Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 | PMID 35763435

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
Atrial Arrhythmia Ablation in Patients With D-Transposition of the Great Arteries and Atrial Switch

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010546 | PMID 35763440

Background: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. Methods: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. Results: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation ( P <0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. Conclusions: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 | PMID 35233867

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Cardiac ablation with pulsed electric fields: principles and biophysics

EP Europace | February 25, 2022 | Volume: 24 | Issue: 8 | Pages: 1213-1222

10.1093/europace/euac033 | PMID 35426908

Abstract Pulsed electric fields (PEFs) have emerged as an ideal cardiac ablation modality. At present numerous clinical trials in humans are exploring PEF as an ablation strategy for both atrial and ventricular arrhythmias, with early data showing significant promise. As this is a relatively new technology there is limited understanding of its principles and biophysics. Importantly, PEF biophysics and principles are starkly different to current energy modalities (radiofrequency and cryoballoon). Given the relatively novel nature of PEFs, this review aims to provide an understanding of the principles and biophysics of PEF ablation. The goal is to enhance academic research and ultimately enable optimization of ablation parameters to maximize procedure success and minimize risk.
Targeted ablation of gastric pacemaker sites to modulate patterns of bioelectrical slow wave activation and propagation in an anesthetized pig model

American Journal of Physiology-Gastrointestinal and Liver Physiology | February 9, 2022 | Volume: 322 | Issue: 4 | Pages: G431-G445

10.1152/ajpgi.00332.2021 | PMID 35137624

This study presents gastric ablation as a novel tool for modulating gastric bioelectrical activation, including eliminating the normal gastric pacemaker site as well as abnormal ectopic pacemaker sites underlying gastric dysrhythmias. Targeted application of radiofrequency ablation was able to eliminate these pacemaker sites without disrupting surrounding conduction capability or tissue structure. Gastric ablation presents a powerful new research tool for modulating gastric electrical activation and may likely hold therapeutic potential for disorders of gastric function.
Time in therapeutic range of anticoagulation among patients with atrial fibrillation and cerebral amyloid angiopathy

Baylor University Medical Center Proceedings | December 28, 2021 | Volume: 35 | Issue: 2 | Pages: 162-167

10.1080/08998280.2021.2013393 | PMID 35261442

Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 | PMID 34911151

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 | PMID 34664765

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.
Regional and Temporal Variation of Ventricular and Conduction Tissue Activity During Ventricular Fibrillation in Canines

Circulation: Arrhythmia and Electrophysiology | September 27, 2021 | Volume: 14 | Issue: 10 | Pages: No page available

10.1161/circep.121.010281 | PMID 34665643

Background: Rigorous study of ventricular fibrillation (VF) is not feasible in humans. The spatiotemporal characteristics of prolonged VF remain undefined, limiting our understanding of this lethal rhythm. Methods: VF was mapped in 4 canines. The endocardial and epicardial left ventricle (LV) and right ventricle (RV) were sequentially mapped at 0 to 15, 15 to 30, 30 to 45, and 45 to 60 minutes post-induction. Ten consecutive beats were used to determine the average cycle length and regularity index of ventricular and His-Purkinje system signals in discrete regions during each time interval. Results: Average VF time was 58±12 minutes. The shortest ventricular cycle length was present in the RV apical region (70±10 msec) at 0 to 15 minutes and at 15 to 30 minutes (89±31 msec) and LV apical region at 45 to 60 minutes (242±163 msec). The His-Purkinje system cycle length was the shortest at the RV outflow tract (75±3 msec) at 0 to 15 minutes, RV inflow and free wall (89±12 msec) at 15 to 30 minutes, LV apical region (83±14 msec) at 30 to 45 minutes, and inferior and inferolateral LV (145±23 msec) at 45 to 60 minutes. Regularity index was the highest in the RV inflow and free wall (78%) at 0 to 15 minutes, RV apical region (86%) at 15 to 30 minutes, LV septum and epicardial anterior RV (80%) at 30 to 45 minutes, and anterior and anterolateral LV (75%) at 45 to 60 minutes. Conclusions: These data suggest significant regional changes in electrical activity throughout VF in canines. A transition of fastest electrical activity from RV to LV apical regions across VF was observed. These novel insights of the temporal and spatial changes of VF merit further evaluation in diseased hearts to assess for reproducibility of findings.
Automatic wide complex tachycardia differentiation using mathematically synthesized vectorcardiogram signals

Annals of Noninvasive Electrocardiology | September 25, 2021 | Volume: 27 | Issue: 1 | Pages: No page available

10.1111/anec.12890 | PMID 34562325

AbstractBackgroundAutomated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification.MethodsA derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one “all‐inclusive” model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance.ResultsThe VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X‐lead QRS amplitude change, Y‐lead QRS amplitude change, and Z‐lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95).ConclusionCustom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.