Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Rapid Point-of-Care Sterilization of Personal Protective Equipment for Frontline Healthcare Workers*

2025 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) | December 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: 1-5

10.1109/embc58623.2025.11253647 | PMID 41335821

Atrial and Ventricular Dyssynchrony, Cardiomyopathy, and Atrial Fibrillation: To Synchronize or to Ablate First?

Pacing and Clinical Electrophysiology | November 25, 2025 | Volume: 49 | Issue: 2 | Pages: 161-165

10.1111/pace.70095 | PMID 41288324

ABSTRACT Background Optimal management in patients presenting with persistent atrial fibrillation, cardiomyopathy, and atrial as well as ventricular dyssynchrony with left bundle branch block is unclear. Results and Methods A 67‐year‐old female patient presented with persistent atrial fibrillation, cardiomyopathy with a newly reduced ejection fraction (EF), increased P wave duration on electrocardiogram (ECG) and left bundle branch block. After shared decision making, the patient elected to proceed with Bachman bundle/left bundle branch area pacing plus atrioventricular (AV) node ablation. At 6‐month follow‐up post procedure, a repeat echocardiogram showed normalized atrial size and EF (65%). Device interrogation demonstrated no recurrent atrial fibrillation with the patient off antiarrhythmic and heart failure medical therapy. Conclusions Integrated atrial and ventricular synchronization through Bachmann bundle and left bundle branch area pacing may help break the cycle of dyssynchrony, remodeling, and arrhythmia. In combination with AV node ablation, it may be considered as an alternative treatment option in certain cases after shared decision making.
Atrioventricular node ablation for refractory atrial fibrillation in patients with hypertrophic cardiomyopathy: a case–control study

Europace | September 6, 2025 | Volume: 27 | Issue: 9 | Pages: No page available

10.1093/europace/euaf208 | PMID 40913440

Sex, Race, and Socioeconomic Disparities in the Utilization of Transvenous Lead Removal for Patients Hospitalized With Cardiac Implantable Electronic Device Infections in the United States

Journal of Cardiovascular Electrophysiology | June 12, 2025 | Volume: 36 | Issue: 8 | Pages: 1938-1947

10.1111/jce.16758 | PMID 40501006

ABSTRACT Background Transvenous lead removal (TLR) is a Class I indication for patients with cardiac implantable electronic device (CIED) infections. However, disparities in the utilization of TLR have not been fully explored, particularly concerning demographic and socioeconomic factors. Objectives This study aims to examine whether disparities exist among patients hospitalized for CIED infections with respect to the utilization of TLR, focusing on sex, race, and income characteristics. Methods We utilized the 2019 National Inpatient Sample (NIS) to assess patients hospitalized with CIED infections and identify those who underwent TLR. Multiple logistic regression was used to examine risk factors for TLR utilization, including age, sex, race/ethnicity, and socioeconomic characteristics. Results A total of 56 709 patients were hospitalized for CIED infection in the United States in 2019, of which 9867 (17.4%) underwent TLR. On an adjusted analysis, females and Black patients were found to have lower odds of undergoing TLR compared to males and White patients (OR: 0.62; 95% CI: 0.59–0.78; p < 0.01; and OR: 0.47; 95% CI: 0.39–0.57; p < 0.01, respectively). Hispanic patients also had reduced odds of TLR (OR: 0.73; 95% CI: 0.58–0.93; p = 0.01). No significant associations were observed between income or insurance status and the likelihood of receiving TLR after adjustment. Conclusions This study identified significant disparities in the utilization of TLR among patients hospitalized for CIED infections. Female, Black, and Hispanic patients were significantly less likely to receive TLR.
Atrioventricular Dyssynchrony and Dyspnea in Heart Failure With Preserved Ejection Fraction

Circulation: Heart Failure | May 19, 2025 | Volume: 18 | Issue: 7 | Pages: No page available

10.1161/circheartfailure.125.013183 | PMID 40384453

Cardiac function after catheter ablation of ventricular arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy

European Heart Journal Open | May 5, 2025 | Volume: 5 | Issue: 3 | Pages: No page available

10.1093/ehjopen/oeaf049 | PMID 40458289

Abstract Aims Catheter ablation is commonly performed in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) for management of ventricular arrhythmias (VAs). The impact of catheter ablation on cardiac function is unknown. The aim is to assess the impact of catheter ablation for VAs on cardiac function in patients with ARVC. Methods and results This retrospective study included consecutive patients with ARVC who underwent catheter ablation for VAs. Cardiac and valvular functions were assessed on pre- and post-procedure cardiac imaging. The severities of tricuspid regurgitation, pulmonic regurgitation, right ventricular (RV) enlargement, and RV systolic dysfunction was graded as absent (=0), mild (=1), mild-moderate (=2), moderate (=3), moderate-severe (=4), or severe (=5). Thirty-four patients were included. Median age at the time of ablation was 49 [inter-quartile range (IQR), 23] years, and 10 (29%) patients were female. After a median follow-up of 1 (IQR, 0) day, 11 (34%) patients had worsening RV function, and 4 (12%) patients had worsening left ventricular ejection fraction (LVEF) &gt;5%. Five (15%) patients required inotropic support. After a median follow-up of 6.5 (IQR, 6.4) months, 20 (59%) patients had repeat transthoracic echocardiograms. Among patients with worsening RV function post-ablation, one-sixth (17%) had improvement in the RV function at follow-up. In contrast, among patients who had an acute drop in LVEF post-ablation, two-thirds (67%) had improvement at follow-up. Conclusion Right ventricular dysfunction following catheter ablation in patients with ARVC is common, affecting one-third of patients. Patients undergoing catheter ablation of VAs should be counselled on the potential negative impact of ablation on cardiac function.
Outcomes in Patients With Mitral Annular Disjunction and an Implantable‐Cardioverter Defibrillator

Journal of Cardiovascular Electrophysiology | March 18, 2025 | Volume: 36 | Issue: 5 | Pages: 1014-1021

10.1111/jce.16612 | PMID 40098314

ABSTRACT Background Mitral annular disjunction (MAD) carries an increased risk of complex ventricular arrhythmias, which can lead to sudden cardiac death. Many of these patients undergo implantable cardioverter defibrillator (ICD) implantation, but their ICD outcomes are not known. Objective The aim of this study was to assess the outcomes of ICD implantation and the predictors of appropriate ICD therapies in patients with MAD. Methods The study included patients with MAD who underwent ICD implantation. Clinical, electrocardiographic, cardiac imaging, and device therapy data were collected. Results Forty‐nine patients with MAD and ICD were included. Median age was 49 (21) years, and 29 (59%) were female. 13 (27%) patients underwent ICD implantation for primary prevention and 36 (73%) patients for secondary prevention. Over a median follow‐up of 27.3 (35.3) months, 23 (47%) patients received ICD therapies. 18 (37%) patients had appropriate ICD therapies, and 5 (10%) patients had inappropriate ICD shocks. Median time to first appropriate therapy was 22.3 (63.3) months. In patients with a secondary prevention ICD indication, the rate of appropriate ICD therapies was 44%, while in patients with a primary prevention ICD indication, it was 15%. Among patients with appropriate ICD therapies, the first therapies were delivered for monomorphic ventricular tachycardia (VT) in 7 (39%) patients and polymorphic VT or ventricular fibrillation (VF) in 11 (61%) patients. Patients with appropriate ICD therapies were more likely to have a history of SCA ( p = 0.003) and/or low left ventricular ejection fraction (LVEF) ( p = 0.022) before ICD implantation as compared to patients without appropriate ICD therapies. Conclusions In our cohort of patients with MAD and ICD, appropriate ICD therapies were common. Most appropriate ICD therapies were delivered for polymorphic VT or VF. Larger studies are needed to elucidate the mechanisms of VAs and refine risk stratification in MAD.
Effects of In Vivo Contact Force on Pulsed‐Field Ablation Efficacy in Porcine Ventricles

Journal of Cardiovascular Electrophysiology | January 24, 2025 | Volume: 36 | Issue: 3 | Pages: 642-649

10.1111/jce.16581 | PMID 39853784

ABSTRACT Background Pulsed‐field ablation (PFA) is an innovative non‐thermal method for arrhythmia treatment. The efficacy of various PFA configurations in relation to contact force (CF) has not been well‐studied in vivo. Objectives This study evaluated the effect of CF on acute bipolar PFA lesions in both a vegetal and an in vivo porcine heart model. Methods Bipolar PFA (500 V, 20 μs for 50 pulses) was applied to eight porcine ventricles, with CF categorized as standard (5–15 g), high (16–30 g), or very high (> 30 g) using the CARTO 3 system. PFA lesions were assessed by gross pathology, histology, and post‐ablation voltage amplitude. Additionally, a vegetal model using oscillating russet potatoes replicated the motion of a beating heart to compare lesion parameters under dynamic conditions and various PFA configurations (monopolar vs. bipolar). Results A total of 61 in vivo bipolar PFA lesions across all groups were analyzed. No significant differences in lesion surface diameter, depth, or volume were found among CF groups. In the vegetal model, monopolar setting had a better correlation between CF and lesion depth compared to bipolar setting. In addition, oscillations and catheter position (perpendicular or parallel) significantly affected lesion dimensions. Conclusion Increasing CF has a minimal effect on the size of acute bipolar PFA lesions in the porcine ventricle, suggesting that, for bipolar PFA, adequate CF is more critical than its intensity in a beating heart. For monopolar PFA, greater CF can impact lesion depth.
What Is the Mechanism of Atrial Fibrillation Initiation?

Circulation | December 26, 2024 | Volume: 151 | Issue: 1 | Pages: 120-122

10.1161/circulationaha.124.072920 | PMID 39723981

Detection of Right and Left Ventricular Dysfunction in Pediatric Patients Using Artificial Intelligence–Enabled ECGs

Journal of the American Heart Association | November 4, 2024 | Volume: 13 | Issue: 21 | Pages: No page available

10.1161/jaha.124.035201 | PMID 39494568

Background Early detection of left and right ventricular systolic dysfunction (LVSD and RVSD respectively) in children can lead to intervention to reduce morbidity and death. Existing artificial intelligence algorithms can identify LVSD and RVSD in adults using a 12‐lead ECG; however, its efficacy in children is uncertain. We aimed to develop novel artificial intelligence–enabled ECG algorithms for LVSD and RVSD detection in pediatric patients. Methods and Results We identified 10 142 unique pediatric patients (age≤18) with a 10‐second, 12‐lead surface ECG within 14 days of a transthoracic echocardiogram, performed between 2002 and 2022. LVSD was defined quantitatively by left ventricular ejection fraction (LVEF). RVSD was defined semiquantitatively. Novel pediatric models for LVEF ≤35% and LVEF <50% achieved excellent test areas under the curve of 0.93 (95% CI, 0.89–0.98) and 0.88 (95% CI, 0.83–0.94) respectively. The model to detect LVEF <50% had a sensitivity of 0.85, specificity of 0.80, positive predictive value of 0.095, and negative predictive value of 0.995. In comparison, the previously validated adult data‐derived model for LVEF <35% achieved an area under the curve of 0.87 (95% CI, 0.84–0.90) for LVEF ≤35% in children. A novel pediatric model for any RVSD detection reached a test area under the curve of 0.90 (0.87–0.94). Conclusions An artificial intelligence–enabled ECG demonstrates accurate detection of both LVSD and RVSD in pediatric patients. While adult‐trained models offer good performance, improvements are seen when training pediatric‐specific models.