D‐ TTE ) with dedicated software permits quantification of mitral annulus dynamics and papillary muscle motion throughout the cardiac cycle. Methods and Results Mitral apparatus 3D‐ TTE was acquired in controls (n=42), patients with left ventricle dysfunction and functional mitral regurgitation ( LVD ‐ FMR ; n=43) or without FMR ( LVD ‐no MR , n=35). Annulus in both normal and LVD ‐no MR subjects displayed saddle shape accentuation in early‐systole (ratio of height to intercommissural diameter, 10.6±3.7 to 13.5±4.0 in normal and 9.1±4.3 to 12.6±3.6 in LVD ‐no MR ; P <0.001 for diastole to early‐systole motion, P = NS between those groups). In contrast, saddle shape was unchanged from diastole in FMR patients (10.0±6.4 to 8.0±5.2; P = NS , P <0.05 compared to both other groups). Papillary tips moved symmetrically towards to the midanterior annulus in control and LVD ‐no MR subjects, maintaining constant ratio of the distances between both tips to midannulus (Pt AR ) throughout systole. In LVD ‐ FMR patients midsystolic posterior papillary tip to anterior annulus distance was increased, resulting in higher Pt AR ( P =0.05 compared to both other groups). Mechanisms of early‐ and midsystolic FMR differed between different etiologies of LV dysfunction. In patients with anterior MI and global dysfunction annular function and dilatation were the dominant parameters, while papillary muscle motion was the predominant determinant of FMR in patients with inferior MI . Conclusions Inadequate early‐systolic annular contraction and saddle‐shape accentuation in patients with impaired LV contribute to early–mitral incompetency. Asymmetric papillary tip movement towards the midanterior annulus is a major determinant of mid‐ and late‐systolic functional mitral regurgitation.
Right Ventricular Systolic Function in Organic Mitral Regurgitation

Circulation | March 14, 2013 | Volume: 127 | Issue: 15 | Pages: 1597-1608

10.1161/circulationaha.112.000999 | PMID 23487435

Background— To assess the prevalence, determinants, and prognosis value of right ventricular (RV) ejection fraction (EF) impairment in organic mitral regurgitation. Methods and Results— Two hundred eight patients (62±12 years, 138 males) with chronic organic mitral regurgitation referred to surgery underwent an echocardiography and biventricular radionuclide angiography with regional function assessment. Mean RV EF was 40.4±10.2%, ranging from 10% to 65%. RV EF was severely impaired (≤35%) in 63 patients (30%), and biventricular impairment (left ventricular EF<60% and RV EF≤35%) was found in 34 patients (16%). Pathophysiologic correlates of RV EF were left ventricular septal function (β=0.42, P <0.0001), left ventricular end-diastolic diameter index (β=−0.22, P =0.002), and pulmonary artery systolic pressure (β=−0.14, P =0.047). Mitral effective regurgitant orifice size (n=84) influenced RV EF (β=−0.28, P =0.012). In 68 patients examined after surgery, RV EF increased strongly (27.5±4.3–37.9±7.3, P <0.0001) in patients with depressed RV EF, whereas it did not change in others ( P =0.91). RV EF ≤35% impaired 10-year cardiovascular survival (71.6±8.4% versus 89.8±3.7%, P =0.037). Biventricular impairment dramatically reduced 10-year cardiovascular survival (51.9±15.3% versus 90.3±3.2%, P <0.0001; hazard ratio, 5.2; P <0.0001) even after adjustment for known predictors (hazard ratio, 4.6; P =0.004). Biventricular impairment reduced also 10-year overall survival (34.8±13.0% versus 72.6±4.5%, P =0.003; hazard ratio, 2.5; P =0.005) even after adjustment for known predictors ( P =0.048). Conclusions— In patients with organic mitral regurgitation referred to surgery, RV function impairment is frequent (30%) and depends weakly on pulmonary artery systolic pressure but mainly on left ventricular remodeling and septal function. RV function is a predictor of postoperative cardiovascular survival, whereas biventricular impairment is a powerful predictor of both cardiovascular and overall survival.
Mitral Valve Prolapse With Mid-Late Systolic Mitral Regurgitation

Circulation | March 5, 2012 | Volume: 125 | Issue: 13 | Pages: 1643-1651

10.1161/circulationaha.111.055111 | PMID 22388325

Background— Mitral regurgitation (MR) of mitral valve prolapse predominates in late systole but may be holosystolic or purely mid-late systolic, but the impact of MR timing on MR left ventricular and left atrial consequences and outcome is unknown. Whether effective regurgitant orifice (ERO) by the flow convergence method is similarly linked to outcome in mid-late systolic MR and holosystolic MR is uncertain. Methods and Results— We comprehensively and prospectively quantified MR in 111 patients with mitral valve prolapse and mid-late systolic MR and matched them to 90 patients with mitral valve prolapse and holosystolic MR for age, gender, atrial fibrillation, ejection fraction, and ERO (flow convergence). Mid-late systolic MR versus holosystolic MR groups were well matched, including for comorbidity, blood pressure, and heart rate (all P >0.10). Mid-late systolic MR versus holosystolic MR caused similar color jet area, midsystolic regurgitant flow, and peak velocity ( P >0.40). Despite identical ERO (0.25±0.15 versus 0.25±0.15 cm 2 ; P =0.53), the shorter duration of mid-late systolic MR (233±56 versus 426±50 ms; P <0.0001) yielded lower regurgitant volume (24.8±13.4 versus 48.6±25.6 mL; P <0.0001). MR consequences, systolic pulmonary pressure, and left ventricular and left atrial volume index (all P <0.001) were more benign in mid-late systolic MR versus holosystolic MR. Under medical management, fewer cardiac events (5 years: 15.8±4.6% versus 40.4±6.1%; P <0.0001) occurred in mid-late systolic MR versus holosystolic MR, requiring less mitral surgery. Multivariable analysis confirmed the independent association of mid-late systolic MR with benign consequences and outcomes (all P <0.01). Absolute ERO was not linked to outcome, in contrast to regurgitant volume. Conclusions— MR of mitral valve prolapse that is purely mid-late systolic causes more benign consequences and outcomes than holosystolic MR. Assessment may be misleading because jet area and ERO by flow convergence appear similar to those of holosystolic MR. However, shorter MR yields lower regurgitant volume, consequences, and benign outcomes. Instantaneous ERO by flow convergence should be interpreted in context, and in mid-late systolic MR, regurgitant volume provides information more reflective of MR severity. Therefore, for clinical management and surgical referral, clinicians should carefully take into account the timing and consequences of MR.
Sirolimus as Primary Immunosuppression Attenuates Allograft Vasculopathy With Improved Late Survival and Decreased Cardiac Events After Cardiac Transplantation

Circulation | December 30, 2011 | Volume: 125 | Issue: 5 | Pages: 708-720

10.1161/circulationaha.111.040360 | PMID 22207715

Background— We retrospectively analyzed the potential of sirolimus as a primary immunosuppressant in the long-term attenuation of cardiac allograft vasculopathy progression and the effects on cardiac-related morbidity and mortality. Methods and Results— Forty-five cardiac transplant recipients were converted to sirolimus 1.2 years (0.2, 4.0) after transplantation with complete calcineurin inhibitor withdrawal. Fifty-eight control subjects 2.0 years (0.2, 6.5 years) from transplantation were maintained on calcineurin inhibitors. Age, sex, ejection fraction, and time from transplantation to baseline intravascular ultrasound study were not different ( P >0.2 for all) between the groups; neither were secondary immunosuppressants and use of steroids. Three-dimensional intravascular ultrasound studies were performed at baseline and 3.1 years (1.3, 4.6 years) later. Plaque index progression (plaque volume/vessel volume) was attenuated in the sirolimus group (0.7±10.5% versus 9.3±10.8%; P =0.0003) owing to reduced plaque volume in patients converted to sirolimus early (<2 years) after transplantation ( P =0.05) and improved positive vascular remodeling ( P =0.01) in patients analyzed late (>2 years) after transplantation. Outcome analysis in 160 consecutive patients maintained on 1 therapy was performed regardless of performance of intravascular ultrasound examinations. Five-year survival was improved with sirolimus (97.4±1.8% versus 81.8±4.9%; P =0.006), as was freedom from cardiac-related events (93.6±3.2% versus 76.9±5.5%; P =0.002). Conclusions— Substituting calcineurin inhibitor with sirolimus as primary immunosuppressant attenuates long-term cardiac allograft vasculopathy progression and may improve long-term allograft survival owing to favorable coronary remodeling. Because of the lack of randomization and retrospective nature of our analysis, the differences in outcome should be interpreted cautiously, and prospective clinical trials are required.
Echocardiographic Variables After Left Ventricular Assist Device Implantation Associated With Adverse Outcome

Circulation: Cardiovascular Imaging | September 22, 2011 | Volume: 4 | Issue: 6 | Pages: 648-661

10.1161/circimaging.111.965335 | PMID 21940507

Background— Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. Methods and Results— We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16–1.48]; P <0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22–18]; P =0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48–0.95]; P =0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21–13.3]; P =0.01). Conclusions— Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.
Preoperative Factors Associated With Adverse Outcome After Tricuspid Valve Replacement

Circulation | April 26, 2011 | Volume: 123 | Issue: 18 | Pages: 1929-1939

10.1161/circulationaha.110.991018 | PMID 21518976

Background— Preoperative factors associated with increased mortality and worse outcome after tricuspid valve replacement in patients with severe tricuspid regurgitation are poorly understood. Methods and Results— We retrospectively analyzed 189 patients (37% men; age, 67.5±11.3 years) who underwent tricuspid valve replacement for severe tricuspid regurgitation. Operative mortality rate was 10%, and was associated with intra-aortic balloon pump (odds ratio, 3.2; 95% confidence interval, 1.9 to 5.6; P <0.0001) or the presence of severe symptoms (New York Heart Association class IV relative to classes II and/or III) at the time of surgery (1.7; 95% confidence interval, 1.05 to 2.8; P =0.02). At the end of follow-up (29.3±27.1 months), 70 patients (37%) died, 6 (3%) needed tricuspid reoperation, and 41 (21.7%) were readmitted for heart failure. Seventy-eight patients (41.3%) were free from cardiovascular events (death, tricuspid reoperation, or heart failure admissions). The only echocardiographic parameter independently associated with adverse outcomes was a decrease in the right index of myocardial performance ratio. All-cause mortality was independently associated with a higher Charlson index (hazard ratio, 1.18; 95% confidence interval, 1.01 to 1.36; P =0.03), shorter right index of myocardial performance ratio (0.91; 95% confidence interval, 0.87 to 0.96; P =0.005), and preoperative New York Heart Association IV class (1.71; 95% confidence interval, 1.3 to 2.2; P <0.0001). In 68 patients with isolated tricuspid valve replacement, the associations between short right index of myocardial performance ratio, high Charlson index, New York Heart Association class IV, and increased mortality remained significant. Conclusions— Tricuspid valve replacement for severe tricuspid regurgitation can be performed with an acceptable operative mortality if patients undergo surgery before the onset of advanced heart failure symptoms. Late mortality is associated with a high preoperative Charlson index, short right index of myocardial performance ratio, and advanced New York Heart Association class.
Left Ventricular Assist Device Therapy in Patients With Restrictive and Hypertrophic Cardiomyopathy

Circulation: Heart Failure | February 9, 2011 | Volume: 4 | Issue: 3 | Pages: 266-275

10.1161/circheartfailure.110.959288 | PMID 21303989

Background— Left ventricular assist device (LVAD) is being increasingly used in patients with end-stage dilated and ischemic cardiomyopathy. There have been no clinical trials addressing the use of LVAD therapy in patients with end-stage heart failure caused by restrictive (RCM) or hypertrophic cardiomyopathy (HCM). The purpose of this study was therefore to analyze the outcome of LVAD therapy in these patients. Methods and Results— Eighty-three patients received continuous axial flow LVAD (Heart mate II, Thoratec, Pleasanton, CA) from February 2007 to May 2010 at our institution. We analyzed the baseline characteristics and surgical and long-term impact of LVAD therapy in 8 patients with RCM or HCM and compared their outcomes with the 75 patients with dilated and ischemic cardiomyopathy. Compared with patients with ischemic or dilated cardiomyopathy, patients with RCM and HCM have significantly smaller left ventricular end-diastolic dimensions (52.5±6 mm versus 68.6±8 mm; P <0.0001) and increased thickness of septal (16 [12, 19] mm versus 10[8.5, 11] mm, P =0.0003) and higher left ventricular ejection fraction (21 [20, 36]% versus 17 [15, 22]%; P =0.0009). We found no difference in early mortality (12.5% versus 9.3%, P =0.57) or length of hospital stay (11 [8, 45] days versus 18.5 [12.2, 27.7] days; P =0.51) between the 2 groups. The right atrial pressure was higher (18 [15, 20] mm Hg versus 12 [9, 15] mm Hg, P =0.03), and pump flow was lower (4.3 [3.8, 4.5] L versus 5.2 [4.7, 5.5] L, P =0.001) after LVAD implantation in patients with RCM and HCM. Central venous catheter related infections were more common in patients with RCM and HCM (87.5% versus 44.5%, P =0.006). There was no difference in the total number of blood units transfused. Median (min, max) follow-up duration after LVAD implantation was 166 [1, 1044] days. The 1-year actuarial survival rate was not different between the 2 groups (87.5% [95% confidence interval, 52.9% to 97.8%] versus 73.2 [95% confidence interval, 60% to 85%]; P =0.77). Conclusions— Our preliminary data show that patients with end-stage heart failure caused by RCM or HCM may benefit from continuous axial flow LVAD therapy. This small study suggests that mortality is comparable with those patients who have dilated or ischemic cardiomyopathy, but right heart failure, prolonged inotropic use, and central venous catheter infections are more common in patients with RCM and HCM who were treated with LVAD. Because of the small numbers the differences should be interpreted cautiously, and prospective clinical trials would be required to recommend this therapy for these patients as bridge to transplantation or destination treatment.