Citations 122

Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 | PMID 25097026

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.
Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory

Journal of Clinical Microbiology | May 15, 2014 | Volume: 52 | Issue: 7 | Pages: 2689-2693

10.1128/jcm.00430-14 | PMID 24829247

ABSTRACT Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved.
Inhibition Controls for Qualitative Real-Time PCR Assays: Are They Necessary for All Specimen Matrices?

Journal of Clinical Microbiology | April 16, 2014 | Volume: 52 | Issue: 6 | Pages: 2139-2143

10.1128/jcm.03389-13 | PMID 24740078

ABSTRACT A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Comparison of a Transplant Multiplex Viral Panel on the ICEPlex System with Real-Time PCR for Detection of Cytomegalovirus, Epstein-Barr Virus, and BK Virus in Clinical Specimens

Journal of Clinical Microbiology | February 20, 2014 | Volume: 52 | Issue: 5 | Pages: 1711-1713

10.1128/jcm.00358-14 | PMID 24554746

ABSTRACT We compared a multiplex viral transplant panel on the ICEPlex system to real-time PCR for the detection of cytomegalovirus (CMV), Epstein-Barr virus (EBV), and BK virus (BKV). The sensitivities of the ICEPlex were 83.3%, 95.5%, and 65.5% for the detection of CMV, EBV, and BKV, respectively. Interestingly, the multiplex assay detected dual infections in 16/280 (5.7%) samples tested.
Diagnosis of Prosthetic Joint Infection by Use of PCR-Electrospray Ionization Mass Spectrometry

Journal of Clinical Microbiology | November 28, 2013 | Volume: 52 | Issue: 2 | Pages: 642-649

10.1128/jcm.03217-13 | PMID 24478503

ABSTRACT We compared PCR-electrospray ionization mass spectrometry (PCR-ESI/MS) to culture using sonicate fluid from 431 subjects with explanted knee ( n = 270) or hip ( n = 161) prostheses. Of these, 152 and 279 subjects had prosthetic joint infection (PJI) and aseptic failure, respectively. The sensitivities for detecting PJI were 77.6% for PCR-ESI/MS and 69.7% for culture ( P = 0.0105). The specificities were 93.5 and 99.3%, respectively ( P = 0.0002).
Rapid and Direct Real-Time Detection of bla KPC and bla NDM from Surveillance Samples

Journal of Clinical Microbiology | August 22, 2013 | Volume: 51 | Issue: 11 | Pages: 3609-3615

10.1128/jcm.01731-13 | PMID 23966498

ABSTRACT We assessed the performance of a duplex real-time PCR assay for bla KPC and bla NDM performed directly (D-PCR) on perianal and perirectal swabs and stool. Spiked specimens and 126 clinical surveillance swabs (comprising a sensitivity panel of 46 perirectal double swabs previously determined to be culture positive for bla KPC -PCR-positive Enterobacteriaceae and a specificity panel of 80 perianal swabs from patients at risk of carbapenemase-producing Enterobacteriaceae [CPE] colonization) were studied. For the surveillance swabs, D-PCR was compared to PCR after broth enrichment (BE-PCR) and two culture-based methods: the HardyCHROM ESBL agar (HC-A) and the CDC screening (CDC-A) methods. PCR was performed on morphologically distinct colonies that were isolated by culture. All of the initial PCR testing was done without extraction using a simple lysis procedure. The analytical sensitivities of D-PCR for bla KPC were 9 CFU/μl (for swabs) and 90 CFU/μl (for stool), and for bla NDM , it was 1.9 CFU/μl (for both swabs and stool). In the clinical sensitivity panel, D-PCR and BE-PCR were initially positive for bla KPC in 41/46 (89.1%) and 43/46 (93.5%) swabs, respectively. The swabs that were initially negative by D-PCR ( n = 5) and BE-PCR ( n = 3) were visibly stool soiled; all swabs were bla KPC positive upon repeat testing after lysate extraction. The CDC-A and HC-A yielded bla KPC -positive Enterobacteriaceae from 36/46 (78.3%) and 35/46 (76.1%) swabs, respectively (sensitivities of D-PCR/BE-PCR postextraction of soiled specimens versus HC-A, P = 0.0009, and versus CDC-A, P = 0.0016). All swabs in the specificity panel were negative for CPE by all four methods. D-PCR allows for the timely detection of bla KPC and bla NDM carriage with excellent sensitivity when specimens visibly soiled with stool undergo preparatory extraction.
Microbial Biofilms and Breast Tissue Expanders

BioMed Research International | July 16, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/254940 | PMID 23956974

We previously developed and validated a vortexing-sonication technique for detection of biofilm bacteria on the surface of explanted prosthetic joints. Herein, we evaluated this technique for diagnosis of infected breast tissue expanders and used it to assess colonization of breast tissue expanders. From April 2008 to December 2011, we studied 328 breast tissue expanders at Mayo Clinic, Rochester, MN, USA. Of seven clinically infected breast tissue expanders, six (85.7%) had positive cultures, one of which grewPropionibacteriumspecies. Fifty-two of 321 breast tissue expanders (16.2%, 95% CI, 12.3–20.7%) without clinical evidence of infection also had positive cultures, 45 growingPropionibacteriumspecies and ten coagulase-negative staphylococci. While vortexing-sonication can detect clinically infected breast tissue expanders, 16 percent of breast tissue expanders appear to be asymptomatically colonized with normal skin flora, most commonly,Propionibacteriumspecies.
Comparison of a Novel, Rapid Chromogenic Biochemical Assay, the Carba NP Test, with the Modified Hodge Test for Detection of Carbapenemase-Producing Gram-Negative Bacilli

Journal of Clinical Microbiology | July 4, 2013 | Volume: 51 | Issue: 9 | Pages: 3097-3101

10.1128/jcm.00965-13 | PMID 23824767

ABSTRACT We compared carbapenemase detection among 271 Gram-negative bacilli (of which 131 were carbapenemase producers) using a novel chromogenic rapid test—the Carba NP test (CNP)—and the modified Hodge test (MHT). Sensitivities were comparable (CNP, 100%, versus MHT, 98%; P = 0.08), but CNP was more specific (100% versus 80%; P < 0.0001) and faster.
Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

Journal of Clinical Microbiology | May 9, 2013 | Volume: 51 | Issue: 7 | Pages: 2280-2287

10.1128/jcm.00335-13 | PMID 23658273

ABSTRACT We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee ( n = 272) or hip ( n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture ( P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.
Rapid PCR Detection of Mycoplasma hominis, Ureaplasma urealyticum, and Ureaplasma parvum

International Journal of Bacteriology | March 11, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-7

10.1155/2013/168742 | PMID 26904723

Objective. We compared laboratory developed real-time PCR assays for detection of Mycoplasma hominis and for detection and differentiation of Ureaplasma urealyticum and parvum to culture using genitourinary specimens submitted for M. hominis and Ureaplasma culture. Methods. 283 genitourinary specimens received in the clinical bacteriology laboratory for M. hominis and Ureaplasma species culture were evaluated. Nucleic acids were extracted using the Total Nucleic Acid Kit on the MagNA Pure 2.0. 5 μL of the extracts were combined with 15 μL of each of the two master mixes. Assays were performed on the LightCycler 480 II system. Culture was performed using routine methods. Results. M. hominis PCR detected 38/42 M. hominis culture-positive specimens, as well as 2 that were culture negative (sensitivity, 90.5%; specificity, 99.2%). Ureaplasma PCR detected 139/144 Ureaplasma culture-positive specimens, as well as 9 that were culture negative (sensitivity, 96.5%; specificity, 93.6%). Of the specimens that tested positive for Ureaplasma species, U. urealyticum alone was detected in 33, U. parvum alone in 109, and both in 6. Conclusion. The described PCR assays are rapid alternatives to culture for detection of M. hominis and Ureaplasma species, and, unlike culture, the Ureaplasma assay easily distinguishes U. urealyticum from parvum.