Back to Authors

El Sabbagh, Abdallah

0000-0003-3250-1312

Mayo Clinic

Department of Cardiovascular Disease (S.M.G., A.E.S., G.E.L., P.M.P., D.P.P.), Mayo Clinic, Jacksonville, FL.

Citations 15

30‐day patient reported outcomes can be predicted by change in left atrial pressure and not change in transmitral gradient following MitraClip

Catheterization and Cardiovascular Interventions | January 27, 2021 | Volume: 97 | Issue: 6 | Pages: 1244-1249

10.1002/ccd.29477 | PMID 33502087

AbstractBackgroundChange in left atrial pressure (LAP) has been shown to be associated with symptom improvement post‐MitraClip; however, the association between acute procedural changes in transmitral diastolic mean gradient (MG) compared to LAP and symptom improvement is not well established.Methods164 consecutive patients undergoing MitraClip at Mayo Clinic between June 2014 and May 2018 were included. Preclip and postclip MG and LAP were recorded. Baseline demographics, clinical, and echocardiographic outcomes, including 30‐day New York Heart Association (NYHA) functional status were obtained from patient charts.ResultsMedian age was 81.5 years (IQR: 76.3, 87), 34% were female and 94.5% had NYHA class III and IV functional status at baseline. At baseline, median MG was 4 mmHg (IQR: 3, 5) and LAP was 19 mmHg (IQR: 16, 23.5). Following MitraClip deployment, the median MG was 4 mmHg (IQR: 3, 6) and the median LAP was 17 mmHg (IQR: 14, 21), 69.5% of patients had less than moderate MR. There was no statistically significant association between change in MG and NYHA functional class at 30 days (OR = 0.95, 95% CI: 0.76–1.20). However, a reduction in LAP following MitraClip deployment was significantly associated with improvement in NYHA functional status at 30 days following adjustments for age and sex (aOR 3.36, 95% CI: 1.34–8.65). There was no significant correlation between change in mean LAP and change in MG (p = .98).ConclusionUnlike change in left atrial pressure, change in MG post‐MitraClip was not associated with patient reported outcomes at 30 days and did not correlate with change in left atrial pressure. Long‐term follow up is needed to evaluate the impact of LA pressure on symptoms.
Endovascular snare technique to facilitate delivery of self‐expanding valve during transcatheter aortic valve‐in‐valve replacement in angulated aortas: A case series

Catheterization and Cardiovascular Interventions | January 15, 2021 | Volume: 97 | Issue: 4 | Pages: 736-742

10.1002/ccd.29459 | PMID 33427384

AbstractBackgroundTranscatheter aortic valve‐in‐valve replacement (ViV) has been widely accepted as a less invasive alternative to treat failed aortic surgical or transcatheter bioprosthetic valves. Angulated aortas present an additional challenge, particularly when using self‐expanding transcatheter heart valves (SE‐THV).MethodsTwo patients with failed surgical bioprosthetic aortic valves and one patient with a failed transcatheter bioprosthetic aortic valve underwent transcatheter aortic ViV using SE‐THV. All were deemed high‐risk for surgical aortic valve replacement by a heart team. All three patients had initial failed SE‐THV delivery using a conventional approach with subsequent successful delivery using the endovascular snare technique.ResultsIn Cases 1 and 2, the SE‐THV was biased towards the greater curve of the angulated aorta and behind the outer frame of the bioprosthetic valve frame. An endovascular snare was deployed through a secondary left femoral artery access, and the valve delivery system was advanced through the snare in the ascending aorta. The snare was tightened around the SE‐THV capsule proximal to the hat‐marker, allowing deflection of the SE‐THV and successful delivery. In Case 3, the SE‐THV interacted with the tall frame of a failed SE‐THV. A snare via the left femoral artery was deployed in the descending artery. The SE‐THV was advanced through the snare, and both the snare and SE‐THV were advanced together to the ascending aorta where the SE‐THV was deflected and successfully delivered.ConclusionsThe endovascular snare technique is a feasible option for successful delivery of SE‐THV during transcatheter aortic ViV in failed transcatheter or surgical bioprosthetic valves in angulated aortas.
Paravalvular leak repair after balloon‐expandable transcatheter mitral valve implantation in mitral annular calcification: Early experience and lessons learned

Catheterization and Cardiovascular Interventions | February 9, 2019 | Volume: 94 | Issue: 5 | Pages: 764-772

10.1002/ccd.28131 | PMID 30737972

AbstractBackgroundTreatment of hemodynamically significant mitral annular calcification (MAC) using transcatheter approaches is in the early learning phase. The occurrence of paravalvular leak (PVL) following transcatheter mitral valve in MAC is common.AimsTo report the initial experience and techniques of percutaneous PVL closure after transcatheter valve in MAC.MethodsThis series includes five consecutive patients who underwent percutaneous PVL closure following transcatheter balloon expandable SAPIEN S3 valve in MAC.ResultsMean patient age was 73.6 ± 5.4 years (4 [80%] female), with average Society of Thoracic Surgeons score of 8.1 ± 2.8%. Three patients had a single PVL defect while two patients had two defects; all were located at the commissural sites. Closure was performed primarily for heart failure in four patients and hemolytic anemia in one patient. Transfemoral transseptal antegrade approach and Amplatz Vascular Plug (AVP)‐II occluders were utilized in all patients. Procedure success was achieved in three patients. One patient developed significant occluder related leaflet impingement and subsequent severe prosthetic mitral regurgitation requiring a second transcatheter mitral valve in valve implantation. The procedure was aborted in one patient due to difficulty crossing PVL defect after balloon post‐dilatation of SAPIEN prosthesis with 10 mL of additional volume. There was no in hospital or 30 day mortality or the need for emergent surgery.ConclusionEarly experience with percutaneous PVL closure of SAPIEN valve in MAC demonstrated feasibility of this approach. Careful procedure planning and monitoring for SAPIEN prosthesis leaflet impingement and frame instability is of utmost importance to increase the chances of procedural success.
Revascularization for Left Main and Multivessel Coronary Artery Disease: Current Status and Future Prospects after the EXCEL and NOBLE Trials

Korean Circulation Journal | April 24, 2018 | Volume: 48 | Issue: 6 | Pages: 447

10.4070/kcj.2018.0078 | PMID 29856140

Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 | PMID 29359388

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.