Back to Authors

Taunton, Michael J

0000-0002-7636-0489

Mayo Clinic

Department of Orthopedics, Mayo Clinic, Rochester, Minnesota.

Citations 46

To Lengthen or Revise: Reevaluating Anterior Acetabular Overhang Thresholds in Iliopsoas Impingement After Total Hip Arthroplasty

Journal of Bone and Joint Surgery | October 9, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.2106/jbjs.26.00011 | PMID 42853909

Background: Iliopsoas impingement (IPI) is a known cause of persistent anterior hip pain following total hip arthroplasty (THA). Management of IPI has often relied on an 8-mm anterior acetabular overhang threshold to guide operative treatment, favoring acetabular revision for greater overhang and iliopsoas tenotomy for lesser overhang. These thresholds were initially established on the basis of the outcomes of open tenotomy, and now, with an improved understanding of IPI and the advent of arthroscopic iliopsoas fractional lengthening (IPFL), a review of the 8-mm threshold is warranted. Methods: A retrospective review was performed to identify patients who underwent arthroscopic IPFL following primary THA between 2017 and 2024, with a minimum follow-up of 1 year. Acetabular overhang was measured for all patients using cross-table lateral radiographs, and patients were stratified into <8-mm and ≥8-mm cohorts. Patient-reported outcome measures, reoperations, revisions, and complications were collected and analyzed on the basis of both the classic 8-mm threshold and continuous statistical methods. Results: We evaluated 86 hips undergoing IPFL. There were 83 patients (30 men and 53 women), with a mean age of 63.0 ± 11.2 years; with regard to race, 80 patients were White, 1 patient was Black or African American, and 2 patients listed other race or chose not to disclose. The acetabular overhang was <8 mm for 67 hips and ≥8 mm for 19 hips. The mean follow-up was 2.5 ± 1.6 years (range, 1 to 7.5 years). When comparing patients with <8-mm and ≥8-mm acetabular overhang, we observed no significant differences (p > 0.06) in the preoperative and postoperative visual analog scale (VAS) pain scores, modified Harris hip score, Single Assessment Numeric Evaluation (SANE) score, Tegner activity level, subjective groin pain improvement, subjective hip flexion strength improvement, and overall satisfaction. Reoperation (2.9% compared with 10.5%; p = 0.210) and acetabular revision rates (1.5% compared with 5%; p = 0.387) were not significantly different between the <8-mm and ≥8-mm overhang groups. Conclusions: Arthroscopic IPFL provided satisfactory outcomes for patients with IPI, independent of the magnitude of acetabular overhang. IPFL should be considered for first-line surgical management of IPI refractory to nonoperative management, even in the setting of substantial acetabular overhang, given positive outcomes and low rates of subsequent acetabular revision. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Five-year survival and complications of more than 300 articulating high-dose antibiotic spacers in two-stage revision total hip arthroplasties for infection

The Bone & Joint Journal | September 1, 2026 | Volume: 108-B | Issue: 9 | Pages: 1104-1112

10.1302/0301-620x.108b9.bjj-2026-0551.r1 | PMID 42674571

Aims Two-stage exchange arthroplasty with an antibiotic-eluting cement spacer remains the predominant strategy in the USA for managing chronic periprosthetic joint infection (PJI) following total hip arthroplasty (THA). The aim of this study was to evaluate a commercially available, partially intraoperatively fabricated articulating high-dose antibiotic cement spacer, focusing on survival, complications, and patient-reported outcomes. Methods A total of 298 patients (302 THAs) underwent two-stage exchange arthroplasty for PJI using a specific articulating antibiotic spacer between August 2005 and May 2022. Patients with a previous failed two-stage exchange were excluded, although 121 THAs (302, 40%) had undergone previous PJI-related procedures. The mean age of the patients was 65 years (SD 11), the mean BMI was 32 kg/m 2 (SD 7), and 116 (38%) were female. Most patients were classified as McPherson host B (158; 52%) and limb grade 2 (165; 55%), and 265 (88%) met the 2011 Musculoskeletal Infection Society criteria. The mean follow-up was six years (2 to 16). Results At five years after reimplantation, survival free of reinfection, aseptic rerevision, any rerevision, or any reoperation were 89% (95% CI 85.2 to 93.1), 93% (95% CI 89.3 to 96.1), 86% (95% CI 81.3 to 90.3), and 80% (95% CI 74.7 to 84.9), respectively. Dislocation accounted for most aseptic rerevisions (15/20). McPherson host C (HR 3.7 (95% CI 1.4 to 9.6); p = 0.007) and limb grade 3 (HR 3.3 (95% CI 1.0 to 11.1); p = 0.049) were significantly associated with an increased risk of reinfection. The mean Harris Hip Score at the latest follow-up was 76 (29 to 100). A total of 17 patients underwent revision or removal of a spacer for concerns about persistent infection and two for dislocation of the spacer. Eight patients underwent a non-rerevision reoperation during the spacer interval for wound drainage (n = 5), dislocation of the spacer (n = 2), and perispacer fracture (n = 1). A total of 26 spacer-related complications were treated nonoperatively (15 perispacer fractures, 11 dislocations). Dislocation of the spacer was strongly associated with dislocation after reimplantation (HR 6.2 (95% CI 2.3 to 16.9); p < 0.001). Conclusion This commercially available, partially intraoperatively fabricated articulating spacer showed excellent reinfection-free five-year survival (89%). Spacer-related fracture and dislocation each occurred in 5% of patients. Dislocation of the spacer significantly increased the risk of dislocation following reimplantation, supporting the use of higher-stability bearings in these high-risk patients. Cite this article: Bone Joint J 2026;108-B(9):1104–1112.
Full and Half Cup-Cage Reconstruction of Major Acetabular Defects

Journal of Bone and Joint Surgery | July 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.2106/jbjs.26.00065 | PMID 42475625

We previously reported 5-year results of 57 patients with major acetabular defects (Paprosky 2B through 3B) who underwent full (31) or half (26) cup-cage reconstructions. This study provides an update with 8.8-year mean follow-up. The 10-year cumulative incidence of and survivorship free from revision, reoperation, and complications were estimated. The 10-year cumulative incidence of revision was 14% for full and 12% for half constructs. The incidence of revision for aseptic loosening was 4.3% and 4.6%, respectively. The 10-year survivorship free from aseptic loosening for patients with pelvic discontinuity was 88.9% (95% confidence interval [CI], 70.6% to 100%) and 85.7% (95% CI, 61.8% to 100%), respectively; no patient without pelvic discontinuity required revision for aseptic loosening. The 10-year cumulative incidence of complications was 42% for all patients, including a 15% incidence of dislocation. Thus, both full and half cup-cage constructs provided durable fixation for complex acetabular bone loss at 10 years, although dislocation remains a concern. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Comparison of the Type, Impact, and Resolution of Complications Following Direct Anterior Versus Posterior Approach Total Hip Arthroplasty

JBJS Open Access | July 17, 2026 | Volume: 11 | Issue: 3 | Pages: No page available

10.2106/jbjs.oa.26.00172 | PMID 42465617

Background: Prior studies have reported higher rates of periprosthetic fracture, superficial infection, and neurologic deficit with the direct anterior approach (DAA), and higher rates of dislocation with the posterior approach (PA) for total hip arthroplasty (THA). Despite these differences, the overall clinical burden of complications between approaches remains unclear. The purpose of this study was to compare the profiles, severity, impact, and resolution of 5 clinically important complications between DAA and PA THA. Methods: A retrospective review was conducted of 11,783 consecutive primary THAs performed between 2010 and 2021 across 3 centers within a single healthcare system, using either the DAA (n = 4,451) or the PA (n = 7,332). Complications assessed included dislocation, infection, periprosthetic fracture (PPFx), aseptic loosening, and neurologic deficit. Severity was graded using the Clavien-Dindo classification (I = minor, V = death). Impact was defined by reoperation burden, and outcomes were categorized as resolved or persistent. Kaplan-Meier survivorship and propensity-weighted Cox proportional hazards models were used to compare complication risk. Results: The overall 1-year risk of surgical complications did not differ between DAA and PA (hazard ratio [HR], 0.89; 95% confidence interval [CI], 0.75-1.06; p = 0.208). Dislocation occurred more frequently with PA THA than DAA THA (1.9% vs. 0.4%; HR, 5.20; 95% CI, 3.04-8.90; p < 0.001). Superficial infections were more frequent with the DAA (1.6% vs. 0.8%; HR, 2.43; 95% CI, 1.68-3.53; p < 0.001). The risk of deep infection, PPFx, aseptic loosening, and neurologic deficit did not differ significantly between approaches. Among patients with complications, the proportion classified as severe (Clavien-Dindo III–V) was similar, and adjusted analyses showed no difference in the odds of severe complications (adjusted odds ratio 1.34 for PA vs DAA; 95% CI, 0.95-1.91; p = 0.099). Complication impact and resolution were likewise comparable. Conclusion: Although the profile of complications differed between DAA and PA THA, the severity, early clinical impact, and resolution of complications appeared similar. Notably, DAA was associated with a lower risk of dislocation and a higher risk of superficial infection compared with PA THA. Level of Evidence: Level III , Retrospective Comparative Study. See Instructions for Authors for a complete description of levels of evidence.
Minimum joint space width demonstrates higher inter‐and intra‐observer reliability than Kellgren–Lawrence grading in knee osteoarthritis

Knee Surgery, Sports Traumatology, Arthroscopy | April 14, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ksa.70395 | PMID 41979362

Abstract Purpose The purpose of this systematic review was to compare the inter‐ and intra‐observer reliability of Kellgren–Lawrence (KL) grading versus minimum joint space width (mJSW) measurement on knee radiographs, and to examine the influence of rater type, radiographic view and atlas‐based training. Methods A systematic search of PubMed/MEDLINE, Embase, Scopus and Web of Science was conducted through July 2025 following Preferred Reporting Items for Systematic reviews and Meta‐Analyses (PRISMA) guidelines. Studies reporting inter‐ and/or intra‐observer reliability for KL or mJSW on standard knee radiographs were included. Extracted data included kappa ( κ ) and intraclass correlation coefficient (ICC) values, rater expertise, radiographic view and atlas usage. Raters were categorized as expert, trainee/non‐expert or artificial intelligence (AI)‐assisted/automated. Results Twenty‐four studies (10,394 radiographs) met the inclusion criteria. Inter‐observer reliability was generally higher for mJSW (mean ICC = 0.82 ± 0.17) compared with KL (mean k = 0.72 ± 0.17), with similar trends observed for intra‐observer reliability. Experts and AI‐assisted systems outperformed trainees/non‐experts for both metrics. Reliability improved with semiflexed posteroanterior/Rosenberg views and atlas‐guided training. Conclusion This systematic review demonstrates that mJSW measurement generally shows higher reproducibility than KL grading. Reliability improved with expertise, standardized imaging and structured training, and AI‐assisted approaches performed comparably to expert raters. Quantitative mJSW should complement KL grading, particularly when combined with alignment measures, to enhance consistency and clinical relevance of radiographic assessment. Level of Evidence Level III.
Comparison of Large Language Models with Rules-Based Natural Language Processing Algorithms for Extracting Data from Operative Notes

Journal of Bone and Joint Surgery | March 24, 2026 | Volume: 108 | Issue: 15 | Pages: 1181-1187

10.2106/jbjs.25.01338 | PMID 41875224

Background: We aimed to develop automated data extraction pipelines with large language models (LLMs) to extract registry data from total hip arthroplasty (THA) operative notes and compare the performance with that of existing natural language processing (NLP) algorithms. Methods: We randomly sampled 1,000 primary THA cases from our institutional registry. Two human annotators manually reviewed each operative note for 3 data points: surgical approach, bearing surface, and fixation technique. All labeled THA notes were split into the development set (n = 239) and the testing set (n = 719). We developed a custom data extraction pipeline for each data point by combining an iteratively customized prompt with an LLM. The performance was compared with that of existing rules-based NLP algorithms. Results: The accuracy of LLMs was superior to that of NLP algorithms for all data points: surgical approach (96% compared with 94%), bearing surface (89% compared with 74%), and fixation technique (96% compared with 95%). Furthermore, the LLM accurately inferred the bearing surface for 80% of the notes that were ambiguous about the bearing surface. Conclusions: We developed LLM pipelines for extracting 3 registry-relevant data points from THA operative notes, demonstrating superior performance to existing NLP algorithms. Clinical Relevance: LLMs have the potential to impact clinical care, including the evaluation of electronic medical record free-text data. As registries serve as a cornerstone of orthopaedic evidence, this work demonstrates promise for LLMs to simplify, improve, and democratize the construction of registry databases from operative notes.
Modular dual-mobility constructs outperformed large femoral heads in 299 revision total hip arthroplasties at mid-term follow-up

The Bone & Joint Journal | January 1, 2025 | Volume: 107-B | Issue: 1 | Pages: 58-64

10.1302/0301-620x.107b1.bjj-2024-0170.r1 | PMID 39743935

AimsThe purpose of this study was to directly compare the Modular Dual Mobility (MDM) Mobile Bearing Hip System (Stryker, USA) and large femoral heads (LFHs) in revision total hip arthroplasties (THAs) at mid-term follow-up, with specific emphasis on survival free of re-revision for dislocation, any re-revision, dislocation, and the risk of metal-related complications.MethodsWe identified 299 revision THAs performed at a single tertiary care academic institution from March 2011 to July 2014. Aseptic loosening of the acetabular component (n = 65), dislocation (n = 58), and reimplantation as part of a two-stage exchange protocol (n = 57) were the most common reasons for index revision. MDM constructs were used in 123 cases, and LFHs were used in 176 cases. Mean age was 66 years (28 to 93), mean BMI was 31 kg/m2 (18 to 55), and 45% (n = 136) were female. Mean follow-up was seven years (2 to 12).ResultsThe ten-year survival free of re-revision for dislocation was 99% (95% CI 95 to 100) in the MDM cohort and 91% (95% CI 84 to 96) in the LFH cohort, with a significantly increased risk of re-revision for dislocation in the LFH cohort (HR 7.1 (95% CI 1.3 to 40.8); p = 0.023). The ten-year survival free of any re-revision was 92% (95% CI 82 to 99%) in the MDM cohort and 84% (95% CI 74 to 90) in the LFH cohort with a significantly increased risk of any re-revision in the LFH cohort (HR 2.6 (95% CI 1.1 to 5.9); p = 0.024). The ten-year survival free of any dislocation was 95% (95% CI 85 to 99) in the MDM cohort and 87% (95% CI 78 to 92) in the LFH cohort with a significantly increased risk of any dislocation in the LFH cohort (HR 2.7 (95% CI 1.1 to 6.3); p = 0.028). There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort.ConclusionIn this head-to-head comparison, revision THAs with a MDM construct safely and effectively lowered the risk of re-revision for dislocation, any re-revision, and any dislocation compared to LFH at mid-term follow-up. There were no re-revisions or reoperations for metallosis or corrosion in the MDM cohort.Cite this article: Bone Joint J 2025;107-B(1):58–64.
Outcomes Following Direct Anterior Approach Total Hip Arthroplasty

Journal of Bone and Joint Surgery | December 23, 2024 | Volume: 107 | Issue: 4 | Pages: 356-363

10.2106/jbjs.24.00132 | PMID 39715296

Background: The direct anterior approach (DAA) is a popular approach for primary total hip arthroplasty (THA). However, the contemporary outcomes for DAA THA need further elucidation. Therefore, we aimed to describe implant survivorship, complications, and clinical outcomes after DAA THA. Methods: From our multi-institutional total joint registry, 3,184 patients who had undergone 3,698 primary DAA THA between 2010 and 2019 were identified. The identified patients had a mean age of 65 years and a mean body mass index (BMI) of 29 kg/m 2 , and 53% of patients were female. The indications for revision and reoperation and the incidence of complications were collected and analyzed. Potential risk factors, including age, sex, BMI, and high-volume compared with low-volume operating surgeons, were examined. Descriptive statistics and Kaplan-Meier survivorship with Cox regression analyses were performed. Results: At 10 years following primary DAA THA, the cohort had 96% (95% confidence interval [CI], 95% to 98%) survivorship free of any revision and 94% (95% CI, 92% to 96%) survivorship free of any reoperation. The leading indications for revision were periprosthetic joint infection (PJI) (n = 24; 5-year cumulative incidence, 0.93% [95% CI, 0.6% to 1.5%]), periprosthetic fracture (n = 20; 5-year cumulative incidence, 0.62% [95% CI, 0.4% to 1.0%]), and aseptic loosening (n = 14; 11 femoral, 3 acetabular; 5-year cumulative incidence, 0.84% [95% CI, 0.5% to 1.5%]). A BMI of ≥40 kg/m 2 was found to be significantly associated with PJI (hazard ratio [HR], 6.4; p < 0.001), reoperation (HR, 3.5; p < 0.001), and nonoperative complications (HR, 2.3; p = 0.018). Survivorship free of recurrent instability was 99.6% (95% CI, 99.4% to 99.8%) at 5 and 10 years, and the cumulative incidence of revision for instability was 0.14% at 5 years. Conclusions: In one of the largest published series to date, survivorship following DAA THA was satisfactory at early to intermediate follow-up. The leading indications for revision were PJI, periprosthetic fracture, and aseptic loosening. Instability after DAA THA was uncommon and infrequently led to revision. As a note of caution, a BMI of ≥40 kg/m 2 was identified as a risk factor for adverse outcome after DAA THA. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Prospective Noninvasive Hemoglobin Monitoring in the Outpatient Total Joint Arthroplasty Setting

Journal of Bone and Joint Surgery | December 20, 2024 | Volume: 107 | Issue: 4 | Pages: 364-371

10.2106/jbjs.24.00438 | PMID 39705371

Background: Total joint arthroplasty (TJA) is increasingly being performed as an outpatient (i.e., same-day discharge) procedure. Postoperatively, orthostatic hypotension or pain-related tachycardia can lead to concerns regarding the hemoglobin (Hgb) level of the patient prior to discharge. The purpose of this study was to prospectively assess the reliability and accuracy of, and patient and nurse satisfaction with, postoperative noninvasive hemoglobin (nHgb) monitoring compared with an invasive serum hemoglobin (iHgb) laboratory draw in the outpatient TJA setting. Methods: We prospectively enrolled 200 patients undergoing outpatient unilateral TJA, of whom 157 were ultimately included in our analysis (94 hips, 63 knees). Postoperatively, both nHgb and iHgb values were obtained at a mean of 36 minutes apart. Surveys were completed by patients and nurses. The strength of the agreement between the 2 Hgb monitoring methods was evaluated with use of the Bland-Altman 95% limits of agreement, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Receiver operating characteristic curve analyses were performed to investigate the ability of nHgb monitoring to predict an iHgb of <11.2 g/dL (the 5th-percentile iHgb value). Results: The mean preoperative iHgb was 14.2 ± 1.1 g/dL. The mean postoperative iHgb and nHgb values were 13.3 ± 1.5 and 13.3 ± 1.2 g/dL, respectively. The Bland-Altman 95% limits of agreement were −3.2 and +3.1 g/dL, indicating that 95% of patients’ iHgb values are expected to fall between these limits relative to the nHgb value of the patient. The CCC and ICC were both 0.33. An nHgb cutoff value of <12.7 g/dL had 100% sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Patients reported less pain with the nHgb test than with the iHgb test (mean pain score, 0.0 versus 1.8; p < 0.001), and 97% of patients preferred the nHgb test. Following the nHgb test, 73% of responding patients and 83% of responding nurses were “somewhat more reassured” to “significantly more reassured” about same-day discharge. Conclusions: Routine nHgb testing can rapidly screen patients undergoing outpatient TJA for acute anemia prior to discharge. With an nHgb of <12.7 g/dL, there was perfect sensitivity and 67% specificity for detecting an iHgb of <11.2 g/dL. Most patients and nurses felt more reassured about same-day discharge after nHgb monitoring. Level of Evidence: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.
3D-Printed Metaphyseal Cones in Revision Total Knee Arthroplasties

Journal of Bone and Joint Surgery | June 14, 2024 | Volume: 106 | Issue: 18 | Pages: 1688-1696

10.2106/jbjs.23.01196 | PMID 38875316

Background: Porous metaphyseal cones are frequently utilized during revision total knee arthroplasty (TKA) procedures. The purpose of the present study was to evaluate 3D-printed metaphyseal cones used for revision TKA, with specific emphasis on implant survivorship, radiographic appearance, and clinical outcomes after short-term follow-up. Methods: We identified 740 cones (498 tibial, 242 femoral) that had been inserted during 533 revision TKA procedures that had been performed at a single tertiary care academic institution. Aseptic loosening (n = 199), periprosthetic joint infection (PJI) (n = 183), and instability (n = 84) were the most common reasons for the index revision. Type-2B or 3 bone loss was present in 67% of the knees. The mean age was 66 years, the mean body mass index was 34 kg/m 2 , and 55% of the patients were female. Serial radiographs were reviewed. The mean duration of follow-up was 4 years. Results: The 5-year cumulative incidence of cone revision for aseptic loosening was 1% (95% confidence interval [CI], 0% to 3%). The 5-year cumulative incidence of any cone revision or removal was 6% (95% CI, 4% to 9%). In total, 37 cones (19 femoral, 18 tibial) were revised, with PJI (n = 23; 14 recurrent), periprosthetic femoral fracture (n = 3), arthrofibrosis (n = 3), and aseptic loosening of the femoral component and femoral cone (n = 3) as the most common reasons for cone revision. The 5-year cumulative incidence of any TKA re-revision was 14% (95% CI, 11% to 18%). There were a total of 67 re-revisions, with PJI (n = 38), persistent drainage (n = 6), and extensor mechanism disruption (n = 3) being the most common reasons. Radiographically, 2 unrevised femoral cones and 1 unrevised tibial cone appeared to be possibly loose; all 3 cones were in knees with distal femoral replacements or hinged constructs. Conclusions: This large series showed that 3D-printed titanium metaphyseal cones were very durable at short-term follow-up, with a 5-year cumulative incidence of cone revision for aseptic loosening of 1%. PJI was the most common reason for cone revision and any revision. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.