Back to Authors

Deshmukh, Abhishek J

0000-0002-9560-1102

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 61

Anatomical location of leadless pacemaker and the risk of pacing‐induced cardiomyopathy

Journal of Cardiovascular Electrophysiology | May 10, 2023 | Volume: 34 | Issue: 6 | Pages: 1418-1426

10.1111/jce.15925 | PMID 37161942

Abstract Background It is unclear if the location of implantation of the leadless pacemaker (LP) makes a difference in the incidence of pacing‐induced cardiomyopathy (PICM). Aim The aim of this study was to compare the incidence of PICM based on the location of implantation of LP. Methods A total of 358 consecutive patients [women: 171 (48%), mean age: 73 ± 15 years] with left ventricular ejection fraction (EF) > 50%, who received an LP (Micra) between January 2017 and June 2022, formed the study cohort. Micra‐AV and Micra‐VR were implanted in 122 (34%) and 236 (66%) patients, respectively. Fluoroscopically, the location of implantation of LP in the interventricular septum (IS) was divided into two equal halves (apex/apical septum [AS] and mid/high septum [HS]). During follow‐up, PICM was defined as an EF drop of ≥10%. Results LP was implanted in 109 (34%) and 249 (66%) patients at AS and HS locations, respectively. During a mean 18 ± 8 months follow‐up, 28 patients (7.8%) developed PICM. Among the 249 patients with HS placement of LP, 10 (4%) developed PICM, whereas among the 109 patients with AS placement of LP, 18 (16.5%) developed PICM ( p = .002). AS location was associated with a higher risk of PICM compared to HS locations (adjusted hazard ratio: 4.42, p < .001). Conclusion AS location of LP was associated with a higher risk of PICM compared to HS placement. Larger randomized studies are needed to confirm our findings.
Same‐day discharge for left atrial appendage occlusion procedure: A systematic review and meta‐analysis

Journal of Cardiovascular Electrophysiology | May 2, 2023 | Volume: 34 | Issue: 5 | Pages: 1196-1205

10.1111/jce.15914 | PMID 37130436

AbstractIntroductionMost patients undergoing a left atrial appendage occlusion (LAAO) procedure are admitted for overnight observation. A same‐day discharge strategy offers the opportunity to improve resource utilization without compromising patient safety. We compared the patient safety outcomes and post‐discharge complications between same‐day discharge versus hospital admission (HA) (>1 day) in patients undergoing LAAO procedure.MethodsA systematic search of MEDLINE and Embase was conducted. Outcomes of interest included peri‐procedural complications, re‐admissions, discharge complications including major bleeding and vascular complications, ischemic stroke, all‐cause mortality, and peri‐device leak >5 mm. Mantel–Haenszel risk ratios (RRs) with 95% CIs were calculated.ResultsA total of seven observational studies met the inclusion criteria. There was no statistically significant difference between same‐day discharge versus HA regarding readmission (RR: 0.61; 95% confidence interval [CI]: [0.29–1.31]; p = .21), ischemic stroke after discharge (RR: 1.16; 95% CI: [0.49–2.73]), peri‐device leak >5 mm (RR: 1.27; 95% CI: [0.42–3.85], and all‐cause mortality (RR: 0.60; 95% CI: [0.36–1.02]). The same‐day discharge study group had significantly lower major bleeding or vascular complications (RR: 0.71; 95% CI: [0.54–0.94]).ConclusionsThis meta‐analysis of seven observational studies showed no significant difference in patient safety outcomes and post‐discharge complications between same‐day discharge versus HA. These findings provide a solid basis to perform a randomized control trial to eliminate any potential confounders.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation

Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available

10.1161/circep.122.011365 | PMID 37082954

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
New atrial arrhythmia occurrence in single chamber implantable cardioverter defibrillator patients: A real‐world investigation

Journal of Cardiovascular Electrophysiology | December 29, 2022 | Volume: 34 | Issue: 2 | Pages: 438-444

10.1111/jce.15790 | PMID 36579406

AbstractIntroductionA current limitation of single chamber implantable cardioverter defibrillators (ICDs) is the lack of an atrial lead to reliably detect atrial fibrillation (AF) episodes. A novel ventricular based atrial fibrillation (VBAF) detection algorithm was created for single chamber ICDs to assess R‐R variability for detection of AF.MethodsPatients implanted with Visia AF™ ICDs were prospectively enrolled in the Medtronic Product Surveillance Registry from December 15, 2015 to January 23, 2019 and followed with at least 30 days of monitoring with the algorithm. Time to device‐detected daily burden of AF ≥ 6 min, ≥6 h, and ≥23 h were reported. Clinical actions after device‐detected AF were recorded.ResultsA total of 291 patients were enrolled with a mean follow‐up of 22.5 ± 7.9 months. Of these, 212 (73%) had no prior history of AF at device implant. However, 38% of these individuals had AF detected with the VBAF algorithm with daily burden of ≥6 min within two years of implant. In these 80 patients with newly detected AF by their ICD, 23 (29%) had a confirmed clinical diagnosis of AF by their provider. Of patients with a clinical diagnosis of AF, nine (39%) were newly placed on anticoagulation, including five of five (100%) patients having a burden >23 h.ConclusionsContinuous AF monitoring with the new VBAF algorithm permits early identification and actionable treatment for patients with undiagnosed AF that may improve patient outcomes.
Cardiac magnetic resonance imaging is a promising modality for left atrial appendage occlusion planning

Journal of Cardiovascular Electrophysiology | October 27, 2022 | Volume: 33 | Issue: 12 | Pages: 2651-2652

10.1111/jce.15721 | PMID 36300697

The scenic route: dilated left superior intercostal vein following acute left brachiocephalic venous obstruction

EP Europace | September 15, 2022 | Volume: 25 | Issue: 1 | Pages: 39-39

10.1093/europace/euac120 | PMID 36106678

Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction

Circulation: Arrhythmia and Electrophysiology | September 8, 2022 | Volume: 15 | Issue: 9 | Pages: No page available

10.1161/circep.122.011088 | PMID 36074649

Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
Frequency of Arrhythmias and Postural Orthostatic Tachycardia Syndrome in Patients With Marfan Syndrome: A Nationwide Inpatient Study

Journal of the American Heart Association | August 24, 2022 | Volume: 11 | Issue: 17 | Pages: No page available

10.1161/jaha.121.024939 | PMID 36000435

Background Marfan syndrome (MFS) is an autosomal dominant connective tissue disorder affecting multiple systems, particularly the cardiovascular system. The leading causes of death in MFS are aortopathies and valvular disease. We wanted to identify the frequency of arrhythmia and postural orthostatic tachycardia syndrome, length of hospital stay, health care–associated costs (HAC), and in‐hospital mortality in patients with MFS. Methods and Results The National Inpatient Sample database from 2005 to 2014 was queried using International Classification of Diseases, Ninth Revision, Clinical Modification ( ICD‐9‐CM ) codes for MFS and arrhythmias. Patients were classified into subgroups: supraventricular tachycardia, ventricular tachycardia (VT), atrial fibrillation, atrial flutter, and without any type of arrhythmia. Data about length of stay, HAC, and in‐hospital mortality were also abstracted from National Inpatient Sample database. Adjusted HAC was calculated as multiplying HAC and cost‐to‐charge ratio; 12 079 MFS hospitalizations were identified; 1893 patients (15.7%) had an arrhythmia; and 4.9% of the patients had postural orthostatic tachycardia syndrome. Median values of length of stay and adjusted HAC in VT group were the highest among the groups (VT: 6 days, $18 975.8; supraventricular tachycardia: 4 days, $11 906.6; atrial flutter: 4 days, $11 274.5; atrial fibrillation: 5 days, $10431.4; without any type of arrhythmia: 4 days, $8336.6; both P =0.0001). VT group had highest in‐patient mortality (VT: 5.3%, atrial fibrillation: 4.1%, without any type of arrhythmia: 2.1%, atrial flutter: 1.7%, supraventricular tachycardia: 0%; P <0.0001) even after adjustment for potential confounders (without any type of arrhythmia versus VT; odds ratio [95% CI]: 3.18 [1.62–6.24], P =0.001). Conclusions Arrhythmias and postural orthostatic tachycardia syndrome in MFS were high and associated with increased length of stay, HAC, and in‐hospital mortality especially in patients with VT.
Cardiac resynchronization therapy response in cardiac sarcoidosis

Journal of Cardiovascular Electrophysiology | July 23, 2022 | Volume: 33 | Issue: 9 | Pages: 2072-2080

10.1111/jce.15631 | PMID 35870183

AbstractIntroductionCardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS.ObjectiveTo determine if CRT improved cardiac remodeling in patients with CS.MethodsWe retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed.ResultsOur cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT‐D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT‐P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end‐diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow‐up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died.ConclusionsOur findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.