Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Effect of Long-Term Right Ventricular Pacing in Young Adults With Structurally Normal Heart

Circulation | April 5, 2010 | Volume: 121 | Issue: 15 | Pages: 1698-1705

10.1161/circulationaha.109.866343 | PMID 20368525

Background— Right ventricular pacing increases the risk of heart failure in adults with structural heart disease. The impact of prolonged right ventricular pacing in adults without structural heart disease is not fully characterized and may depend on interactions of pacing with abnormal substrate predisposing to ventricular dysfunction. Methods and Results— We assessed the effect of right ventricular pacing in patients who underwent pacemaker implantation for isolated congenital atrioventricular block between 1964 and 2005. To assess for immunologic contribution to cardiac dysfunction, outcomes were compared between patients with (Ab + ) and without (Ab − ) antinuclear antibody during adulthood and an age- and sex-matched Olmsted County, Minnesota, population. Of 103 patients (mean±SD age, 32±19 years), 18 were Ab + . Long-term survival free of new heart failure after pacemaker implantation in isolated congenital atrioventricular block patients was worse than in the matched population ( P <0.001). This difference was attributable to the development of heart failure in 12 Ab + patients (67%; P <0.001), without differences between Ab − patients (2%) and the matched population (2%; P =0.7). Compared with baseline, at last follow-up, left ventricular ejection fraction did not decline in Ab − (53±9% to 57±12%) but decreased in Ab + (52±10% to 38±12%; P =0.03) patients. Survival was similar in Ab − patients and the Minnesota population (98%; P =0.7) but worse in Ab + patients (79%; P <0.01). Conclusions— The natural history of patients with isolated congenital atrioventricular block who require pacing depends upon their antibody status. Antinuclear antibody status was a predictor for the development of heart failure and death. Long-term right ventricular pacing alone does not appear to be associated with development of heart failure, deterioration in ventricular function, or reduced survival in Ab − isolated congenital atrioventricular block patients.
Tachycardia and the AV Nodal Region

Circulation: Arrhythmia and Electrophysiology | February 16, 2010 | Volume: 3 | Issue: 1 | Pages: 2-6

10.1161/circep.110.937144 | PMID 20160175

Managing Atrial Fibrillation

Circulation: Arrhythmia and Electrophysiology | December 16, 2009 | Volume: 2 | Issue: 6 | Pages: 599-602

10.1161/circep.109.922674 | PMID 20009073

Atrial Fibrillation: Focal or Reentrant or Both?

Circulation: Arrhythmia and Electrophysiology | August 18, 2009 | Volume: 2 | Issue: 4 | Pages: 345-348

10.1161/circep.109.888081 | PMID 19808489

Supravalvular Arrhythmia

Circulation: Arrhythmia and Electrophysiology | June 16, 2009 | Volume: 2 | Issue: 3 | Pages: 316-326

10.1161/circep.108.847962 | PMID 19808482

Mechanisms and Utility of Discrete Great Arterial Potentials in the Ablation of Outflow Tract Ventricular Arrhythmias

Circulation: Arrhythmia and Electrophysiology | June 5, 2008 | Volume: 1 | Issue: 1 | Pages: 30-38

10.1161/circep.107.750315 | PMID 19808391

Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Catheter Ablation for Atrial Fibrillation in Patients With Obesity

Circulation | May 13, 2008 | Volume: 117 | Issue: 20 | Pages: 2583-2590

10.1161/circulationaha.107.716712 | PMID 18474813

Background— Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results— Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped by body mass index (lean, <25 kg/m 2 ; overweight, 25 to 29.9 kg/m 2 ; obese, ≥30 kg/m 2 ). Outcome and quality of life were measured with a general health survey (Medical Outcomes Study 36-item Short-Form General Health Survey [SF-36]); patients were assessed before ablation and at 3 and 12 months after the procedure. Two hundred twenty-eight study patients (44%) were overweight, and 201 (38%) were obese. Twelve months after curative ablation, 72% of patients were free of atrial fibrillation without the use of antiarrhythmic agents; 84% were arrhythmia free when those receiving medication were included. Atrial fibrillation was eliminated in 75%, 72%, and 70% of the lean, overweight, and obese patients, respectively, at 12 months ( P =0.41, trend test). SF-36 scores were lower for patients with higher body mass index ( P <0.05) at baseline. SF-36 scores improved in every functional domain for all body mass index groups after ablation. The mean SF-36 total physical score increased from 59±20 at baseline to 77±19 in 12 months ( P <0.001). The total mental health score improved from 66±18 to 79±16 in 12 months ( P <0.001). Conclusions— Catheter ablation of atrial fibrillation was effective in obese patients. Coexistence of atrial fibrillation and obesity indicated lower SF-36 scores, but the improvement in quality of life was consistent across all body mass index categories.
Ablation for Atrial Fibrillation

Circulation | November 26, 2007 | Volume: 116 | Issue: 22 | Pages: 2517-2519

10.1161/circulationaha.107.741454 | PMID 18040036

Clinical Presentation, Investigation, and Management of Pulmonary Vein Stenosis Complicating Ablation for Atrial Fibrillation

Circulation | February 7, 2005 | Volume: 111 | Issue: 5 | Pages: 546-554

10.1161/01.cir.0000154541.58478.36 | PMID 15699274

Background— Although segmental or circumferential ablation is effective in eliminating pulmonary vein (PV)–mediated atrial fibrillation (AF), this procedure may be complicated by the occurrence of PV stenosis. Methods and Results— To establish the clinical presentation, diagnostic manifestations, and interventional management of PV stenosis, 23 patients with stenosis of 34 veins complicating ablation of AF were evaluated. Each patient became symptomatic 103±100 days after undergoing ablation. In 8 veins, the ablation producing the PV stenosis was a repeated procedure for continued AF. Nineteen patients presented with dyspnea on exertion, 7 with dyspnea at rest, 9 with cough, and 6 with chest pain. On multirow spiral computed tomography examination, the narrowest lumen of the affected PVs measured 3±2 mm compared with 13±3 mm at baseline ( P ≤0.001). The relative perfusion of affected lung segments on isotope scans was reduced to 4±3% of total perfusion compared with 22±10% in unaffected segments. At percutaneous intervention, these veins showed 80±13% stenosis, with a mean gradient of 12±5 mm Hg. This was significantly reduced to a residual stenosis of 9±8% ( P ≤0.001) and a residual gradient of 3±4 mm Hg ( P ≤0.001). Twenty veins were treated with balloon dilatation alone, whereas 14 veins were stented with standard 10-mm-diameter bare-metal stents. Although the symptomatic response was nearly immediate and impressive, 14 patients developed in-stent or in-segment restenosis, requiring repeated interventions in 13. Conclusions— Percutaneous intervention produces rapid and dramatic symptom relief in patients with highly symptomatic PV stenosis after radiofrequency ablation for AF. Nevertheless, alternative treatment methods will be required to decrease recurrent in-stent or in-segment restenosis.