Seizure Detection and Lateralization Using Thalamic Deep Brain Stimulator Recordings

Journal of Clinical Neurophysiology | December 18, 2024 | Volume: 42 | Issue: 3 | Pages: 279-283

10.1097/wnp.0000000000001137 | PMID 39690452

Summary: The lack of reliable seizure detection remains a significant challenge for epilepsy care. A clinical deep brain stimulation (DBS) system provides constrained ambulatory brain recordings; however, limited data exist on the use of DBS recordings for seizure detection and lateralization. We present the case of an 18-year-old patient with drug-resistant focal epilepsy, who had seizure detection and lateralization by DBS recordings. Prior stereotactic-EEG, including a thalamus lead, identified independent left orbitofrontal and mesial temporal onset seizures. Notably, low-frequency thalamic ictal power was significantly elevated relative to baseline awake and sleep states. The patient was subsequently implanted with an anterior nucleus of the thalamus DBS system. Postimplantation, low-frequency power-in-band (5.3–10.3 Hz) recordings were initiated. Nursing staff identified four typical clinical seizures during the inpatient DBS recording period. Thalamic DBS trends contained relative peaks that were coincident with each nurse-reported seizure. Peri-ictal power was uniformly maximal ipsilateral to the seizure network. This case demonstrates the feasibility of seizure detection and lateralization by a thalamic DBS system for some individuals, and suggests DBS sensing parameter selection may be guided by thalamic stereotactic EEG. Further research is necessary to assess the generalizability of DBS seizure detection across individuals and diverse seizure networks.
Automatic Monitoring of High-Frequency Autoimmune Disorder Related Seizures with Wearable Devices

2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 17, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/embc53108.2024.10782939 | PMID 40039653

Effects of epileptic seizures on the quality of biosignals recorded from wearables

Epilepsia | October 7, 2024 | Volume: 65 | Issue: 12 | Pages: 3513-3525

10.1111/epi.18138 | PMID 39373185

Abstract Objective Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri‐ictal periods in performing a feature‐based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring. Methods This study assesses the signal quality of wearable data during peri‐ictal phases of generalized tonic–clonic and focal to bilateral tonic–clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri‐ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS. Results We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre‐ and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity. Significance Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist‐worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.
Data-driven retrieval of population-level EEG features and their role in neurodegenerative diseases

Brain Communications | August 1, 2024 | Volume: 6 | Issue: 4 | Pages: No page available

10.1093/braincomms/fcae227 | PMID 39086629

Abstract Electrophysiologic disturbances due to neurodegenerative disorders such as Alzheimer’s disease and Lewy Body disease are detectable by scalp EEG and can serve as a functional measure of disease severity. Traditional quantitative methods of EEG analysis often require an a-priori selection of clinically meaningful EEG features and are susceptible to bias, limiting the clinical utility of routine EEGs in the diagnosis and management of neurodegenerative disorders. We present a data-driven tensor decomposition approach to extract the top 6 spectral and spatial features representing commonly known sources of EEG activity during eyes-closed wakefulness. As part of their neurologic evaluation at Mayo Clinic, 11 001 patients underwent 12 176 routine, standard 10–20 scalp EEG studies. From these raw EEGs, we developed an algorithm based on posterior alpha activity and eye movement to automatically select awake-eyes-closed epochs and estimated average spectral power density (SPD) between 1 and 45 Hz for each channel. We then created a three-dimensional (3D) tensor (record × channel × frequency) and applied a canonical polyadic decomposition to extract the top six factors. We further identified an independent cohort of patients meeting consensus criteria for mild cognitive impairment (30) or dementia (39) due to Alzheimer’s disease and dementia with Lewy Bodies (31) and similarly aged cognitively normal controls (36). We evaluated the ability of the six factors in differentiating these subgroups using a Naïve Bayes classification approach and assessed for linear associations between factor loadings and Kokmen short test of mental status scores, fluorodeoxyglucose (FDG) PET uptake ratios and CSF Alzheimer’s Disease biomarker measures. Factors represented biologically meaningful brain activities including posterior alpha rhythm, anterior delta/theta rhythms and centroparietal beta, which correlated with patient age and EEG dysrhythmia grade. These factors were also able to distinguish patients from controls with a moderate to high degree of accuracy (Area Under the Curve (AUC) 0.59–0.91) and Alzheimer’s disease dementia from dementia with Lewy Bodies (AUC 0.61). Furthermore, relevant EEG features correlated with cognitive test performance, PET metabolism and CSF AB42 measures in the Alzheimer’s subgroup. This study demonstrates that data-driven approaches can extract biologically meaningful features from population-level clinical EEGs without artefact rejection or a-priori selection of channels or frequency bands. With continued development, such data-driven methods may improve the clinical utility of EEG in memory care by assisting in early identification of mild cognitive impairment and differentiating between different neurodegenerative causes of cognitive impairment.
How accurate do self‐reported seizures need to be for effective medication management in epilepsy?

Epilepsia | May 22, 2024 | Volume: 65 | Issue: 7 | Pages: No page available

10.1111/epi.18019 | PMID 38776216

AbstractStudies suggest that self‐reported seizure diaries suffer from 50% under‐reporting on average. It is unknown to what extent this impacts medication management. This study used simulation to predict the seizure outcomes of a large heterogeneous clinic population treated with a standardized algorithm based on self‐reported seizures. Using CHOCOLATES, a state‐of‐the‐art realistic seizure diary simulator, 100 000 patients were simulated over 10 years. A standard algorithm for medication management was employed at 3 month intervals for all patients. The impact on true seizure rates, expected seizure rates, and time‐to‐steady‐dose were computed for self‐reporting sensitivities 0%–100%. Time‐to‐steady‐dose and medication use mostly did not depend on sensitivity. True seizure rate decreased minimally with increasing self‐reporting in a non‐linear fashion, with the largest decreases at low sensitivity rates (0%–10%). This study suggests that an extremely wide range of sensitivity will have similar seizure outcomes when patients are clinically treated using an algorithm similar to the one presented. Conversely, patients with sensitivity ≤10% would be expected to benefit (via lower seizure rates) from objective devices that provide even small improvements in seizure sensitivity.
Minimum clinical utility standards for wearable seizure detectors: A simulation study

Epilepsia | February 17, 2024 | Volume: 65 | Issue: 4 | Pages: 1017-1028

10.1111/epi.17917 | PMID 38366862

AbstractObjectiveEpilepsy management employs self‐reported seizure diaries, despite evidence of seizure underreporting. Wearable and implantable seizure detection devices are now becoming more widely available. There are no clear guidelines about what levels of accuracy are sufficient. This study aimed to simulate clinical use cases and identify the necessary level of accuracy for each.MethodsUsing a realistic seizure simulator (CHOCOLATES), a ground truth was produced, which was then sampled to generate signals from simulated seizure detectors of various capabilities. Five use cases were evaluated: (1) randomized clinical trials (RCTs), (2) medication adjustment in clinic, (3) injury prevention, (4) sudden unexpected death in epilepsy (SUDEP) prevention, and (5) treatment of seizure clusters. We considered sensitivity (0%–100%), false alarm rate (FAR; 0–2/day), and device type (external wearable vs. implant) in each scenario.ResultsThe RCT case was efficient for a wide range of wearable parameters, though implantable devices were preferred. Lower accuracy wearables resulted in subtle changes in the distribution of patients enrolled in RCTs, and therefore higher sensitivity and lower FAR values were preferred. In the clinic case, a wide range of sensitivity, FAR, and device type yielded similar results. For injury prevention, SUDEP prevention, and seizure cluster treatment, each scenario required high sensitivity and yet was minimally influenced by FAR.SignificanceThe choice of use case is paramount in determining acceptable accuracy levels for a wearable seizure detection device. We offer simulation results for determining and verifying utility for specific use case and specific wearable parameters.
Spike ripples localize the epileptogenic zone best: an international intracranial study

Brain | February 7, 2024 | Volume: 147 | Issue: 7 | Pages: 2496-2506

10.1093/brain/awae037 | PMID 38325327

Abstract We evaluated whether spike ripples, the combination of epileptiform spikes and ripples, provide a reliable and improved biomarker for the epileptogenic zone compared with other leading interictal biomarkers in a multicentre, international study. We first validated an automated spike ripple detector on intracranial EEG recordings. We then applied this detector to subjects from four centres who subsequently underwent surgical resection with known 1-year outcomes. We evaluated the spike ripple rate in subjects cured after resection [International League Against Epilepsy Class 1 outcome (ILAE 1)] and those with persistent seizures (ILAE 2–6) across sites and recording types. We also evaluated available interictal biomarkers: spike, spike-gamma, wideband high frequency oscillation (HFO, 80–500 Hz), ripple (80–250 Hz) and fast ripple (250–500 Hz) rates using previously validated automated detectors. The proportion of resected events was computed and compared across subject outcomes and biomarkers. Overall, 109 subjects were included. Most spike ripples were removed in subjects with ILAE 1 outcome (P < 0.001), and this was qualitatively observed across all sites and for depth and subdural electrodes (P < 0.001 and P < 0.001, respectively). Among ILAE 1 subjects, the mean spike ripple rate was higher in the resected volume (0.66/min) than in the non-removed tissue (0.08/min, P < 0.001). A higher proportion of spike ripples were removed in subjects with ILAE 1 outcomes compared with ILAE 2–6 outcomes (P = 0.06). Among ILAE 1 subjects, the proportion of spike ripples removed was higher than the proportion of spikes (P < 0.001), spike-gamma (P < 0.001), wideband HFOs (P < 0.001), ripples (P = 0.009) and fast ripples (P = 0.009) removed. At the individual level, more subjects with ILAE 1 outcomes had the majority of spike ripples removed (79%, 38/48) than spikes (69%, P = 0.12), spike-gamma (69%, P = 0.12), wideband HFOs (63%, P = 0.03), ripples (45%, P = 0.01) or fast ripples (36%, P < 0.001) removed. Thus, in this large, multicentre cohort, when surgical resection was successful, the majority of spike ripples were removed. Furthermore, automatically detected spike ripples localize the epileptogenic tissue better than spikes, spike-gamma, wideband HFOs, ripples and fast ripples.
Technical Considerations in EEG Source Imaging

Journal of Clinical Neurophysiology | January 5, 2024 | Volume: 41 | Issue: 1 | Pages: 2-7

10.1097/wnp.0000000000001029 | PMID 38181382

Summary: EEG source imaging is an established technique for identifying the origin of interictal and ictal epileptiform discharges in patients with epilepsy, and it is an important tool in neurophysiology research. Accurate and reliable EEG source imaging requires appropriate choices of how the head, skull, and scalp are modeled, and understanding of the different approaches to modeling is important to guide these choices. Similarly, numerous different approaches to modeling the electrical sources within the brain exist, and appropriate understanding of the strengths and limitations of each are essential to obtaining accurate, reliable, and interpretable solutions. This review aims to describe the essential theoretical basis for these head and source models while also discussing the practical implications of each in clinical or research applications.
EEG Source Localization in Temporal Encephaloceles: Concordance With Surgical Resection and Clinical Outcomes

Journal of Clinical Neurophysiology | September 27, 2023 | Volume: 41 | Issue: 6 | Pages: 515-521

10.1097/wnp.0000000000001021 | PMID 37756021

Purpose: Temporal encephaloceles are a cause of drug-resistant temporal lobe epilepsy; however, their relationship with epileptogenesis is unclear, and optimal surgical resection is uncertain. EEG source localization (ESL) may guide surgical decision-making. Methods: We reviewed patients at Mayo Clinic Rochester with drug-resistant temporal lobe epilepsy and temporal encephaloceles, who underwent limited resection and had 1-year outcomes. EEG source localization was performed using standard density scalp EEG of ictal and interictal activity. Distance from dipole and standardized low-resolution brain electromagnetic tomography (sLORETA) solutions to the encephalocele were measured. Concordance of ESL with encephalocele and surgical resection was compared with 1-year surgical outcomes. Results: Seventeen patients met criteria. The mean distances from ESL results to encephalocele center for dipole and sLORETA analyses were 23 mm (SD 9) and 22 mm (SD 11), respectively. Ten patients (55.6%) had Engel I outcomes at 1 year. Dipole-encephalocele distance and sLORETA-encephalocele distance were significantly longer in patients with Engel I outcome and patients whose encephalocele was contained by sLORETA had worse outcome as well; however, multiple logistic regression analysis found that only containment of encephalocele by the sLORETA current density was significant (P < 0.05), odds ratio 0.12 (95% confidence interval [0.021, 0.71]). Conclusions: EEG source localization of scalp EEG localizes near encephaloceles, however, typically not in the encephalocele itself; this may be due to scalp EEG sampling propagated activity or alternatively that the seizure onset zone extends beyond the herniated cortex. Surprisingly, we observed increased ESL to encephalocele distances in patients with excellent surgical outcomes. Larger cohort studies including intracranial EEG data are needed to further explore this finding.
Temporo-Parietal Extraventricular Approach for Deep Brain Stimulation Targeting the Anterior Nucleus of the Thalamus: Institutional Experience

Neurosurgery | July 21, 2023 | Volume: 93 | Issue: 6 | Pages: 1393-1406

10.1227/neu.0000000000002600 | PMID 37477444

BACKGROUND AND OBJECTIVES: The anterior nucleus of the thalamus (ANT) is a common target for deep brain stimulation (DBS) for drug-resistant epilepsy (DRE). However, the surgical approach to the ANT remains challenging because of its unique anatomy. This study aims to summarize our experience with the posterior temporo-parietal extraventricular (TPEV) approach targeting the ANT for DBS in DRE. METHODS: We performed a retrospective analysis of patients with DRE who underwent ANT-DBS using the TPEV approach between January 2011 and February 2021. Subjects with at least 6-month follow-up were eligible. The final lead position and number of active contacts targeting the anteroventral nucleus (AV) of the ANT were assessed using Lead-DBS. Mean seizure frequency reduction percentage and responder rate (≥50% decrease in seizure frequency) were determined. RESULTS: Thirty-one patients (mean age: 32.9 years; 52% female patients) were included. The mean follow-up period was 27.6 months ± 13.9 (29, 16-36). The mean seizure frequency reduction percentage was 65% ± 26 (75, 50-82). Twenty-six of 31 participants (83%) were responders, P < .001. Two subjects (6%) were seizure-free for at least 6 months at the last evaluation. Antiepileptic drugs dose and/or number decreased in 17/31 subjects (55%). The success rate for placing at least 1 contact at AV was 87% (27/31 patients) bilaterally. The number of active contacts at the AV was significantly greater in the responder group, 3.1 ± 1.3 (3, 2-4) vs 1.8 ± 1.1 (2, 1-2.5); P = .041 with a positive correlation between the number of active contacts and seizure reduction percentage; r = 0.445, R 2 = 0.198, P = .012. CONCLUSION: The TPEV trajectory is a safe and effective approach to target the ANT for DBS. Future studies are needed to compare the clinical outcomes and target accuracy with the standard approaches.