Citations 122

Dual-Energy CT Iodine-Subtraction Virtual Unenhanced Technique to Detect Urinary Stones in an Iodine-Filled Collecting System: A Phantom Study

American Journal of Roentgenology | April 22, 2008 | Volume: 190 | Issue: 5 | Pages: 1169-1173

10.2214/ajr.07.3154 | PMID 18430827

The Mayo Classification System for Traumatic Brain Injury Severity

Journal of Neurotrauma | September 24, 2007 | Volume: 24 | Issue: 9 | Pages: 1417-1424

10.1089/neu.2006.0245 | PMID 17892404

Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on Clinical Laboratory Operations

Journal of Clinical Microbiology | July 19, 2007 | Volume: 45 | Issue: 9 | Pages: 3101-3104

10.1128/jcm.00656-07 | PMID 17634308

ABSTRACT The COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (CAP/CA), and the COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5, were compared. CAP/CA reduced and consolidated labor while modestly increasing assay throughput without increased failure rates or direct costs, regardless of batch size and assay format.
MRI Findings of 26 Patients with Parsonage-Turner Syndrome

American Journal of Roentgenology | June 19, 2007 | Volume: 189 | Issue: 1 | Pages: W39-W44

10.2214/ajr.06.1136 | PMID 17579134

Relative Risk of Mortality after Traumatic Brain Injury: A Population-Based Study of The Role of Age And Injury Severity

Journal of Neurotrauma | April 2, 2007 | Volume: 24 | Issue: 3 | Pages: 435-445

10.1089/neu.2006.0119 | PMID 17402850

Effect of referral bias on assessing survival in ALS

Neurology | February 19, 2007 | Volume: 68 | Issue: 8 | Pages: 600-602

10.1212/01.wnl.0000254501.58158.e7 | PMID 17310031

Incidence and outcome of cervical artery dissection

Neurology | November 27, 2006 | Volume: 67 | Issue: 10 | Pages: 1809-1812

10.1212/01.wnl.0000244486.30455.71 | PMID 17130413

Patient Outcomes After Vestibular Schwannoma Management: a Prospective Comparison of Microsurgical Resection and Stereotactic Radiosurgery

Neurosurgery | July 6, 2006 | Volume: 59 | Issue: 1 | Pages: 77-85

10.1227/01.neu.0000219217.14930.14 | PMID 16823303

Quantification of Hepatitis B Virus (HBV) DNA with a TaqMan HBV Analyte-Specific Reagent following Sample Processing with the MagNA Pure LC Instrument

Journal of Clinical Microbiology | April 6, 2006 | Volume: 44 | Issue: 4 | Pages: 1490-1494

10.1128/jcm.44.4.1490-1494.2006 | PMID 16597881

ABSTRACT TaqMan hepatitis B virus (HBV) analyte-specific reagent (ASR; Roche Molecular Systems, Inc., Branchburg, NJ) is designed for the quantification of HBV DNA in serum or plasma. The performance characteristics of TaqMan HBV ASR following automated sample processing with the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, IN) were evaluated in this study. Analytical sensitivity and precision were assessed with commercially available HBV standards, while clinical serum specimens from HBsAg-seropositive patients and healthy blood donors were used to determine clinical sensitivity, specificity, and correlation with other commercially available assays. Analytical studies yielded a limit of detection of 2.4 IU/ml, with good linearity and correlation ( R 2 = 0.9958) with expected HBV DNA titers over a wide range (6.0 × 10 0 to 2.1 × 10 8 IU/ml). Clinical sensitivity and specificity of the assay combined with automated sample processing were both 100%. Comparison of TaqMan HBV ASR and VERSANT HBV DNA 3.0 assay (bDNA; Bayer HealthCare LLC, Tarrytown, NY) results among clinical specimens yielded good correlation ( R 2 = 0.9237), with a mean difference in titer of −0.213 log 10 IU/ml (95% confidence interval, −0.678 to 1.10 log 10 IU/ml). The overall test failure rate was 2.0% among 204 clinical serum specimens tested. Total time required for MP sample processing and automated postelution handling of 24 samples was 224 min, with 57 min of actual hands-on time. MP is a reliable, labor-saving platform suitable for use with TaqMan HBV ASR, providing sensitive and accurate quantification of HBV DNA levels over a range of 8 log 10 IU/ml.
Comparison of Specimen Processing and Nucleic Acid Extraction by the Swab Extraction Tube System versus the MagNA Pure LC System for Laboratory Diagnosis of Herpes Simplex Virus Infections by LightCycler PCR

Journal of Clinical Microbiology | March 4, 2005 | Volume: 43 | Issue: 3 | Pages: 1059-1063

10.1128/jcm.43.3.1059-1063.2005 | PMID 15750060

ABSTRACT A total of 563 specimens (234 dermal and 329 genital swabs) from patients suspected of having herpes simplex virus (HSV) infections were processed using two different extraction methods (the MagNA Pure LC system and the swab extraction tube system [SETS]); HSV DNA was amplified by LightCycler PCR. HSV DNA was detected in 157 of 563 specimens (27.9%) processed by the MagNA Pure LC system and in 179 of 563 specimens (31.8%) processed by SETS ( P < 0.0001). There was no specimen processed by the MagNA Pure LC extraction method that was positive only for HSV DNA. Of 157 specimens positive by both methods, HSV DNA copy levels were higher (using cycle crossover points [cycle threshold { C T }]) with SETS (mean C T , 25.9 cycles) than with the MagNA Pure LC system (mean C T , 32.0 cycles) ( P < 0.0001). The time to process 32 samples was longer with the MagNA Pure LC extraction system (90 min) than with SETS (35 min). HSV DNA extraction using SETS is faster, less expensive, and more sensitive than the MagNA Pure LC system and could replace the latter for the laboratory diagnosis of HSV infections using LightCycler PCR.