Back to Authors

Kowlgi, Narayan G

0000-0002-0913-3497

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 25

What Is the Mechanism of Atrial Fibrillation Initiation?

Circulation | December 26, 2024 | Volume: 151 | Issue: 1 | Pages: 120-122

10.1161/circulationaha.124.072920 | PMID 39723981

Catheter ablation of atrial fibrillation in patients with and without hypertrophic cardiomyopathy: systematic review and meta-analysis

Europace | August 18, 2023 | Volume: 25 | Issue: 9 | Pages: No page available

10.1093/europace/euad256 | PMID 37595138

Abstract Background Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). There is limited data regarding the outcomes of AF catheter ablation in HCM patients. In this study, we aimed to synthesize all available evidence on the effectiveness of ablation of AF in patients with HCM compared to those without HCM. Methods and results We systematically reviewed bibliographic databases to identify studies published through February 2023. We included cohort studies with available quantitative information on rates of recurrent atrial arrhythmias, anti-arrhythmic drug (AAD) therapy, and repeat ablation procedures after initial AF ablation in patients with vs without HCM. Estimates were combined using random-effects meta-analysis models and reported as risk ratios (RR) and 95% confidence intervals (CI). Eight studies were included in quantitative synthesis (262 HCM and 642 non-HCM patients). During median follow-up 13–54 months across studies, AF recurrence rates ranged from 13.3% to 92.9% in HCM and 7.6% to 58.8% in non-HCM patients. The pooled RR for recurrent atrial arrhythmia after the first AF ablation in HCM patients compared to non-HCM controls was 1.498 (95% CI = 1.305–1.720; P < 0.001). During follow-up, HCM patients more often required AAD therapy (RR = 2.844; 95% CI = 1.713–4.856; P < 0.001) and repeat AF ablation (RR = 1.544; 95% CI = 1.070–2.228; P = 0.02). The pooled RR for recurrent atrial arrhythmias after the last AF ablation was higher in patients with HCM than those without HCM (RR = 1.607; 95% CI = 1.235–2.090; P < 0.001). Conclusions Compared to non-HCM patients, those with HCM had higher rates of recurrent atrial arrhythmias, AAD use, and need for repeat AF ablation after initial ablation of AF.
Bezold–Jarisch reflex mediated syncope in pulmonary arterial hypertension: An illustrative case series

Pulmonary Circulation | October 11, 2022 | Volume: 12 | Issue: 4 | Pages: No page available

10.1002/pul2.12147 | PMID 36325510

AbstractWe present a novel description of Bezold–Jarisch Reflex (BJR) during cardiopulmonary exercise testing (CPET) in three young female patients with Group 1 pulmonary arterial hypertension (PAH). These three cases presented within 26 months, representing only 0.8% of 11,387 tests on patients with PAH undergoing CPET during this time frame.
Cardiac resynchronization therapy response in cardiac sarcoidosis

Journal of Cardiovascular Electrophysiology | July 23, 2022 | Volume: 33 | Issue: 9 | Pages: 2072-2080

10.1111/jce.15631 | PMID 35870183

AbstractIntroductionCardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS.ObjectiveTo determine if CRT improved cardiac remodeling in patients with CS.MethodsWe retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed.ResultsOur cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT‐D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT‐P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end‐diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow‐up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died.ConclusionsOur findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Safety of catheter ablation in obese patients: Less complicated than you think

Journal of Cardiovascular Electrophysiology | February 4, 2022 | Volume: 33 | Issue: 4 | Pages: 664-666

10.1111/jce.15394 | PMID 35118744

Catheter ablation versus medical therapy for atrial fibrillation: Penny‐wise Pound‐foolish

Journal of Cardiovascular Electrophysiology | December 12, 2021 | Volume: 33 | Issue: 2 | Pages: 176-177

10.1111/jce.15316 | PMID 34897873

AbstractCatheter ablation for atrial fibrillation has emerged as a mainstay for the management of atrial fibrillation. It has been shown to be clinically effective and cost‐effective in multiple trials.
Catheter Ablation Versus Medical Therapy for Atrial Fibrillation - Penny wise Pound Foolish !

No container title available | December 4, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163864894.46936919/v1

Catheter ablation for atrial fibrillation has emerged as a main stay for management of atrial fibrillation. It has been shown to be clinically effective and cost effective in multiple trials .
A Real-world Experience of Atrioventricular Synchronous Pacing with Leadless Ventricular Pacemakers

No container title available | November 16, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.163711930.05423871/v1

Aims: The MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer-based atrial sensing. Data regarding the real-world experience with this novel system are currently lacking. We sought to characterize patients undergoing MicraTM -AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony. Methods: In this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM -AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow-up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous-ventricular pacing (AsVP) ≥70%. Results: Fifty-six percent of patients achieved AsVP ≥70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure and pulmonary hypertension. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were persistent atrial arrhythmias, small A4-wave amplitude, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow-up. Conclusion: With the increasing popularity of leadless PM, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM -AV devices.
Efficacy of intentional permanent atrial pacing in the long‐term management of congenital long QT syndrome

Journal of Cardiovascular Electrophysiology | January 29, 2021 | Volume: 32 | Issue: 3 | Pages: 782-789

10.1111/jce.14920 | PMID 33512040

AbstractBackgroundUnfortunately, some patients with long QT syndrome (LQTS) experience breakthrough cardiac events (BCEs) despite maximal therapy. Small studies have shown that refractory LQTS cases may benefit from intentional permanent atrial pacing (IPAP). As such, we sought to determine the genotype‐specific utilization and efficacy of IPAP in a single‐center LQTS registry.Methods and ResultsIn this retrospective study, electronic medical records from 1065 patients diagnosed with LQTS were used to identify individuals that received IPAP. Pre‐ and post‐IPAP heart rate, heart rate‐corrected QT (QTc) values, annual BCE rate, and IPAP‐related complications were compared between genotypes. BCEs were defined as LQTS‐associated syncope/seizures, sustained ventricular arrhythmia (VA)‐terminating ICD therapies, and sudden cardiac arrest/death.Overall, 52 out of 1065 LQTS patients received adjunctive IPAP therapy (77% female; median age 18.5 [interquartile range, 1–35.5] years; 73% with prior VA). Over an average IPAP follow‐up of 121 ± 82 months, the average heart rate increased from 65.8 ± 20.4 bpm to 78.9 ± 17.1 bpm; (p < .01) and the average QTc decreased from 533.4 ± 66.6 to 488.3 ± 52.4 ms; (p < .01). The mean BCE rate dropped from 0.88 to 0.19 per patient‐year (p = .01), driven by a marked decrease in the LQT2 cohort (1.01 BCE/year to 0.02 BCE/year; p = .003). No serious IPAP‐related complications were observed.ConclusionIn high‐risk LQTS patients, namely those with recalcitrant LQT2, IPAP appears to be a safe and efficacious adjunct therapy. The beneficial effects of IPAP may stem from attenuating the QTc and circumventing a pause‐dependent trigger. Whether IPAP might obviate the need for an ICD in some instances warrants further study.