Back to Authors

Patel, Robin

0000-0001-6344-4141

Mayo Clinic

Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA.

Citations 366

Species Identification and Antibiotic Resistance Prediction by Analysis of Whole-Genome Sequence Data by Use of ARESdb: an Analysis of Isolates from the Unyvero Lower Respiratory Tract Infection Trial

Journal of Clinical Microbiology | April 11, 2020 | Volume: 58 | Issue: 7 | Pages: No page available

10.1128/jcm.00273-20 | PMID 32295890

Whole-genome sequencing (WGS) is now routinely performed in clinical microbiology laboratories to assess isolate relatedness. With appropriately developed analytics, the same data can be used for prediction of antimicrobial susceptibility. We assessed WGS data for identification using open-source tools and antibiotic susceptibility testing (AST) prediction using ARESdb compared to matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification and broth microdilution phenotypic susceptibility testing on clinical isolates from a multicenter clinical trial of the FDA-cleared Unyvero lower respiratory tract infection (LRTI) application (Curetis).
Implant Sonication versus Tissue Culture for the Diagnosis of Spinal Implant Infection

Spine | April 10, 2020 | Volume: 45 | Issue: 9 | Pages: E525-E532

10.1097/brs.0000000000003311 | PMID 32282655

Mini We compared the sensitivity and specificity of peri-implant tissue culture to the vortexing–sonication technique for the diagnosis of spinal implant infection (SII). Lower thresholds of sonicate fluid culture positivity showed increased sensitivity with maintained specificity. We recommend a threshold of 20 CFU/10 mL for sonicate culture positivity for the diagnosis of SII. Study Design. This is a retrospective study comparing the diagnosis of spinal implant infection (SII) by peri-implant tissue culture to vortexing–sonication of retrieved spinal implants. Objective. We hypothesized that vortexing–sonication would be more sensitive than peri-implant tissue culture. Summary of Background Data. We previously showed implant vortexing–sonication followed by culture to be more sensitive than standard peri-implant tissue culture for diagnosing of SII. In this follow-up study, we analyzed the largest sample size available in the literature to compare these two culture methods and evaluated thresholds for positivity for sonicate fluid for SII diagnosis. Methods. We compared peri-implant tissue culture to the vortexing–sonication technique which samples bacterial biofilm on the surface of retrieved spinal implants. We evaluated different thresholds for sonicate fluid positivity and assessed the sensitivity and specificity of the two culture methods for the diagnosis of SII. Results. A total of 152 patients were studied. With more than 100 colony forming units (CFU)/10 mL as a threshold for sonicate fluid culture positivity, there were 46 patients with SII. The sensitivities of peri-implant tissue and sonicate fluid culture were 65.2% and 79.6%; the specificities were 88.7% and 93.4%, respectively. With more than 50 CFU/10 mL as a threshold, there were 50 patients with SII. The sensitivities of peri-implant tissue and sonicate fluid culture were 68.0% and 76.0%; the specificities were 92.2% for both methods. Finally, with more than or equal to 20 CFU/10 mL as a threshold, there were 52 patients with SII. The sensitivities of peri-implant tissue and sonicate fluid culture were 69.2% and 82.7%; the specificities were 94.0% and 92.0%, respectively. Conclusion. Implant sonication followed by culture is a sensitive and specific method for the diagnosis of SII. Lower thresholds for defining sonicate fluid culture positivity allow for increased sensitivity with a minimal decrease in specificity, enhancing the clinical utility of implant sonication. Level of Evidence: 4
Hypochlorous acid-generating electrochemical scaffold eliminates Candida albicans biofilms

Journal of Applied Microbiology | April 6, 2020 | Volume: 129 | Issue: 4 | Pages: 776-786

10.1111/jam.14656 | PMID 32249986

Abstract Aims Wound infections involving Candida albicans can be challenging to treat because of the fungus’ ability to penetrate wound tissue and form biofilms. The goal of this study was to assess the activity of a hypochlorous acid (HOCl)-generating electrochemical scaffold (e-scaffold) against C. albicans biofilms in vitro and on porcine dermal explants (ex vivo). Methods and Results C. albicans biofilms were grown either on acrylic-bottom six-well plates (in vitro) or on skin tissue excised from porcine ears (ex vivo), and the polarized e-scaffold was used to generate a continuous supply of low concentration HOCl near biofilm surfaces. C. albicans biofilms grown in vitro were reduced to undetectable amounts within 24 h of e-scaffold exposure, unlike control biofilms (5·28 ± 0·034 log10 (CFU cm-2); P < 0·0001). C. albicans biofilms grown on porcine dermal explants were also reduced to undetectable amounts in 24 h, unlike control explant biofilms (4·29 ± 0·057 log10 (CFU cm-2); P < 0·0001). There was a decrease in the number of viable mammalian cells (35·6 ± 6·4%) in uninfected porcine dermal explants exposed to continuous HOCl-generating e-scaffolds for 24 h compared to explants exposed to nonpolarized e-scaffolds (not generating HOCl) (P < 0·05). Conclusions Our HOCl-generating e-scaffold is a potential antifungal-free strategy to treat C. albicans biofilms in chronic wounds. Significance and Impact of the Study Wound infections caused by C. albicans are difficult to treat due to presence of biofilms in wound beds. Our HOCl producing e-scaffold provides a promising novel approach to treat wound infections caused by C. albicans.
Report from the American Society for Microbiology COVID-19 International Summit, 23 March 2020: Value of Diagnostic Testing for SARS–CoV-2/COVID-19

mBio | March 30, 2020 | Volume: 11 | Issue: 2 | Pages: No page available

10.1128/mbio.00722-20 | PMID 32217609

ARGONAUT II Study of the In Vitro Activity of Plazomicin against Carbapenemase-Producing Klebsiella pneumoniae

Antimicrobial Agents and Chemotherapy | March 5, 2020 | Volume: 64 | Issue: 5 | Pages: No page available

10.1128/aac.00012-20 | PMID 32152078

Plazomicin was tested against 697 recently acquired carbapenem-resistant Klebsiella pneumoniae isolates from the Great Lakes region of the United States. Plazomicin MIC 50 and MIC 90 values were 0.25 and 1 mg/liter, respectively; 680 isolates (97.6%) were susceptible (MICs of ≤2 mg/liter), 9 (1.3%) intermediate (MICs of 4 mg/liter), and 8 (1.1%) resistant (MICs of >32 mg/liter). Resistance was associated with rmtF -, rmtB -, or armA -encoded 16S rRNA methyltransferases in all except 1 isolate.
Clostridioides difficileWhole-genome Sequencing Differentiates Relapse With the Same Strain From Reinfection With a New Strain

Clinical Infectious Diseases | February 15, 2020 | Volume: 72 | Issue: 5 | Pages: 806-813

10.1093/cid/ciaa159 | PMID 32064535

AbstractBackgroundCurrent approaches in tracking Clostridioides difficile infection (CDI) and individualizing patient management are incompletely defined.MethodsWe recruited 468 subjects with CDI at Mayo Clinic Rochester between May and December 2016 and performed whole-genome sequencing (WGS) on C. difficile isolates from 397. WGS was also performed on isolates from a subset of the subjects at the time of a recurrence of infection. The sequence data were analyzed by determining core genome multilocus sequence type (cgMLST), with isolates grouped by allelic differences and the predicted ribotype.ResultsThere were no correlations between C. difficile isolates based either on cgMLST or ribotype groupings and CDI outcome. An epidemiologic assessment of hospitalized subjects harboring C. difficile isolates with ≤2 allelic differences, based on standard infection prevention and control assessment, revealed no evidence of person-to-person transmission. Interestingly, community-acquired CDI subjects in 40% of groups with ≤2 allelic differences resided within the same zip code. Among 18 subjects clinically classified as having recurrent CDI, WGS revealed 14 with initial and subsequent isolates differing by ≤2 allelic differences, suggesting a relapse of infection with the same initial strain, and 4 with isolates differing by >50 allelic differences, suggesting reinfection. Among the 5 subjects classified as having a reinfection based on the timing of recurrence, 3 had isolates with ≤2 allelic differences between them, suggesting a relapse, and 2 had isolates differing by >50 allelic differences, suggesting reinfection.ConclusionsOur findings point to potential transmission of C. difficile in the community. WGS better differentiates relapse from reinfection than do definitions based on the timing of recurrence.
16S rRNA Gene PCR/Sequencing of Cerebrospinal Fluid in the Diagnosis of Post-operative Meningitis

Access Microbiology | February 3, 2020 | Volume: 2 | Issue: 2 | Pages: No page available

10.1099/acmi.0.000100 | PMID 34568757

Introduction. Post-operative meningitis (POM) is a life-threatening complication of neurosurgery. Diagnosis is often difficult due to pre-existing inflammation and antecedent antimicrobial use. Bacterial cerebrospinal fluid (CSF) cultures may reveal no growth, but empiric antibiotics are typically given due to the high morbidity and mortality associated with POM. 16S rRNA gene PCR/sequencing is a molecular methodology that can identify the presence of bacteria regardless of viability for culture. Case Presentation. A patient presented with a rapid onset of fever associated with headache, neck pain, nausea and altered mental status 11 days after undergoing laser interstitial thermal therapy for treatment of recurrent astrocytoma at another hospital. Based on clinical presentation and imaging, POM was suspected, and empiric antibacterial therapy was started. Microbiological stains and cultures of CSF were negative. Due to persistent fevers, 16S rRNA gene PCR/sequencing was done on CSF; it detected a member of the order Enterobacteriales most closely resembling Serratia species. All antimicrobials were stopped except for cefepime, which was given for 2 weeks. The patient’s mental status fully recovered. Conclusion. The application of 16S rRNA gene PCR/sequencing in the setting of POM is of value by improving the quality of patient care and decreasing costs by antimicrobial de-escalation. Further studies regarding the positive and negative predictive values of this test are required.
Proposed Plasma Ammonia Reference Intervals in a Reference Group of Hospitalized Term and Preterm Neonates

The Journal of Applied Laboratory Medicine | January 27, 2020 | Volume: 5 | Issue: 2 | Pages: 363-369

10.1093/jalm/jfz001 | PMID 32445380

AbstractBackgroundPlasma ammonia is commonly measured in the diagnostic evaluation of hospitalized newborns, but reference values are not well defined.MethodsWe prospectively enrolled newborns admitted to the level III/IV neonatal intensive care unit and level II intermediate special care nursery from January 2017 to January 2018. Infants with inborn errors of metabolism or liver disease were excluded. Plasma ammonia concentrations were measured once within the first week of life and evaluated by sex, gestational age, timing of the draw, blood collection method, and type of nutrition. Reference intervals were calculated.Results127 neonates were included; one third (34%) were term infants born at ≥37 weeks gestation, and two thirds (66%) were born preterm at <37 weeks gestation. Median plasma ammonia concentrations were 32 μmol/L (range <10 to 86 μmol/L). Median ammonia concentrations were higher among preterm compared to term infants (35 vs. 28 μmol/L, p = 0.0119), and term female compared to term male infants (34 vs. 26 μmol/L, p = 0.0228). There was no difference in median ammonia concentrations between female and male preterm infants, based on gestational age within the preterm group, timing of the blood draw, presence of hyperbilirubinemia, blood collection method, or type of nutritional intake.ConclusionsPlasma ammonia concentrations among newborns are higher than the expected adult concentrations and may vary by gestational age and sex. Blood collection method, type of nutrition, hyperbilirubinemia, and timing of the draw do not impact concentrations. We propose a reference limit of ≤82 μmol/L for newborns less than one week of age.
Hydrogen Peroxide-Generating Electrochemical Scaffold Activity against Trispecies Biofilms

Antimicrobial Agents and Chemotherapy | January 17, 2020 | Volume: 64 | Issue: 4 | Pages: No page available

10.1128/aac.02332-19 | PMID 31964793

The antibiofilm activity of a hydrogen peroxide-generating electrochemical scaffold (e-scaffold) was determined against mono- and trispecies biofilms of methicillin-resistant Staphylococcus aureus , multidrug-resistant Pseudomonas aeruginosa , and Candida albicans . Significant time-dependent decreases were found in the overall CFU of biofilms of all three monospecies and the trispecies forms. Confocal laser scanning microscopy showed dramatic reductions in fluorescence intensities of biofilm matrix protein and polysaccharide components of e-scaffold-treated biofilms.
Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 12 | Pages: 3258-3263

10.1128/jcm.35.12.3258-3263.1997 | PMID 9399530

An evaluation was undertaken to determine the optimal method for testing the susceptibilities of 100 clinical isolates and two reference strains of Enterococcus spp. to vancomycin in vitro. Six testing methods were studied by using the following media and incubation times: agar screen with the Synergy Quad Plate (Remel, Lenexa, Kans.), an in-house-prepared brain heart infusion (BHI) agar plate, and an in-house-prepared Mueller-Hinton (MH) agar plate, all incubated for 24 or 48 h; broth microdilution (Sensititre Just One Strip; AccuMed International, Inc., West Lake, Ohio) with BHI or cation-adjusted MH broth incubated for 24 or 48 h; agar dilution with BHI or MH agar incubated for 24 or 48 h; epsilometer test (E test; AB BioDisk, Solna, Sweden) with BHI or MH agar incubated for 24 or 48 h; disk diffusion with BHI or MH agar incubated for 24 or 48 h; and the automated Vitek method with the gram-positive susceptibility Staphylococcus aureus card and R02.03 software (bioMerieux, Inc., Hazelwood, Mo.). Growth failures occurred with MH media (n = 6) but not with BHI media. One growth failure occurred with the Vitek method. Results for each testing method for each Enterococcus strain were interpreted as susceptible, intermediate, or resistant according to current National Committee for Clinical Laboratory Standards (NCCLS) criteria and compared to the vancomycin resistance genotype (i.e., vanA, vanB, vanC-1, or vanC-2/3). For all methods, extension of the incubation time from 24 h to 48 h either produced no difference in the results or gave poorer results. The following methods produced no very major or major interpretive errors: broth microdilution with BHI media incubated for 24 h, agar dilution with BHI media incubated for 24 or 48 h, and E test with BHI media incubated for 24 or 48 h. Unacceptable frequencies of very major errors (> 1%) occurred with all methods for which MH media were used. Minor interpretive errors were frequent with all methods. These minor interpretive errors also occurred most frequently with Enterococcus strains with vanC genes, which encoded low-level vancomycin resistance (MIC < or = 8 microg/ml), as opposed to Enterococcus strains which possessed vanA or vanB genes, which encoded higher-level vancomycin resistance (MIC > or = 64 microg/ml). Modification of NCCLS breakpoints, especially for motile Enterococcus spp. (E. casseliflavus, E. flavescens, and E. gallinarum), may resolve this problem; however, in the current study, one E. faecalis strain and one E. faecium strain carried only the vanC gene. The agar screen method may also require reformulation. The current agar screen plate contains 6 microg of vancomycin per ml, which may not detect all low-level resistance associated with vanC genotypes. Nevertheless, the clinical significance of this low-level vancomycin resistance remains unknown.