Back to Authors

Manduca, A

0000-0002-9411-5671

Mayo Clinic

Physiology and Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, Minnesota, USA.

Citations 16

Wavelet MRE: Imaging propagating broadband acoustic waves with wavelet‐based motion‐encoding gradients

Magnetic Resonance in Medicine | December 15, 2023 | Volume: 91 | Issue: 5 | Pages: 1923-1935

10.1002/mrm.29972 | PMID 38098427

AbstractPurposeTo demonstrate a novel MR elastography (MRE) technique, termed here wavelet MRE. With this technique, broadband motion sensitivity is achievable. Moreover, the true tissue displacement can be reconstructed with a simple inverse transform.MethodsA wavelet MRE sequence was developed with motion‐encoding gradients based on Haar wavelets. From the phase images' displacement was estimated using an inverse transform. Simulations were performed using a frequency sweep and a transient as ground‐truth motions. A PVC phantom was scanned using wavelet MRE and standard MRE with both transient (one and 10 cycles of 90‐Hz motion) and steady‐state dual‐frequency motion (30 and 60 Hz) for comparison. The technique was tested in a human brain, and motion trajectories were estimated for each voxel.ResultsIn simulation, the displacement information estimated from wavelet MRE closely matched the true motion. In the phantom test, the MRE phase data generated from the displacement information derived from wavelet MRE agreed well with standard MRE data. Testing of wavelet MRE to assess transient motion waveforms in the brain was successful, and the tissue motion observed was consistent with a previous study.ConclusionThe uniform and broadband frequency response of wavelet MRE makes it a promising method for imaging transient, multifrequency motion, or motion with unknown frequency content. One potential application is measuring the response of brain tissue undergoing low‐amplitude, transient vibrations as a model for the study of traumatic brain injury.
Head-to-head comparison of magnetic resonance elastography-based liver stiffness, fat fraction, and T1 relaxation time in identifying at-risk NASH

Hepatology | April 20, 2023 | Volume: 78 | Issue: 4 | Pages: 1200-1208

10.1097/hep.0000000000000417 | PMID 37080558

Background and Aims: The presence of at-risk NASH is associated with an increased risk of cirrhosis and complications. Therefore, noninvasive identification of at-risk NASH with an accurate biomarker is a critical need for pharmacologic therapy. We aim to explore the performance of several magnetic resonance (MR)-based imaging parameters in diagnosing at-risk NASH. Approach and Results: This prospective clinical trial (NCT02565446) includes 104 paired MR examinations and liver biopsies performed in patients with suspected or diagnosed NAFLD. Magnetic resonance elastography-assessed liver stiffness (LS), 6-point Dixon-derived proton density fat fraction (PDFF), and single-point saturation-recovery acquisition-calculated T1 relaxation time were explored. Among all predictors, LS showed the significantly highest accuracy in diagnosing at-risk NASH [AUCLS: 0.89 (0.82, 0.95), AUCPDFF: 0.70 (0.58, 0.81), AUCT1: 0.72 (0.61, 0.82), z-score test z >1.96 for LS vs any of others]. The optimal cutoff value of LS to identify at-risk NASH patients was 3.3 kPa (sensitivity: 79%, specificity: 82%, negative predictive value: 91%), whereas the optimal cutoff value of T1 was 850 ms (sensitivity: 75%, specificity: 63%, and negative predictive value: 87%). PDFF had the highest performance in diagnosing NASH with any fibrosis stage [AUCPDFF: 0.82 (0.72, 0.91), AUCLS: 0.73 (0.63, 0.84), AUCT1: 0.72 (0.61, 0.83), |z| <1.96 for all]. Conclusion: Magnetic resonance elastography-assessed LS alone outperformed PDFF, and T1 in identifying patients with at-risk NASH for therapeutic trials.
Impact of material homogeneity assumption on cortical stiffness estimates by MR elastography

Magnetic Resonance in Medicine | April 5, 2022 | Volume: 88 | Issue: 2 | Pages: 916-929

10.1002/mrm.29226 | PMID 35381121

PurposeInversion algorithms used to convert acquired MR elastography wave data into material property estimates often assume that the underlying materials are locally homogeneous. Here we evaluate the impact of that assumption on stiffness estimates in gray‐matter regions of interest in brain MR elastography.MethodsWe describe an updated neural network inversion framework using finite‐difference model–derived data to train convolutional neural network inversion algorithms. Neural network inversions trained on homogeneous simulations (homogeneous learned inversions [HLIs]) or inhomogeneous simulations (inhomogeneous learned inversions [ILIs]) are generated with a variety of kernel sizes. These inversions are evaluated in a brain MR elastography simulation experiment and in vivo in a test–retest repeatability experiment including 10 healthy volunteers.ResultsIn simulation and in vivo, HLI and ILI with small kernels produce similar results. As kernel size increases, the assumption of homogeneity has a larger effect, and HLI and ILI stiffness estimates show larger differences. At each inversion's optimal kernel size in simulation (7 × 7 × 7 for HLI, 11 × 11 × 11 for ILI), ILI is more sensitive to true changes in stiffness in gray‐matter regions of interest in simulation. In vivo, there is no difference in the region‐level repeatability of stiffness estimates between the inversions, although ILI appears to better maintain the stiffness map structure as kernel size increases, while decreasing the spatial variance in stiffness estimates.ConclusionsThis study suggests that inhomogeneous inversions provide small but significant benefits even when large stiffness gradients are absent.
MR elastography: Principles, guidelines, and terminology

Magnetic Resonance in Medicine | December 10, 2020 | Volume: 85 | Issue: 5 | Pages: 2377-2390

10.1002/mrm.28627 | PMID 33296103

Magnetic resonance elastography (MRE) is a phase contrast–based MRI technique that can measure displacement due to propagating mechanical waves, from which material properties such as shear modulus can be calculated. Magnetic resonance elastography can be thought of as quantitative, noninvasive palpation. It is increasing in clinical importance, has become widespread in the diagnosis and staging of liver fibrosis, and additional clinical applications are being explored. However, publications have reported MRE results using many different parameters, acquisition techniques, processing methods, and varied nomenclature. The diversity of terminology can lead to confusion (particularly among clinicians) about the meaning of and interpretation of MRE results. This paper was written by the MRE Guidelines Committee, a group formalized at the first meeting of the ISMRM MRE Study Group, to clarify and move toward standardization of MRE nomenclature. The purpose of this paper is to (1) explain MRE terminology and concepts to those not familiar with them, (2) define “good practices” for practitioners of MRE, and (3) identify opportunities to standardize terminology, to avoid confusion.
TURBINE‐MRE: A 3D hybrid radial‐Cartesian EPI acquisition for MR elastography

Magnetic Resonance in Medicine | August 1, 2020 | Volume: 85 | Issue: 2 | Pages: 945-952

10.1002/mrm.28445 | PMID 32738084

PurposeTo develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain.MethodThe proposed 3D TURBINE‐MRE is based on a spoiled gradient‐echo MRE sequence with the EPI readout radially rotating about the phase‐encoding axis to sample a full 3D k‐space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32‐channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin‐echo (SE) EPI‐MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE‐MRE images were off‐line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE‐EPI‐MRE and TURBINE‐MRE.ResultsThe 3D wave‐field images and the generated stiffness maps were comparable between TURBINE‐MRE and standard SE‐EPI‐MRE for the phantom and the volunteers. The Bland–Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943.ConclusionWe demonstrated the feasibility of the new TURBINE‐MRE sequence for acquiring the desired 3D wave‐field data and stiffness maps in a phantom and in‐vivo brains. This pilot study encourages further exploration of TURBINE‐MRE for functional MRE, free‐breathing abdominal MRE, and cardiac MRE applications.
Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.