Back to Authors

Carter, Rickey E

0000-0002-0818-273X

Mayo Clinic

Mayo Clinic in Florida

Citations 161

Automated low‐contrast pattern recognition algorithm for magnetic resonance image quality assessment

Medical Physics | May 25, 2017 | Volume: 44 | Issue: 8 | Pages: 4009-4024

10.1002/mp.12370 | PMID 28543961

PurposeLow contrast (LC) detectability is a common test criterion for diagnostic radiologic quality control (QC) programs. Automation of this test is desirable in order to reduce human variability and to speed up analysis. However, automation is challenging due to the complexity of the human visual perception system and the ability to create algorithms that mimic this response. This paper describes the development and testing of an automated LC detection algorithm for use in the analysis of magnetic resonance (MR) images of the American College of Radiology (ACR) QC phantom.MethodsThe detection algorithm includes fuzzy logic decision processes and various edge detection methods to quantify LC detectability. Algorithm performance was first evaluated using a single LC phantom MR image with the addition of incremental zero mean Gaussian noise resulting in a total of 200 images. A c‐statistic was calculated to determine the role of CNR to indicate when the algorithm would detect ten spokes. To evaluate inter‐rater agreement between experienced observers and the algorithm, a blinded observer study was performed on 196 LC phantom images acquired from nine clinical MR scanners. The nine scanners included two MR manufacturers and two field strengths (1.5 T, 3.0 T). Inter‐rater and algorithm‐rater agreement was quantified using Krippendorff's alpha.ResultsFor the Gaussian noise added data, CNR ranged from 0.519 to 11.7 with CNR being considered an excellent discriminator of algorithm performance (c‐statistic = 0.9777). Reviewer scoring of the clinical phantom data resulted in an inter‐rater agreement of 0.673 with the agreement between observers and algorithm equal to 0.652, both of which indicate significant agreement.ConclusionsThis study demonstrates that the detection of LC test patterns for MR imaging QC programs can be successfully developed and that their response can model the human visual detection system of expert MR QC readers.
Percutaneous Pericardial Resection

Circulation: Heart Failure | April 11, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.116.003612 | PMID 28396500

Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.
Continuous Glucose Monitor Interference With Commonly Prescribed Medications: A Pilot Study

Journal of Diabetes Science and Technology | March 23, 2017 | Volume: 11 | Issue: 5 | Pages: 936-941

10.1177/1932296817697329 | PMID 28332406

Background: Reliability of continuous glucose monitors (CGM) is a prerequisite for therapeutic dosing of insulin without the need for confirmatory blood glucose meter measurements. Interference of CGMs with commonly prescribed substances has not been extensively evaluated. Methods: We sought to undertake a novel pilot study to determine the susceptibility of FDA-approved CGM systems (Medtronic Guardian Sof-Sensor, Dexcom G4 Platinum) to erroneous readings in the presence of common medications. CGMs were placed on the abdomen of healthy subjects 48 hours prior to study. Subjects were admitted to the Clinical Research Trials Unit (CRTU) on the evening before study and fed a standard supper. The following morning, an oral medication was administered in the fasted state and blood was sampled for 9 hours. CGM values were compared to ambient glucose (measured with YSI) to observe variations in CGM readings. Microdialysis catheters were also placed in the abdomen to sample interstitial fluid (ISF) for drug concentrations. Results: Nineteen healthy drug-naïve subjects without diabetes participated in the study. A drug/substance was tested up to a maximum of nine times on separate occasions. Comparison of CGM glucose patterns to actual plasma glucose concentrations show several drugs, including lisinopril, albuterol, and acetaminophen, appear to interfere with commonly used CGM devices. Wine also interfered with CGM readings. Conclusions: We conclude there is some evidence of CGM interference with lisinopril, albuterol, acetaminophen, atenolol, and red wine. Future studies are required to address interference with newer sensors being approved or in the process of approval.
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography

Journal of Magnetic Resonance Imaging | January 24, 2017 | Volume: 46 | Issue: 2 | Pages: 365-374

10.1002/jmri.25579 | PMID 28117930

PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence: 1Technical Efficacy: Stage 2J. MAGN. RESON. IMAGING 2017;46:365–374
Assessing mNIS+7Ionis and international neurologists' proficiency in a familial amyloidotic polyneuropathy trial

Muscle & Nerve | January 7, 2017 | Volume: 56 | Issue: 5 | Pages: 901-911

10.1002/mus.25563 | PMID 28063170

ABSTRACTIntroductionPolyneuropathy signs (Neuropathy Impairment Score, NIS), neurophysiologic tests (m+7Ionis), disability, and health scores were assessed in baseline evaluations of 100 patients entered into an oligonucleotide familial amyloidotic polyneuropathy (FAP) trial.MethodsWe assessed: (1) Proficiency of grading neurologic signs and correlation with neurophysiologic tests, and (2) clinometric performance of modified NIS+7 neurophysiologic tests (mNIS+7Ionis) and its subscores and correlation with disability and health scores.ResultsThe mNIS+7Ionis sensitively detected, characterized, and broadly scaled diverse polyneuropathy impairments. Polyneuropathy signs (NIS and subscores) correlated with neurophysiology tests, disability, and health scores. Smart Somatotopic Quantitative Sensation Testing of heat as pain 5 provided a needed measure of small fiber involvement not adequately assessed by other tests.ConclusionsSpecially trained neurologists accurately assessed neuropathy signs as compared to referenced neurophysiologic tests. The score, mNIS+7Ionis, broadly detected, characterized, and scaled polyneuropathy abnormality in FAP, which correlated with disability and health scores. Muscle Nerve 56: 901–911, 2017
Characteristics of Biostatistics, Epidemiology, and Research Design Programs in Institutions With Clinical and Translational Science Awards

Academic Medicine | August 30, 2016 | Volume: 92 | Issue: 2 | Pages: 229-236

10.1097/acm.0000000000001350 | PMID 27580435

Purpose To learn the size, composition, and scholarly output of biostatistics, epidemiology, and research design (BERD) units in U.S. academic health centers (AHCs). Method Each year for four years, the authors surveyed all BERD units in U.S. AHCs that were members of the Clinical and Translational Science Award (CTSA) Consortium. In 2010, 46 BERD units were surveyed; in 2011, 55; in 2012, 60; and in 2013, 61. Results Response rates to the 2010, 2011, 2012, and 2013 surveys were 93.5%, 98.2%, 98.3%, and 86.9%, respectively. Overall, the size of BERD units ranged from 3 to 86 individuals. The median FTE in BERD units remained similar and ranged from 3.0 to 3.5 FTEs over the years. BERD units reported more availability of doctoral-level biostatisticians than doctoral-level epidemiologists. In 2011, 2012, and 2013, more than a third of BERD units provided consulting support on 101 to 200 projects. A majority of BERD units reported that between 25% and 75% (in 2011) and 31% to 70% (in 2012) of their consulting was to junior investigators. More than two-thirds of BERD units reported their contributions to the submission of 20 or more non-BERD grant or contract applications annually. Nearly half of BERD units reported 1 to 10 manuscripts submitted annually with a BERD practitioner as the first or corresponding author. Conclusions The findings regarding BERD units provide a benchmark against which to compare BERD resources and may be particularly useful for institutions planning to develop new units to support programs such as the CTSA.
Differentiation of Benign From Metastatic Adrenal Masses in Patients With Renal Cell Carcinoma on Contrast-Enhanced CT

American Journal of Roentgenology | August 24, 2016 | Volume: 207 | Issue: 5 | Pages: 1031-1038

10.2214/ajr.16.16193 | PMID 27556736

Normal-Weight Central Obesity and Mortality Risk

Annals of Internal Medicine | August 18, 2016 | Volume: 165 | Issue: 4 | Pages: 298-299

10.7326/l16-0073 | PMID 27538166

Fast men slow more than fast women in a 10 kilometer road race

PeerJ | July 21, 2016 | Volume: 4 | Issue: No issue available | Pages: e2235

10.7717/peerj.2235 | PMID 27547544

Background. Previous studies have demonstrated that men are more likely than women to slow in the marathon (footrace). This study investigated whether the sex difference in pacing occurs for a shorter race distance. Materials & Methods. Data were acquired from the Bolder Boulder 10 km road race for the years 2008–2013, which encompassed 191,693 performances. There were two pacing measures, percentage change in pace of the first 3 miles relative to the final 3.2 miles and percentage change in pace of the first mile relative to the final 5.2 miles. Pacing was analyzed as a continuous variable and as two categorical variables, as follows: “maintain the pace,” defined as slowing <5% and “marked slowing,” defined as slowing ≥10%. Results. Among the fastest ( men < 48:40; women < 55:27) and second fastest ( men < 53:54; women < 60:28) sex-specific finishing time sextiles, men slowed significantly more than women with both pacing measures, but there were no consistently significant sex differences in pacing among the slower four sextiles. For the fastest sextile, the odds for women were 1.96 (first pacing measure) and 1.36 (second measure) times greater than men to maintain the pace. For the fastest sextile, the odds for women were 0.46 (first measure) and 0.65 (second measure) times that of men to exhibit marked slowing. Multiple regression indicated that being older was associated with lesser slowing, but the sex difference among faster runners persisted when age was controlled. Conclusions. There was a sex difference in pacing during a 10 km race where glycogen depletion is not typically relevant. These results support the hypothesis that the sex difference in pacing partly reflects a sex difference in decision making.