Back to Authors

Natale, Andrea

0000-0002-5487-0728

Mayo Clinic

St. David’s HealthCare

Citations 14

Effect of Catheter Ablation vs Medical Therapy on Quality of Life Among Patients With Atrial Fibrillation

JAMA | March 15, 2019 | Volume: 321 | Issue: 13 | Pages: 1275

10.1001/jama.2019.0692 | PMID 30874716

2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation

EP Europace | January 17, 2018 | Volume: 20 | Issue: 1 | Pages: e1-e160

10.1093/europace/eux274 | PMID 29016840

2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary

EP Europace | January 5, 2018 | Volume: 20 | Issue: 1 | Pages: 157-208

10.1093/europace/eux275 | PMID 29016841

Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters

Journal of Cardiovascular Electrophysiology | September 11, 2015 | Volume: 27 | Issue: 1 | Pages: 102-109

10.1111/jce.12835 | PMID 26359632

Flex Tip Comparative AblationIntroductionNext‐generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety.MethodsEndocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain.ResultsAverage lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P‐value = 0.013) despite equal mean power and radiofrequency time. High‐temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High‐temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size.ConclusionsThe FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.