Citations 119

Improved Multiscale Entropy Technique with Nearest-Neighbor Moving-Average Kernel for Nonlinear and Nonstationary Short-Time Biomedical Signal Analysis

Journal of Healthcare Engineering | March 5, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-13

10.1155/2018/8632436 | PMID 29707188

Analysis of biomedical signals can yield invaluable information for prognosis, diagnosis, therapy evaluation, risk assessment, and disease prevention which is often recorded as short time series data that challenges existing complexity classification algorithms such as Shannon entropy (SE) and other techniques. The purpose of this study was to improve previously developed multiscale entropy (MSE) technique by incorporating nearest-neighbor moving-average kernel, which can be used for analysis of nonlinear and non-stationary short time series physiological data. The approach was tested for robustness with respect to noise analysis using simulated sinusoidal and ECG waveforms. Feasibility of MSE to discriminate between normal sinus rhythm (NSR) and atrial fibrillation (AF) was tested on a single-lead ECG. In addition, the MSE algorithm was applied to identify pivot points of rotors that were induced in ex vivo isolated rabbit hearts. The improved MSE technique robustly estimated the complexity of the signal compared to that of SE with various noises, discriminated NSR and AF on single-lead ECG, and precisely identified the pivot points of ex vivo rotors by providing better contrast between the rotor core and the peripheral region. The improved MSE technique can provide efficient complexity analysis of variety of nonlinear and nonstationary short-time biomedical signals.
Robust Discrimination of Normal Sinus Rhythm and Atrial Fibrillation on ECG Using a Multiscale Frequency Technique

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3302

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia affecting approximately 3 million Americans, and is a prognostic marker for stroke, heart failure and even death [1]. 12-lead electrocardiogram (ECG) is used to monitor normal sinus rhythm (NSR) and also detect AF. Although the persistent form of AF can be detected relatively easy, detecting paroxysmal AF is often a challenge since requiring continuous monitoring, which becomes expensive and cumbersome to collect lot of ECG data [1]. Several researchers have attempted to develop new methods to discriminate NSR and AF which are based on R-R interval analysis, linear methods, filtering, spectral analysis, statistical approaches such as entropy etc. which faces limitation of successfully detecting AF of all types with high sensitivity and specificity using short time ECG data [1–3]. The major issues with these approaches is that they often distort the ECG by several pre-processing steps with filters, do not provide reliable discrimination using short ECG time series data and many of them lack real-time capability that makes it difficult to trust the data for diagnosis and treatment. Both clinical and scientific communities recognize these difficulties and the necessity to develop novel methods that can enable accurate monitoring and detection of AF [2]. In addition, robust detection and classification algorithms are essential for delivering appropriate therapy for implantable cardioverter defibrillators (ICD) to provide lifesaving timely action. In this work, the authors propose and demonstrate the application of a multiscale frequency (MSF) approach [4] for accurate detection and discrimination between AF and NSR ECG traces taken from publically available Physionet database. The MSF approach takes into account the contribution from various frequencies in ECG and thus yield valuable information regarding the chaotic nature of AF. Therefore, we demonstrate that MSF can capture the complexity of AF which is associated with higher MSF value compared with NSR thus enabling robust discrimination e AF manifests itself with numerous chaotic frequencies within the body surface ECG,. We validate the feasibility of this technique to discriminate NSR from AF.
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures

Circulation | October 18, 2017 | Volume: 137 | Issue: 1 | Pages: 24-33

10.1161/circulationaha.117.030523 | PMID 29046320

Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Response by Mulpuru and Shen to Letter Regarding Article, “Selective Modulation of the Cardiac Autonomic Nervous System: A New Strategy for Treatment of Cardioinhibitory Syncope”

Circulation: Arrhythmia and Electrophysiology | July 14, 2017 | Volume: 10 | Issue: 7 | Pages: No page available

10.1161/circep.117.005523 | PMID 28705879

Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 | PMID 28543771

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Selective Modulation of the Cardiac Autonomic Nervous System

Circulation: Arrhythmia and Electrophysiology | February 15, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.117.004994 | PMID 28202632

Incidence of Idiopathic Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 | PMID 28183845

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Electrograms and Marker Delay: Is There a Problem?

Pacing and Clinical Electrophysiology | February 2, 2017 | Volume: 40 | Issue: 4 | Pages: 438-441

10.1111/pace.13029 | PMID 28150317

Effect of Ventricular Arrhythmia Ablation in Patients With Heart Mate II Left Ventricular Assist Devices: An Evaluation of Ablation Therapy

Journal of Cardiovascular Electrophysiology | October 21, 2016 | Volume: 28 | Issue: 1 | Pages: 68-77

10.1111/jce.13114 | PMID 27766717

VT Ablation in LVAD RecipientsBackgroundPatients with advanced heart failure (HF) are predisposed to ventricular arrhythmias (VAs), particularly following implantation of a left ventricular assist device (LVAD). There is minimal evidence for appropriate management strategies.ObjectivesThis study aimed to compare the burden of VA and response to ablation performed either before or following LVAD implantation.MethodsWe created a retrospective cohort of patients who underwent both VA ablation and Heart Mate II (Thoratec, Pleasanton, CA, USA) LVAD implantation at Mayo Clinic (Rochester, MN, USA). Patients were stratified based on whether they underwent VA ablation before (pre‐LVAD) or after LVAD (post‐LVAD) implantation. Descriptive analyses assessed 6‐month arrhythmia burden in relation to LVAD implantation and VA ablation.ResultsA total of 9 patients underwent both LVAD implantation and VA ablation. There were 3 and 6 patients, respectively, in the pre‐LVAD and post‐LVAD cohorts. Among patients in the pre‐LVAD cohort, the median number of VAs tended to increase after ablation (9 vs. 72) and decreased after LVAD implantation (72 vs. 63). Similarly among patients in the post‐LVAD cohort, the median burden of VAs increased after LVAD implantation (1 vs. 22) and the median burden decreased after ablation (22 vs. 13). Two of 6 patients had substrate related to the LVAD inflow cannula site, while other substrate was not related directly to the cannula.ConclusionsIn patients with progressive HF and LVAD implantation, ablation is associated with reduced VA rates. In LVAD patients, most VAs arise from substrate unrelated to the inflow cannula site.
Acute Sinus Node Dysfunction after Atrial Ablation: Incidence, Risk Factors, and Management

Pacing and Clinical Electrophysiology | August 17, 2016 | Volume: 39 | Issue: 10 | Pages: 1116-1125

10.1111/pace.12934 | PMID 27530090

BackgroundMany patients with atrial fibrillation (AF) or atrial flutter (Aflutter) have concomitant sinus node dysfunction (SND). Ablation may result in injury to the sinus node complex or its blood supply resulting in sinus arrest and need for temporary pacing. We sought to characterize patients who develop acute SND (ASND) during/immediately after AF/Aflutter ablation.MethodsWe performed a retrospective analysis of AF/Aflutter ablation patients between January 1, 2010 and February 28, 2015 to characterize those who required temporary pacemaker (TPM) implantation due to ASND (sinus arrest, sinus bradycardia <40 beats/min, or junctional rhythm with hemodynamic compromise) following atrial ablation.ResultsOf 2,151 patients, eight patients (<0.5%) with ASND manifesting as sinus arrest (n = 2), severe sinus bradycardia (n = 2), and junctional rhythm with hemodynamic compromise (n = 4) were identified (all male, age 66 ± 9.9 years, 4/8 [50%] persistent AF). AF ablation was performed in four, atypical Aflutter in one, and AF/Aflutter in three patients. The ablation set consisted of: pulmonary vein (PV) isolation (n = 6), roof line ablation (n = 6), mitral annulus‐left inferior PV line ablation (n = 5), left atrial appendage‐mitral annulus ablation (n = 1), cavotricuspid isthmus ablation (n = 5), and isolation or ablation near the superior vena cava (SVC, n = 4). Patients with peri‐SVC ablation were more likely to develop ASND (P = 0.03). All patients received TPM; six received permanent pacemaker before discharge, performed 3.5 days postablation (range 2–6 days). At 3‐month device interrogation, all patients were atrially paced >50%.ConclusionASND is a rare complication of atrial ablation. It may be more common when peri‐SVC ablation is performed and may necessitate permanent pacemaker implantation.