Citations 44

Improved noise reduction in photon-counting detector CT using prior knowledge-aware iterative denoising neural network

Journal of Medical Imaging | May 24, 2024 | Volume: 11 | Issue: S1 | Pages: No page available

10.1117/1.jmi.11.s1.s12804 | PMID 38799270

Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis

Radiology | December 5, 2023 | Volume: 309 | Issue: 3 | Pages: No page available

10.1148/radiol.230853 | PMID 38051190

Ex vivo coronary calcium volume quantification using a high-spatial-resolution clinical photon-counting-detector computed tomography

Journal of Medical Imaging | July 4, 2023 | Volume: 10 | Issue: 04 | Pages: No page available

10.1117/1.jmi.10.4.043501 | PMID 37408984

High-resolution computed tomography angiography of the orbit using a photon-counting computed tomography scanner

Interventional Neuroradiology | July 4, 2023 | Volume: 31 | Issue: 4 | Pages: 539-554

10.1177/15910199231175198 | PMID 37401156

Background and Purpose Recent introduction of photon counting detector (PCD) computed tomography (CT) scanners into clinical practice further improve CT angiography (CTA) depiction of orbital arterial vasculature compared to conventional energy integrating detector (EID) CT scanners. PCD-CTA of the orbit can provide a detailed arterial roadmap of the orbit which can de diagnostic on its own or serve as a helpful planning adjunct for both diagnostic and therapeutic catheter-based angiography of the orbit. Methods For this review, EID and PCD-CT imaging was obtained in 28 volunteers. The volume CT dose index was closely matched. A dual-energy scanning protocol was used on EID-CT. An ultra-high-resolution (UHR) scan mode was used on PCD-CT. Images were reconstructed at 0.6 mm slice thickness using a closely matched medium-sharp standard resolution (SR) kernel. High-resolution (HR) images with the sharpest quantitative kernel were also reconstructed on PCD-CT at the thinnest slice thickness of 0.2 mm. A denoising algorithm was applied to the HR image series. Results The imaging description of the orbital vascular anatomy presented in this work was derived from these patients’ PCD-CTA images in combination with review of the literature. We found that orbital arterial anatomy is much better depicted with PCD-CTA, and this work can serve primarily as an imaging atlas of the normal orbital vascular anatomy. Conclusion With recent advances in technology, arterial anatomy of the orbit is much better depicted with PCD-CTA as opposed to EID-CTA. Current orbital PCD-CTA technology approaches the necessary resolution threshold for reliable evaluation of central retinal artery occlusion.
Three-dimensional printing accuracy analysis for medical applications across a wide variety of printers

Journal of Medical Imaging | April 3, 2023 | Volume: 10 | Issue: 02 | Pages: No page available

10.1117/1.jmi.10.2.026501 | PMID 37020530

Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT

Journal of Medical Imaging | February 6, 2023 | Volume: 10 | Issue: 01 | Pages: No page available

10.1117/1.jmi.10.1.016001 | PMID 36778671

Dynamic CT Angiography in Vascular Imaging: Principles and Applications

RadioGraphics | September 30, 2022 | Volume: 42 | Issue: 7 | Pages: E224-E225

10.1148/rg.210177 | PMID 36178805

Individualized and generalized models for predicting observer performance on liver metastasis detection using CT

Journal of Medical Imaging | September 13, 2022 | Volume: 9 | Issue: 05 | Pages: No page available

10.1117/1.jmi.9.5.055501 | PMID 36120413

Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma

Radiology | September 6, 2022 | Volume: 306 | Issue: 1 | Pages: 229-236

10.1148/radiol.220311 | PMID 36066364

Photon-Counting Detector CT: Key Points Radiologists Should Know

Korean Journal of Radiology | August 10, 2022 | Volume: 23 | Issue: 9 | Pages: 854

10.3348/kjr.2022.0377 | PMID 36047540