Citations 148

Impact of Anemia on Clinical Outcomes in Atrial Fibrillation Patients on Oral Anticoagulants: A Prognostic Meta‐Analysis

Journal of Cardiovascular Electrophysiology | December 24, 2024 | Volume: 36 | Issue: 2 | Pages: 430-448

10.1111/jce.16537 | PMID 39716396

ABSTRACTBackgroundAnemia is frequently observed as a comorbidity in atrial fibrillation (AF), especially in elderly patients and in those on anticoagulation. This has been associated with poor clinical outcomes. We aim to investigate the impact of anemia on clinical outcomes in patients with AF on oral anticoagulation.MethodsWe comprehensively searched PubMed, WOS, SCOPUS, EMBASE, and CENTRAL through March 2024 and conducted a prognostic systematic review and meta‐analysis. All analyses were performed using R V. 4.3.1. This meta‐analysis was registered at PROSPERO (CRD42024556023).ResultsWe included 23 studies comprising 286,781 patients for analysis. Anemia had a significant association with an 84% increase in risk of major bleeding (HR: 1.84 with 95% CI [1.59, 2.13], p < 0.01), a 32% increase in the risk of intracranial hemorrhage (HR: 1.32 with 95% CI [1.10, 1.58], p < 0.01), a 98% increase in the risk of gastrointestinal bleeding (HR: 1.98 with 95% CI [1.67, 2.35], p < 0.01), and a 91% increase in the risk of all‐cause mortality (HR: 1.91 with 95% CI [1.46, 2.51], p < 0.01). However, the impact of anemia did not significantly affect the risk of stroke, transient ischemic stroke (TIA), or systemic embolism (HR: 1.07 with 95% CI [0.93, 1.22], p = 0.36).ConclusionAnemia was significantly associated with an increased risk of major bleeding, intracranial hemorrhage, gastrointestinal bleeding, and all‐cause mortality. However, anemia did not significantly impact stroke, TIA, or systemic embolism.
Discrimination between RA and LA Sinus Rhythms using machine learning approach

2024 46th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 17, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-4

10.1109/embc53108.2024.10782285 | PMID 40039295

Abstract 4147722: Clinical impact of new severe tricuspid regurgitation following device lead extraction

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4147722

Introduction: Tricuspid regurgitation (TR) is a common complication of right ventricle lead extraction (RVLE) in 5 to 10% of cases. This study aims to identify clinical outcomes such as predictors of heart failure hospitalization, need for tricuspid valve intervention, and death among patients with new severe TR after device lead removal (DLR). Methods: Patients who underwent DLR (pacemaker/ICD) between 3/1997 and 3/2024 were identified. Those who had an echocardiogram before and after RVLE with evidence of new severe TR were included. Cox univariable regression controlling for current age was used to assess association with death. Prentice Williams Peterson total time (PWPTT) Cox univariable regression was used to determine the rate of heart failure hospitalization up to three events per subject. Bivariable cox regression was used to control for ejection fraction for ICD and coil removal. Analysis was conducted using Stata IC16. Results: We identified 2,122 people who underwent RVLE, of whom 90 (4.24%) developed new severe TR and were included in the analysis. There were 68 hospitalizations among 38 people at a median of 2 years following lead extraction (IQR 0.57 to 4.5 years). The rate of hospitalization was 11.60 [9.14 to 14.71] per 100 person-years. Removal of an ICD was associated with increased hospitalization (HR 5.48 p<0.001) but not mortality (HR 1.21, p=0.707). Removal of a single coil ICD lead was associated with increased hospitalization rate (HR 3.01, p=0.031) but not mortality (HR =0.51, p=0.380). Removal of dual coil ICD lead was associated with more than a tenfold increase in hospitalization rate (HR 11.55, p=0.001) and four times the mortality rate (HR 4.05, p=0.031) (Figures 1&2). The presence of an abandoned (pacemaker/ICD) lead was associated with increased hospitalization (HR 5.75, p=0.004) and mortality (HR4.95, p=0.034). There was no change in hospitalization rate following tricuspid valve replacement (HR 1.33, p=0.716, n=18). Conclusion: Among people with new severe TR following DLR, the characteristics of the leads are strongly correlated with morbidity and mortality.
Abstract 4142252: Impact of Diagnosis to Ablation Time on Recurrence of Atrial Fibrillation and Clinical Outcomes after Catheter Ablation: A Systematic Review and Meta-analysis with Reconstructed Time-to-Event Data.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4142252

Background: Current clinical guidelines emphasize the significance of rhythm control with catheter ablation but lack guidance on the timing after diagnosing atrial fibrillation (AF). Purpose: We aim to investigate the latest evidence on the impact of diagnosis to ablation time (DAT) on AF recurrence, all-cause mortality, stroke, and heart failure (HF) after AF catheter ablation. Methods: We comprehensively searched PubMed, WOS, SCOPUS, EMBASE, and CENTRAL through February 2024. We conducted a pair-wise and prognostic systematic review and meta-analysis with a reconstructed time-to-event data meta-analysis. All analyses were performed using R V. 4.3.1. PROSPERO ID: CRD42024525542. Results: With the inclusion of 22 studies, our cohort comprised a total of 42,101 patients. Regarding pair-wise meta-analysis, shorter DAT was significantly associated with a decreased incidence of AF recurrence across paroxysmal and persistent AF subgroups. Moreover, DAT ≤ one year was significantly associated with a decreased incidence of all-cause mortality (RR: 0.73 with 95% CI [0.59, 0.92], P< 0.01) with a trend toward lowering the risk of stroke (RR: 0.80 with 95% CI [0.62, 1.03], P= 0.08). However, there was no significant difference between DAT ≤ one year and DAT > one year in HF. Regarding adjusted prognostic meta-analysis, longer DAT was significantly associated with an increased risk of AF recurrence (P < 0.01). Our reconstructed Kaplan Meier showed that DAT > one year was significantly associated with a 50% increase in the risk of AF recurrence compared to DAT ≤ one year (HR: 1.50 with 95% CI [1.42, 1.58], P< 0.00001) over 60 months follow-up. Conclusion: Our meta-analysis strongly underscores the critical importance of a short DAT in significantly reducing AF recurrence and all-cause mortality, with a trend toward lowering stroke risk, though no significant impact on HF was observed. Early ablation proves beneficial not only for patients with paroxysmal AF but also for those with persistent AF. These findings suggest that minimizing DAT can markedly improve AF outcomes, warranting further investigation to optimize treatment strategies.
Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches

Circulation: Arrhythmia and Electrophysiology | July 25, 2024 | Volume: 17 | Issue: 8 | Pages: No page available

10.1161/circep.123.012663 | PMID 39051111

BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.
Association between COVID‐19 vaccination and atrial arrhythmias in individuals with cardiac implantable electronic devices

Journal of Cardiovascular Electrophysiology | July 23, 2024 | Volume: 35 | Issue: 9 | Pages: 1828-1836

10.1111/jce.16372 | PMID 39039649

AbstractIntroductionThe impact of mRNA‐based coronavirus disease‐2019 (COVID‐19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown.MethodsBIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID‐19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub‐analyses comparing the effects of the influenza vaccine against the COVID‐19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID‐19 vaccine and non‐vaccinated patients was also performed.ResultsFirst and second doses of the COVID‐19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID‐19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID‐19 vaccine. No significant difference in device therapies was seen pre‐ and postvaccination.ConclusionsThough we report a small but significant increase in the number of CIED‐detected AAs following vaccination for COVID‐19 over a 3‐month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high‐risk groups, specifically males over 70 years of age, following vaccination.
Trends and disparities in cardiac implantable electronic device infection‐related mortality in the United States

Journal of Cardiovascular Electrophysiology | May 10, 2024 | Volume: 35 | Issue: 7 | Pages: 1487-1489

10.1111/jce.16298 | PMID 38725220

AbstractIntroductionWe performed a cross‐sectional study using the Centers for Disease Control and Prevention's (CDC's) Wide‐Ranging Online Data for Epidemiologic Research (WONDER) database to analyze the trends in cardiac implantable electronic device (CIED) infection‐related mortality from 1999 to 2020.MethodsWe analyzed the death certificate data from the CDC WONDER database from 1999 to 2020 for CIED infections in the US population aged ≥25 years using International Classification of Diseases, Tenth Revision (ICD‐10) codes, listed as the underlying or contributing cause of death. Age‐adjusted mortality rates (AAMR) and 95% confidence intervals (CIs) were computed per 1 million population by standardizing crude mortality rates to the 2000 US census population. To assess annual mortality trends, we employed the Joinpoint regression model, calculating the annual percent change (APC) in AAMR and corresponding 95% CIs.ResultsOverall, there was an observed declining trend in AAMRs related to CIED infection‐related mortality. Males accounted for 55% of the total deaths, with persistently higher AAMRs compared to females over the study duration. Both males and females had an overall decreasing trend in AAMRs throughout the study duration. On race/ethnicity stratified analysis, non‐Hispanic (NH) Blacks exhibited the highest overall AAMR, followed by NH American Indians or Alaska Natives, NH Whites, Hispanic or Latinos, and NH Asian or Pacific Islanders. On a stratified analysis based on region, the South region had the highest overall AAMR, followed by the Midwest, West, and Northeast regions.ConclusionOur study demonstrates a significant decline in CIED infection‐related mortality in patients over the last two decades. Notable gender, racial/ethnic, and regional differences exist in the rates of mortality related to CIED infections.
Abstract 13068: Use of Cardiac Implantable Electronic Devices in Carcinoid Heart Disease

Circulation | April 23, 2024 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.13068

Introduction: Carcinoid heart disease (CHD) is a rare sequelae of hormonally active neuroendocrine tumors that often requires cardiac surgical intervention. Little is reported on cardiac implantable electronic device (CIED) implantation in the CHD patient population. Hypothesis: We sought to establish the safety and efficacy of CIED implantation in patients with CHD. Methods: We retrospectively reviewed patients with a diagnosis of CHD who underwent CIED implantation at our institution (Mayo Clinic) and evaluated indications for implant, perioperative complications, and mortality. Results: A total of 27 patients with a cumulative follow up of 75 patient-years were identified during the study period. The most common indication for device implant was high grade atrioventricular block (n=18, 66.7%). 14 (51.8%) had baseline conduction disease and 26 (96.2%) underwent cardiac surgery prior to CIED implant. The majority of devices implanted were dual chamber permanent pacemakers (PPM) (n=17, 63.0%), while other devices included single chamber PPM, epicardial PPM, chronic resynchronization devices, and intracardiac defibrillators. Peri-operative complication occurred in 6 patients (22.2%), with 2 patients requiring ICU level care. No patient suffered carcinoid crisis during implantation and there was no peri-implant mortality. Long term, 3 patients required device extraction: 1 for infection, 1 for lead related pain, and 1 for generator migration. The median time to death from implant was 2.5 years, with one-year mortality at 15%. Conclusions: In this unique cohort of patients with CHD, CIED can be performed safely. CIED most often occurred in the post cardiac surgical period and carcinoid crisis was uncommon.
Abstract 9770: Anatomic Findings and Myocardial Extensions Into the Thoracic Venous Connections of the Heart

Circulation | April 23, 2024 | Volume: 124 | Issue: suppl_21 | Pages: No page available

10.1161/circ.124.suppl_21.a9770

Introduction: Cardiac veins serve as substrate for arrhythmogenesis, and are especially involved as foci in atrial fibrillation. Understanding cardiac vein anatomy along with myocardial extension into these structures can improve electrophysiological mapping and electrical isolation of arrhythmogenic substrate. Accurately defining cardiac vein anatomy is critical in improving success of ablation therapy for atrial fibrillation. Methods: We performed measurements on 620 formalin-fixed autopsy hearts explanted from October 1998 to July 2003. The integrity of the thoracic veins and their cardiac connections were examined and systematic measurements of the superior and inferior vena cavae, azygous vein, vein of Marshall, coronary sinus, and pulmonary veins were performed and data were analyzed using univariate statistics. Results: We found that muscular extensions into the pulmonary veins were visible in 99% of the examined hearts, and were circumferential around the vein ostia (99.6%). Muscle extension into the SVC was found in 78% of examined hearts. These extensions were largely circumferential around the ostium (39%), but were also found to be asymmetric in a majority of hearts. Asymmetry was found in hearts with longer muscle extensions; no symmetry was observed in extensions greater than 0.8cm. Muscle extensions into the IVC were not seen. Occasionally, macroscopic muscle extensions into the azygous vein were visible (6%). The vein of Marshall was found to be patent to probing in the majority of hearts examined (72%) and was almost always overlying the lateral left atrial endocardial ridge. Conclusions: Our data suggest that all pulmonary veins need to be electrically isolated during atrial fibrillation ablation because of the almost universal presence of myocardial tissue extending into the veins. Mapping of the SVC should be done circumferentially and if potentials are noted isolation should also be performed. The IVC did not have muscle extensions and is unlikely to be a site of arrhythmogenesis. The azygous vein occasionally had muscle extensions and thus requires mapping and possible isolation. The vein of Marshall can be a substrate for arrhythmogenesis and is accessible for ablation by targeting the lateral left atrial endocardial ridge.
Electrical storm after left ventricular assist device (LVAD) implantation

Journal of Cardiovascular Electrophysiology | April 9, 2024 | Volume: 35 | Issue: 6 | Pages: 1196-1202

10.1111/jce.16275 | PMID 38590268

AbstractIntroductionVentricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years.MethodsWe performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed.ResultsA total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5–297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545 (IQR 152–1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39–2.64, p < .001).ConclusionFollowing LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre‐implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.