Back to Authors

Ehman, Richard

0000-0001-7041-5074

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Citations 27

Detection of transient tissue displacement using wavelet MR elastography: Phantom validation and in vivo human brain repeatability study

Magnetic Resonance in Medicine | June 19, 2025 | Volume: 94 | Issue: 5 | Pages: 1997-2009

10.1002/mrm.30612 | PMID 40534286

AbstractPurposeWhile standard MR elastography (MRE) uses harmonic mechanical waves, there are some applications in which imaging and analysis of transient mechanical motion are of interest. Wavelet MRE has been developed for detecting broadband motion from transient excitation. The goal of this study was to evaluate the accuracy and efficiency of wavelet MRE for transient displacement detection in brain MRE applications.MethodsTransient motion was induced in a gel phantom, while MRE images were acquired using bipolar motion‐encoding gradient (MEG) at multiple frequencies (20–200 Hz). Displacements were estimated using (1) combinations of multiple MEGs forming the wavelet MRE and (2) deconvolution from a single MEG. These estimated displacements were used to calculate the MRE phase for each MEG. Correlation (r2) between the calculated and acquired phases was evaluated.Three healthy volunteers were scanned twice in a clinical scanner using wavelet MRE with an occipital impact. Time‐resolved brain translation, rotation, and maximal principal strain were calculated. Repeatability was assessed both qualitatively and through Pearson correlation.ResultsWavelet MRE outperformed standard MRE in displacement estimation, showing higher correlations between calculated and acquired phase, even with fewer phase offsets. In the volunteer study, consistent temporal motion dynamics and spatial maximal principal strain distributions across repeated scans demonstrated the repeatability of wavelet MRE.ConclusionThis study validated the accuracy and efficiency of wavelet MRE for broadband motion detection and demonstrated its feasibility and repeatability in vivo. This technique shows promise for advancing our understanding of the injury risks and mechanisms associated with sports‐related head trauma.
Three-Dimensional Vector MR Elastography for Evaluating Tissue Mechanical Heterogeneity to Assess Liver Disease Progression

Radiology | April 1, 2025 | Volume: 315 | Issue: 1 | Pages: No page available

10.1148/radiol.242349 | PMID 40167439

Spatial heterogeneity of liver viscoelasticity, measured at three-dimensional vector MR elastography, positively correlated with metabolic dysfunction–associated steatotic liver disease progression.
Population perspectives on benefits and harms of screening for metabolic dysfunction–associated steatotic liver disease

Hepatology | March 19, 2025 | Volume: 83 | Issue: 2 | Pages: 362-373

10.1097/hep.0000000000001311 | PMID 40105977

Background and Aims: Screening for diseases can have psychological impacts, such as anxiety, and requires acceptability from the population to be effective. This study examined the perspectives on the benefits and harms of screening for metabolic dysfunction–associated steatotic liver disease (MASLD) among the general population to optimize screening practices. Approach and Results: A survey was sent to participants enrolled between 2020 and 2024 in a prospective MASLD screening study in Olmsted County, MN. The survey assessed participants' perceived anxiety, stigma, quality of life, preferred screening methods, financial concerns, and lifestyle impacts following screening and diagnosis. Of the 461 participants, 342 (74%) completed the survey. Overall, 14% of participants reported screening-related anxiety, and 14% were concerned about disclosing a potential MASLD diagnosis to others. Among those without a MASLD diagnosis, 99% felt reassured about their liver health, 48% reported an improved quality of life, and 25% made lifestyle changes pertaining to their diet, alcohol use, and physical activity. Of the 77 participants diagnosed with MASLD, 52% experienced some anxiety about their new diagnosis; however, 95% and 97% considered it important to receive an early MASLD diagnosis to mitigate the risk for cirrhosis and cardiovascular disease, respectively. Notably, 79% of diagnosed participants found the diagnosis beneficial in adopting healthier habits, with 30% achieving a >10% weight loss after screening. Conclusion: This population-based survey demonstrates that the perceived benefits of proactive MASLD screening, such as increased awareness, lifestyle changes, and early diagnosis, outweigh the harms. These findings highlight the importance of early screening through patient-centered protocols to improve health outcomes.
Free‐breathing hepatic 2D magnetic resonance elastography

Magnetic Resonance in Medicine | March 11, 2025 | Volume: 93 | Issue: 6 | Pages: 2434-2443

10.1002/mrm.30483 | PMID 40033890

Abstract Purpose To evaluate the test–retest repeatability of a rapid, free‐breathing two‐dimensional (2D) MR elastography (MRE) technique and to assess the reliability of the liver‐stiffness measurements compared with conventional breath‐hold MREs. Methods Fifteen and 115 participants were enrolled in the technical repeatability and measurement equivalence assessment cohorts, respectively. All participants underwent rapid free‐breathing and conventional breath‐hold 2D MRE (twice in repeatability cohort) on 1.5T scanners. Both methods have four phase offsets over one harmonic motion cycle at 60 Hz; one and 10 cycles were collected and processed in breath‐hold and free‐breathing MREs, respectively. The liver stiffness measurements of free‐breathing (LS F ) and breath‐hold MRE (LS B ) were calculated from manually drawn regions of interest. The repeatability coefficients and Spearman correlation were used to assess technical repeatability and measurement agreement between LS F and LS B . Univariable and multivariable linear regressions were performed to identify potential influencing factors, including age, sex, body mass index, and fat fraction, in the measurement agreement between LS B and LS F . Results The repeatability coefficient of free‐breathing 2D MRE is comparable to breath‐hold MRE (LS F : 20.8%, LS B : 20.4%). LS F showed a strong agreement and significant correlation with LS B (LS F = 1.01 × LS B , ρ = 0.94, p < 0.001). The measurement agreement between LS F and LS B was only significantly affected by sex ( p = 0.047) after adjusting for confounding factors of age, body mass index, and fat fraction. Conclusions The nongated, free‐breathing, multislice 2D MRE technique can provide reliable liver stiffness measurements compared with conventional breath‐hold 2D MRE. It could provide a comfortable alternative method with reliable liver stiffness measurements for patients who have difficulty in suspending respiration.
Editorial for “Self‐Gated Radial Free‐Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3T”

Journal of Magnetic Resonance Imaging | July 25, 2024 | Volume: 61 | Issue: 3 | Pages: 1284-1285

10.1002/jmri.29542 | PMID 39052251

Research Reveals a Potential Role for MR Elastography in Preoperative Evaluation of Endometrial Cancer

Radiology | June 4, 2024 | Volume: 311 | Issue: 3 | Pages: No page available

10.1148/radiol.241034 | PMID 38832879

Sex Differences in Aging-related Myocardial Stiffening Quantitatively Measured with MR Elastography

Radiology: Cardiothoracic Imaging | May 23, 2024 | Volume: 6 | Issue: 3 | Pages: No page available

10.1148/ryct.230140 | PMID 38780427

MR elastography–based slip interface imaging (SII) for functional assessment of myofascial interfaces: A feasibility study

Magnetic Resonance in Medicine | March 25, 2024 | Volume: 92 | Issue: 2 | Pages: 676-687

10.1002/mrm.30087 | PMID 38523575

AbstractPurposeAbnormal adherence at functional myofascial interfaces is hypothesized as an important phenomenon in myofascial pain syndrome. This study aimed to investigate the feasibility of MR elastography (MRE)–based slip interface imaging (SII) to visualize and assess myofascial mobility in healthy volunteers.MethodsSII was used to assess local shear strain at functional myofascial interfaces in the flexor digitorum profundus (FDP) and thighs. In the FDP, MRE was performed at 90 Hz vibration to each index, middle, ring, and little finger. Two thigh MRE scans were performed at 40 Hz with knees flexed and extended. The normalized octahedral shear strain (NOSS) maps were calculated to visualize myofascial slip interfaces. The entropy of the probability distribution of the gradient NOSS was computed for the two knee positions at the intermuscular interface between vastus lateralis and vastus intermedius, around rectus femoris, and between vastus intermedius and vastus medialis.ResultsNOSS map depicted distinct functional slip interfaces in the FDP for each finger. Compared to knee flexion, clearer slip interfaces and larger gradient NOSS entropy at the vastus lateralis–vastus intermedius interface were observed during knee extension, where the quadriceps are not passively stretched. This suggests the optimal position for using SII to visualize myofascial slip interface in skeletal muscles is when muscles are not subjected to any additional force.ConclusionThe study demonstrated that MRE‐based SII can visualize and assess myofascial interface mobility in extremities. The results provide a foundation for investigating the hypothesis that myofascial pain syndrome is characterized by changes in the mobility of myofascial interfaces.
Wavelet MRE: Imaging propagating broadband acoustic waves with wavelet‐based motion‐encoding gradients

Magnetic Resonance in Medicine | December 15, 2023 | Volume: 91 | Issue: 5 | Pages: 1923-1935

10.1002/mrm.29972 | PMID 38098427

AbstractPurposeTo demonstrate a novel MR elastography (MRE) technique, termed here wavelet MRE. With this technique, broadband motion sensitivity is achievable. Moreover, the true tissue displacement can be reconstructed with a simple inverse transform.MethodsA wavelet MRE sequence was developed with motion‐encoding gradients based on Haar wavelets. From the phase images' displacement was estimated using an inverse transform. Simulations were performed using a frequency sweep and a transient as ground‐truth motions. A PVC phantom was scanned using wavelet MRE and standard MRE with both transient (one and 10 cycles of 90‐Hz motion) and steady‐state dual‐frequency motion (30 and 60 Hz) for comparison. The technique was tested in a human brain, and motion trajectories were estimated for each voxel.ResultsIn simulation, the displacement information estimated from wavelet MRE closely matched the true motion. In the phantom test, the MRE phase data generated from the displacement information derived from wavelet MRE agreed well with standard MRE data. Testing of wavelet MRE to assess transient motion waveforms in the brain was successful, and the tissue motion observed was consistent with a previous study.ConclusionThe uniform and broadband frequency response of wavelet MRE makes it a promising method for imaging transient, multifrequency motion, or motion with unknown frequency content. One potential application is measuring the response of brain tissue undergoing low‐amplitude, transient vibrations as a model for the study of traumatic brain injury.
Head-to-head comparison of magnetic resonance elastography-based liver stiffness, fat fraction, and T1 relaxation time in identifying at-risk NASH

Hepatology | April 20, 2023 | Volume: 78 | Issue: 4 | Pages: 1200-1208

10.1097/hep.0000000000000417 | PMID 37080558

Background and Aims: The presence of at-risk NASH is associated with an increased risk of cirrhosis and complications. Therefore, noninvasive identification of at-risk NASH with an accurate biomarker is a critical need for pharmacologic therapy. We aim to explore the performance of several magnetic resonance (MR)-based imaging parameters in diagnosing at-risk NASH. Approach and Results: This prospective clinical trial (NCT02565446) includes 104 paired MR examinations and liver biopsies performed in patients with suspected or diagnosed NAFLD. Magnetic resonance elastography-assessed liver stiffness (LS), 6-point Dixon-derived proton density fat fraction (PDFF), and single-point saturation-recovery acquisition-calculated T1 relaxation time were explored. Among all predictors, LS showed the significantly highest accuracy in diagnosing at-risk NASH [AUCLS: 0.89 (0.82, 0.95), AUCPDFF: 0.70 (0.58, 0.81), AUCT1: 0.72 (0.61, 0.82), z-score test z >1.96 for LS vs any of others]. The optimal cutoff value of LS to identify at-risk NASH patients was 3.3 kPa (sensitivity: 79%, specificity: 82%, negative predictive value: 91%), whereas the optimal cutoff value of T1 was 850 ms (sensitivity: 75%, specificity: 63%, and negative predictive value: 87%). PDFF had the highest performance in diagnosing NASH with any fibrosis stage [AUCPDFF: 0.82 (0.72, 0.91), AUCLS: 0.73 (0.63, 0.84), AUCT1: 0.72 (0.61, 0.83), |z| <1.96 for all]. Conclusion: Magnetic resonance elastography-assessed LS alone outperformed PDFF, and T1 in identifying patients with at-risk NASH for therapeutic trials.