Citations 64

CT Colonography for the Detection of Nonpolypoid Adenomas: Sensitivity Assessed With Restricted National CT Colonography Trial Criteria

American Journal of Roentgenology | November 21, 2014 | Volume: 203 | Issue: 6 | Pages: W614-W622

10.2214/ajr.13.12356 | PMID 25415726

Comparison of manual and semiautomated techniques for analyzing gastric volumes with MRI in humans

American Journal of Physiology-Gastrointestinal and Liver Physiology | July 11, 2014 | Volume: 307 | Issue: 5 | Pages: G582-G587

10.1152/ajpgi.00048.2014 | PMID 25012844

Gastric emptying, accommodation, and motility can be quantified with magnetic resonance imaging (MRI). The first step in image analysis entails segmenting the stomach from surrounding structures, usually by a time-consuming manual process. We have developed a semiautomated process to segment and measure gastric volumes with MRI. Gastric images were acquired with a three-dimensional gradient echo MRI sequence at 5, 10, 20, and 30 min after ingestion of a liquid nutrient (Ensure, 296 ml) labeled with gadolinium in 20 healthy volunteers and 29 patients with dyspeptic symptoms. The agreement between gastric volumes measured by manual segmentation and our new semiautomated algorithm was assessed with Lin's concordance correlation coefficient (CCC) and the Bland Altman test. At 5 min after a meal, food volumes measured by manual (352 ± 4 ml) and semiautomated (346 ± 4 ml) techniques were correlated {CCC[95% confidence interval (CI)] 0.70 (0.52, 0.81)}; air volumes measured by manual (88 ± 6 ml) and semiautomated (84 ± 6 ml) techniques were also correlated [CCC (95% CI) 0.89 (0.82, 0.94)]. Findings were similar at subsequent time points. The Bland Altman test was not significant. The time required for semiautomated segmentation ranged from an average of 204 s for the 5-min images to 233 s for the 20-min images. These times were appreciably smaller than the typical times of many tens of minutes, even hours, required for manual segmentation. To conclude, a semiautomated process can measure gastric food and air volume using MRI with comparable accuracy and far better efficiency than a manual process.
Putting the Fat and Water Protons to Work for You: A Demonstration Through Clinical Cases of How Fat-Water Separation Techniques Can Benefit Your Body MRI Practice

American Journal of Roentgenology | November 21, 2013 | Volume: 201 | Issue: 6 | Pages: 1303-1308

10.2214/ajr.13.10606 | PMID 24261371

Noncathartic CT Colonography: Image Quality Assessment and Performance and in a Screening Cohort

American Journal of Roentgenology | September 24, 2013 | Volume: 201 | Issue: 4 | Pages: 787-794

10.2214/ajr.12.9225 | PMID 24059367

Individualization of Abdominopelvic CT Protocols With Lower Tube Voltage to Reduce IV Contrast Dose or Radiation Dose

American Journal of Roentgenology | June 21, 2013 | Volume: 201 | Issue: 1 | Pages: 147-153

10.2214/ajr.12.9295 | PMID 23789669

Multiphase CT Enterography Evaluation of Small-Bowel Vascular Lesions

American Journal of Roentgenology | June 21, 2013 | Volume: 201 | Issue: 1 | Pages: 65-72

10.2214/ajr.12.10414 | PMID 23789659

Prospective Assessment of Dynamic CT and MR Cholangiography in Functional Biliary Pain

American Journal of Roentgenology | May 31, 2013 | Volume: 201 | Issue: 2 | Pages: W271-W282

10.2214/ajr.12.9538 | PMID 23724800

Intraductal Papillary Mucinous Neoplasms of the Pancreas: CT Patterns of Recurrence and Multiobserver Performance in Detecting Recurrent Neoplasm After Surgical Resection

American Journal of Roentgenology | February 28, 2013 | Volume: 183 | Issue: 5 | Pages: 1367-1374

10.2214/ajr.183.5.1831367 | PMID 15505305

Preoperative Detection of Pancreatic Insulinomas on Multiphasic Helical CT

American Journal of Roentgenology | February 28, 2013 | Volume: 181 | Issue: 3 | Pages: 775-780

10.2214/ajr.181.3.1810775 | PMID 12933480

Lowering Kilovoltage to Reduce Radiation Dose in Contrast-Enhanced Abdominal CT: Initial Assessment of a Prototype Automated Kilovoltage Selection Tool

American Journal of Roentgenology | October 24, 2012 | Volume: 199 | Issue: 5 | Pages: 1070-1077

10.2214/ajr.12.8637 | PMID 23096181