Transvenous Stimulation of the Renal Sympathetic Nerves Increases Systemic Blood Pressure: A Potential New Treatment Option for Neurocardiogenic Syncope
Journal of Cardiovascular Electrophysiology | June 5, 2014 | Volume: 25 | Issue: 10 | Pages: 1115-1118
Renal Vein Stimulation Increases Blood PressureBackgroundNeurocardiogenic syncope (NCS) is a common and sometimes debilitating disorder, with no consistently effective treatment. NCS is due to a combination of bradycardia and vasodilation leading to syncope. Although pacemaker devices have been tried in treating the bradycardic aspect of NCS, no device‐based therapy exists to treat the coexistent vasodilation that occurs. The renal sympathetic innervation has been the target of denervation to treat hypertension. We hypothesized that stimulation of the renal sympathetic nerves can increase blood pressure and counteract vasodilation in NCS.Methods and ResultsHigh‐frequency stimulation (800–900 pps, 10 V, 30–200 seconds) was performed using a quadripolar catheter in the renal vein of 7 dogs and 1 baboon. A significant increase in blood pressure (BP; mean [SD] systolic BP 117 [±28] vs. 128 [±33], diastolic BP 75 [±19] vs. 87 [±29] mmHg) was noted during the stimulation, which returned to baseline after cessation of stimulation. The mean increase in systolic and diastolic BP was 13.0 (±3.3) (P = 0.006) and 10.2 (±4.6) (P = 0.08), respectively.ConclusionWe report the first ever study of feasibility and safety of high‐frequency electrical stimulation of the renal sympathetic innervation to increase BP in animal models. This has potential applications in the treatment of hypotensive states such as NCS.
Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975
Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 7 | Pages: 781-786
Electromagnetic Interference with Ventricular Assist DeviceBackgroundHemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.MethodsImpella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.ResultsSevere EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.ConclusionConcurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.
The anatomic basis for ventricular arrhythmia in the normal heart: What the student of anatomy needs to know
Ablation and Mapping of the Conus Papillary MuscleCatheter ablation is an increasingly used and successful treatment choice for right ventricular outflow tract (RVOT) arrhythmias. While the role of endocavitary structures and the regional morphology of the ventricular inflow tract and the right atrium as a cause for difficulty with successful ablation are well described, similar issues within the RVOT are not well understood. It is also not commonly appreciated that one of the papillary muscles is located within the proximal RVOT. We report 3 patients in which ventricular arrhythmia was targeted and ablated in the conus papillary muscle. The anatomic features, potential role of the fascicular conduction system, and unique challenges with mapping arrhythmia arising from this structure are discussed.
Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale
Background— A patent foramen ovale (PFO) may permit arterial embolization of thrombi that accumulate on the leads of cardiac implantable electronic devices in the right-sided cardiac chambers. We sought to determine whether a PFO increases the risk of stroke/transient ischemic attack (TIA) in patients with endocardial leads. Methods and Results— We retrospectively evaluated all patients who had endocardial leads implanted between January 1, 2000, and October 25, 2010, at Mayo Clinic Rochester. Echocardiography was used to establish definite PFO and non-PFO cohorts. The primary end point of stroke/TIA consistent with a cardioembolic etiology and the secondary end point of mortality during postimplantation follow-up were compared in PFO versus non-PFO patients with the use of Cox proportional hazards models. We analyzed 6075 patients (364 with PFO) followed for a mean 4.7±3.1 years. The primary end point of stroke/TIA was met in 30/364 (8.2%) PFO versus 117/5711 (2.0%) non-PFO patients (hazard ratio, 3.49; 95% confidence interval, 2.33–5.25; P <0.0001). The association of PFO with stroke/TIA remained significant after multivariable adjustment for age, sex, history of stroke/TIA, atrial fibrillation, and baseline aspirin/warfarin use (hazard ratio, 3.30; 95% confidence interval, 2.19–4.96; P <0.0001). There was no significant difference in all-cause mortality between PFO and non-PFO patients (hazard ratio, 0.91; 95% confidence interval, 0.77–1.07; P =0.25). Conclusions— In patients with endocardial leads, the presence of a PFO on routine echocardiography is associated with a substantially increased risk of embolic stroke/TIA. This finding suggests a role of screening for PFOs in patients who require cardiac implantable electronic devices; if a PFO is detected, PFO closure, anticoagulation, or nonvascular lead placement may be considered.
Outflow Tract Ventricular Tachycardia Mapped to the Coronary Arteries: Anatomical Correlates and Management Strategies
Journal of Cardiovascular Electrophysiology | August 2, 2013 | Volume: 24 | Issue: 12 | Pages: 1416-1422
Coronary Artery Ventricular Tachycardia. Background The coronary cusps have been well described as a successful site for ablation in patients with symptomatic outflow tract ventricular tachycardia. The earliest site of activation is rarely found at the ostia or into the main coronary arteries. The exact anatomic substrate, diagnostic characteristics, and therapeutic approaches for such instances are poorly understood. Methods We retrospectively reviewed outflow tract ventricular arrhythmia (OTVA) ablations done at Mayo Clinic Rochester from 2003 to 2011 (total VT: 414; outflow tract VT: 106). Three cases were identified where the earliest site of activation was not within the cusp but rather at or within the coronary ostia (3/414 for all VT: 0.7%; 3/106 for all OTVT: 2.8%). Results In 1 patient, the left main coronary artery (LMCA) was found to have electrograms (EGMs) recorded with bipolar mapping that preceded activation in the cusps or the left ventricular outflow tract. In 2 cases, the right coronary ostium and proximal right coronary artery recorded the earliest signals. Intracardiac echocardiographic guidance was used to successfully ablate these arrhythmias targeting the aortic route (1 patient) or the right coronary cusp (2 patients), and essentially isolated the focus of origin from the ventricular outflow tracts. Detailed mapping of surrounding structures, including the atrial appendages, the contralateral outflow tract, and the coronary venous system excluded far‐field mapping in the artery as a cause for early activation at the ostial location. Local EGM characteristics suggested an unusually lengthy supravalvar myocardial extension as the likely arrhythmogenic substrate. Ablation was successful without coronary arterial or valvular injury and without valvular or root stenosis. Conclusions Endocardial ablation isolating foci of origin in the vicinity of the coronary ostia is a challenging procedure but can be performed safely with appropriate visualization and is effective in the treatment of OTVA.
Cardioembolic Stroke in Patients with Patent Foramen Ovale and Implanted Cardiac Leads
Pacing and Clinical Electrophysiology | October 19, 2012 | Volume: 36 | Issue: 1 | Pages: 50-54
Implanted cardiac devices, including pacemakers, defibrillators, and resynchronization devices, are known to develop thrombus on their intravascular leads. Patent foramen ovale (PFO) occurs in approximately one‐quarter of the adult population. It is unclear whether paradoxical cardioembolism and clinically relevant stroke occur in patients with implanted cardiac leads and PFO. We present a case series of four patients with cardioembolic stroke, presumed to arise from intravascular cardiac leads and associated PFO that required device closure of the PFO.(PACE 2013; 36:50–54)