Back to Authors

Kapa, Suraj

0000-0003-2283-4340

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 36

Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope

European Heart Journal - Digital Health | May 23, 2022 | Volume: 3 | Issue: 3 | Pages: 373-379

10.1093/ehjdh/ztac030 | PMID 36712160

Abstract Aims Electrocardiogram (ECG)-enabled stethoscope (ECG-Scope) acquires a single-lead ECGs during cardiac auscultation and may facilitate real-time screening for pathologies not routinely identified by cardiac auscultation alone. We previously demonstrated an artificial intelligence (AI) algorithm can identify left ventricular dysfunction (LVSD) [defined as ejection fraction (EF) ≤ 40%] with an area under the curve (AUC) of 0.91 using a 12-lead ECG. Methods and results One hundred patients referred for clinically indicated echocardiography were prospectively recruited. ECG-Scope recordings with the patient supine and sitting were obtained in multiple electrode locations at the time of the echocardiogram. The AI algorithm for the detection of LVSD was retrained using single leads from ECG-12 and validated against ECG-Scope to determine accuracy for low EF detection (≤35%, <40%, or <50%). We evaluated the algorithm with respect to body position and lead location. Amongst 100 patients (aged 61.3 ± 13.8; 61% male, BMI: 30.0 ± 5.4), eight had EF≤40%, and six had EF 40–50%. The best single recording position was V2 with the patient supine [AUC: 0.88 (CI: 0.80–0.97) for EF≤35%, 0.85 (CI: 0.75–0.95) for EF≤40%, and 0.81 (CI: 0.71–0.90) for EF < 50%]. When using an AI model to select the recording automatically, AUC was 0.91 (CI: 0.84–0.97) for EF≤35%, 0.89 (CI: 0.83–0.96) for EF≤40%, and 0.84 (CI: 0.73–0.94) for EF < 50%. Conclusion An AI algorithm applied to an ECG-enabled stethoscope recording in standard auscultation positions reliably detected the presence of a low EF in this prospective study of patients referred for echocardiography. The ability to screen patients with a possible low EF during routine physical examination may facilitate rapid detection of LVSD.
Real-world performance, long-term efficacy, and absence of bias in the artificial intelligence enhanced electrocardiogram to detect left ventricular systolic dysfunction

European Heart Journal - Digital Health | May 17, 2022 | Volume: 3 | Issue: 2 | Pages: 238-244

10.1093/ehjdh/ztac028 | PMID 36247412

Abstract Aims Some artificial intelligence models applied in medical practice require ongoing retraining, introduce unintended racial bias, or have variable performance among different subgroups of patients. We assessed the real-world performance of the artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction with respect to multiple patient and electrocardiogram variables to determine the algorithm’s long-term efficacy and potential bias in the absence of retraining. Methods and results Electrocardiograms acquired in 2019 at Mayo Clinic in Minnesota, Arizona, and Florida with an echocardiogram performed within 14 days were analyzed (n = 44 986 unique patients). The area under the curve (AUC) was calculated to evaluate performance of the algorithm among age groups, racial and ethnic groups, patient encounter location, electrocardiogram features, and over time. The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction had an AUC of 0.903 for the total cohort. Time series analysis of the model validated its temporal stability. Areas under the curve were similar for all racial and ethnic groups (0.90–0.92) with minimal performance difference between sexes. Patients with a ‘normal sinus rhythm’ electrocardiogram (n = 37 047) exhibited an AUC of 0.91. All other electrocardiogram features had areas under the curve between 0.79 and 0.91, with the lowest performance occurring in the left bundle branch block group (0.79). Conclusion The artificial intelligence-enhanced electrocardiogram to detect left ventricular systolic dysfunction is stable over time in the absence of retraining and robust with respect to multiple variables including time, patient race, and electrocardiogram features.
Artificial intelligence—electrocardiography to detect atrial fibrillation: trend of probability before and after the first episode

European Heart Journal - Digital Health | May 9, 2022 | Volume: 3 | Issue: 2 | Pages: 228-235

10.1093/ehjdh/ztac023 | PMID 36713006

Abstract Aims Artificial intelligence (AI) enabled electrocardiography (ECG) can detect latent atrial fibrillation (AF) in patients with sinus rhythm (SR). However, the change of AI-ECG probability before and after the first AF episode is not well characterized. We sought to characterize the temporal trend of AI-ECG AF probability around the first episode of AF. Methods and results We retrospectively studied adults who had at least one ECG in SR prior to an ECG that documented AF. An AI network calculated the AF probability from ECGs during SR (positive defined >8.7%, based on optimal sensitivity and specificity). The AI-ECG probability was reported prior to and after the first episode of AF and stratified by age and CHA2DS2-VASc score. Mixed effect models were used to assess the rate of change between time points. A total of 59 212 patients with 544 330 ECGs prior to AF and 413 486 ECGs after AF were included. The mean time between the first positive AI-ECG and first AF was 5.4 ± 5.7 years. The mean AI-ECG probability was 19.8% 2–5 years prior to AF, 23.6% 1–2 years prior to AF, 34.0% 0–3 months prior to AF, 40.9% 0–3 months after AF, 35.2% 1–2 years after AF, and 42.2% 2–5 years after AF (P < 0.001). The rate of increase prior to AF was higher for age >50 years CHA2DS2-VASc score ≥4. Conclusion The AI-ECG probability progressively increases with time prior to the first AF episode, transiently decreases 1–2 years following AF and continues to increase thereafter.
Detection of Left Atrial Myopathy Using Artificial Intelligence–Enabled Electrocardiography

Circulation: Heart Failure | December 16, 2021 | Volume: 15 | Issue: 1 | Pages: No page available

10.1161/circheartfailure.120.008176 | PMID 34911362

Background: Left atrial (LA) myopathy is common in patients with heart failure and preserved ejection fraction and leads to the development of atrial fibrillation (AF). We investigated whether the likelihood of LA remodeling, LA dysfunction, altered hemodynamics, and risk for incident AF could be identified from a single 12-lead ECG using a novel artificial intelligence (AI)-enabled ECG analysis. Methods: Patients with heart failure and preserved ejection fraction (n=613) underwent AI-enabled ECG analysis, echocardiography, and cardiac catheterization. Individuals were grouped by AI-enabled ECG probability of contemporaneous AF, taken as an indicator of underlying LA myopathy. Results: Structural heart disease was more severe in patients with higher AI-probability of AF, with more left ventricular hypertrophy, larger LA volumes, and lower LA reservoir and booster strain. Cardiac filling pressures and pulmonary artery pressures were higher in patients with higher AI-probability, while cardiac output reserve was more impaired during exercise. Among patients with sinus rhythm and no prior AF, each 10% increase in AI-probability was associated with a 31% greater risk of developing new-onset AF (hazard ratio, 1.31 [95% CI, 1.20–1.42]; P <0.001). In the population as a whole, each 10% increase in AI-probability was associated with a 12% greater risk of death (hazard ratio, 1.12 [95% CI, 1.08–1.17]; P <0.001) during long-term follow-up, which was no longer significant after adjustments for baseline characteristics. Conclusions: A novel AI-enabled score derived from a single 12-lead ECG identifies the presence of underlying LA myopathy in patients with heart failure and preserved ejection fraction as evidenced by structural, functional, and hemodynamic abnormalities, as well as long-term risk for incident AF. Further research is required to determine the role of the AI-enabled ECG in the evaluation and care of patients with heart failure and preserved ejection fraction.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 | PMID 34911151

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 | PMID 34664765

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Coronary Microvascular Dysfunction and the Risk of Atrial Fibrillation From an Artificial Intelligence-Enabled Electrocardiogram

Circulation: Arrhythmia and Electrophysiology | August 16, 2021 | Volume: 14 | Issue: 8 | Pages: No page available

10.1161/circep.121.009947 | PMID 34397262

Electrogram‐guided endomyocardial biopsy yield in patients with suspected cardiac sarcoidosis and relation to outcomes

Journal of Cardiovascular Electrophysiology | July 27, 2021 | Volume: 32 | Issue: 9 | Pages: 2486-2495

10.1111/jce.15191 | PMID 34314091

AbstractObjectiveEndomyocardial biopsy (EMB) is a useful diagnostic tool though the yield may be limited in many myocardial diseases. Data on the diagnostic yield and prognostic significance of EMB guided by abnormal electrograms (EGM‐Bx) in suspected cardiac sarcoidosis (CS) are scarce.MethodsSeventy‐nine patients (mean age: 56 ± 12 years; 61% men) with suspected CS based on clinical and imaging features underwent right or left ventricular EGM‐Bx guided by electroanatomic mapping. Tissue samples were obtained from sites with abnormal EGMs and/or abnormal cardiac imaging. The diagnostic yield of EGM‐Bx was evaluated in reference to histopathologic analysis. Left ventricular assist device (LVAD) and transplantation‐free survival were compared between patients with positive and negative EGM‐Bx for CS.ResultsA total of 254 samples were obtained from abnormal EGM sites, and 126 samples from normal EGM sites guided by pre‐procedure imaging findings. Abnormal histopathology was noted in 65 (26%) and 10 (8%) samples from abnormal and normal EGM sites, respectively. Histopathology confirmed CS in 16 (20%) patients, while an alternative tissue diagnosis emerged in 10 (13%) patients. Abnormal EGMs at the biopsy site had sensitivity 89% and specificity 33% for a histopathologic diagnosis of CS. LVAD and transplantation‐free survival were not significantly associated with the EGM‐Bx result (log‐rank p = .91).ConclusionIn patients with suspected CS, abnormal EGM‐Bx has high sensitivity and low specificity for establishing a definite CS diagnosis. Consideration of substrate abnormalities apparent on preprocedural imaging as an adjunct for selection of biopsy sites may further improve EGM‐Bx yield.
Local impedance‐guided radiofrequency ablation with standard and high power: Results of a preclinical investigation

Journal of Cardiovascular Electrophysiology | July 5, 2021 | Volume: 32 | Issue: 8 | Pages: 2060-2068

10.1111/jce.15135 | PMID 34223691

AbstractBackgroundLocal impedance (LI) drop measured with microfidelity electrodes embedded in the tip of an ablation catheter accurately reflects tissue heating during radiofrequency (RF) ablation. Previous studies found 15–30 Ω LI drops created successful lesions, while more than 40 Ω drops were associated with steam pops. The objective of this study was to evaluate the safety and efficacy of LI‐guided ablation using standard (30 W) and high‐power (50 W) in a preclinical model.MethodsRF lesions were created in explanted swine hearts (n = 6) to assess the feasibility of LI‐guided ablation by targeting 10, 20, or 30 Ω (n = 20/group) drops. Subsequently, LI‐guided ablation was evaluated in a chronic animal model (n = 8 Canines, 25–29 kg, 30/50 W). During the index procedure point‐by‐point intercaval line ablation and left inferior pulmonary vein (PV) isolation were performed. RF duration was at the operators’ discretion but discontinued early if a 15–30 Ω drop was achieved. Operators attempted to avoid LI drops of more than 40 Ω. At 1‐month, durable conduction block was evaluated with electroanatomic mapping followed by necropsy and histopathology.ResultsIn explanted tissue, terminating ablation at 10, 20, or 30 Ω LI drops created statistically larger lesions (p < .05; 1.8 [1.6–2.4] mm, 3.3 [3.0–3.7] mm; 4.9 [4.3–5.5] mm). LI‐guided high‐power ablation in vivo significantly reduced RF duration per application compared to standard‐power (p < .05; intercaval: 8.9 ± 5.2 vs. 18.1 ± 11.0 s, PV: 9.6 ± 5.4 vs. 23.2 ± 10.3 s). LI drops of 15–40 Ω were more readily achievable for high‐power (90.1%, 318/353) than standard‐power (71.7%, 243/339). All intercaval lines and PV isolations were durable (16/16) at 1‐month. Necropsy revealed no major collateral injury to the pericardium, phrenic nerve, esophagus, or lungs. There was no pericardial effusion, stroke, tamponade, or PV stenosis. Vagal nerve injury was found in two 30 W animals after using 19.7 ± 13.9 and 19.5 ± 11.8 s RF applications.ConclusionLI‐guided ablation was found to be safe and efficacious in a chronic animal model. High‐power ablation more readily achieved more than 15 Ω drops, reduced RF duration compared with standard‐power, and had no major RF collateral injury.
Characteristics and Outcomes of Ventricular Tachycardia and Premature Ventricular Contractions Ablation in Patients with Prior Mitral Valve Surgery

No container title available | July 2, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162524921.19356960/v1

Background: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following MVS is limited.) CA can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. Objective: To investigate the characteristics, safety, and outcomes of radiofrequency catheter ablation (CA) in patients with prior mitral valve surgery (MVS) and ventricular arrhythmias (VA). Methods: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013- December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. Results: In our cohort of 31 patients (77% men, mean age 62.3±10.8 years, left ventricular ejection fraction 39.2±13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in 1patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Clinical VA substrates involved the peri-mitral area in 6 patients with VT and 5 patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. Conclusion: CA of VAs can be performed safely and effectively in patients with MVS