Citations 297

Biological and Analytical Variability of a Novel High-Sensitivity Cardiac Troponin T Assay

Clinical Chemistry | May 15, 2010 | Volume: 56 | Issue: 7 | Pages: 1086-1090

10.1373/clinchem.2009.140616 | PMID 20472824

AbstractBackground: High-sensitivity cardiac troponin assays will augment the frequency of increased results, making important the determination of reference change values to distinguish acute from chronic increases. We assessed short- and long-term biological variability of cardiac troponin T (cTnT) in healthy subjects with a novel high-sensitivity (hs) assay.Methods: We collected blood from 20 healthy volunteers at 5 time points for short-term study and biweekly at 4 times from the same volunteers for long-term study. We analyzed serum samples in duplicate with a hscTnT assay on the Roche Modular E170 and computed reference change values (RCVs) for analytical, intraindividual, interindividual, and total change values (CVA, CVI, CVG, and CVT, respectively) and the index of individuality (II). We calculated RCVs by using a log-normal approach, owing to the skewed results of the data.Results: Short- and long-term CVA values were 53.5% and 98%. CVI and CVG were 48.2% and 85.9%, respectively, for short-term studies and 94% and 94% for long-term studies. Mean δ values for the within-day study were 58% and −57.5%, and between-day mean δ values were 103.4% and −87%. Within- and between-day IIs were 0.8 and 0.14, respectively.Conclusions: The biological variation demonstrated with the hscTnT assay is higher than prior data for cardiac troponin I. This may be attributed to differences in biology or assay imprecision at low concentrations. A short-term change (RCV log normal) of 85% and a long-term change of 315% is necessary to define a changing pattern.
Being Rational about (Im)precision: A Statement from the Biochemistry Subcommittee of the Joint European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Heart Federation Task Force for the Definition of Myoc

Clinical Chemistry | April 1, 2010 | Volume: 56 | Issue: 6 | Pages: 941-943

10.1373/clinchem.2010.143958 | PMID 20360122

Trends in Incidence, Severity, and Outcome of Hospitalized Myocardial Infarction

Circulation | February 9, 2010 | Volume: 121 | Issue: 7 | Pages: 863-869

10.1161/circulationaha.109.897249 | PMID 20142444

Background— In 2000, the definition of myocardial infarction (MI) changed to rely on troponin rather than creatine kinase (CK) and its MB fraction (CK-MB). The implications of this change on trends in MI incidence and outcome are not defined. Methods and Results— This was a community study of 2816 patients hospitalized with incident MI from 1987 to 2006 in Olmsted County, Minnesota, with prospective measurements of troponin and CK-MB from August 2000 forward. Outcomes were MI incidence, severity, and survival. After troponin was introduced, 278 (25%) of 1127 incident MIs met only troponin-based criteria. When cases meeting only troponin criteria were included, incidence did not change between 1987 and 2006. When restricted to cases defined by CK/CK-MB, the incidence of MI declined by 20%. The incidence of non–ST-segment elevation MI increased markedly by relying on troponin, whereas that of ST-segment elevation MI declined regardless of troponin. The age- and sex-adjusted hazard ratio of death within 30 days for an infarction occurring in 2006 (compared with 1987) was 0.44 (95% confidence interval, 0.30 to 0.64). Among 30-day survivors, survival did not improve, but causes of death shifted from cardiovascular to noncardiovascular ( P =0.001). Trends in long-term survival among 30-day survivors were similar regardless of troponin. Conclusions— Over the last 2 decades, a substantial change in the epidemiology of MI occurred that was only partially mediated by the introduction of troponin. Non–ST-segment elevation MIs now constitute the majority of MIs. Although the 30-day case fatality improved markedly, long-term survival did not change, and the cause of death shifted from cardiovascular to noncardiovascular.
2007 Universal Myocardial Infarction Definition Change Criteria for Risk Stratification by Use of a High-Sensitivity Cardiac Troponin I Assay

Clinical Chemistry | January 14, 2010 | Volume: 56 | Issue: 3 | Pages: 487-489

10.1373/clinchem.2009.136689 | PMID 20075178

High-Sensitivity Cardiac Troponin: Hype, Help, and Reality

Clinical Chemistry | December 30, 2009 | Volume: 56 | Issue: 3 | Pages: 342-344

10.1373/clinchem.2009.136218 | PMID 20040616

Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay

Clinical Chemistry | December 3, 2009 | Volume: 56 | Issue: 2 | Pages: 254-261

10.1373/clinchem.2009.132654 | PMID 19959623

Abstract Background: We report the development of a novel high-sensitivity cardiac troponin T (hs-cTnT) assay, a modification of the Roche fourth-generation cTnT assay, and validation of the analytical performance of this assay. Methods: Validation included testing of analytical sensitivity, specificity, interferences, and precision. We established the 99th percentile cutoff from healthy reference populations (n = 616). In addition, we studied differences in time to a positive result when using serial measurements of hs-cTnT vs cTnT in patients with a confirmed diagnosis of non-ST elevation myocardial infarction (non-STEMI). Results: The hs-cTnT assay had an analytical range from 3 to 10 000 ng/L. At the 99th percentile value of 13.5 ng/L, the CV was 9% using the Elecsys® 2010 analyzer. The assay was specific for cTnT without interferences from human cTnI or cTnC, skeletal muscle TnT, or hemoglobin concentrations up to 1000 mg/L, above which falsely lower values would be expected. When the assay was evaluated clinically, a hs-cTnT higher than the 99th percentile concentration identified a significantly higher number of patients with non-STEMI on presentation (45 vs 20 patients, P = 0.0004) compared with cTnT, and a final diagnosis of non-STEMI was made in 9 additional patients (55 vs 46 patients, P = 0.23) after serial sampling. Time to diagnosis was significantly shorter using hs-cTnT compared with cTnT [mean 71.5 (SD 108.7) min vs 246.9 (82.0) min, respectively; P < 0.01]. Conclusions: The analytical performance of hs-cTnT complies with the ESC-ACCF-AHA-WHF Global Task Force recommendations for use in the diagnosis of MI.
Ethical Issues in Cardiovascular Research Involving Humans

Circulation | November 23, 2009 | Volume: 120 | Issue: 21 | Pages: 2113-2121

10.1161/circulationaha.107.752766 | PMID 19933950

Pediatric Brain Natriuretic Peptide Concentrations Vary with Age and Sex and Appear to Be Modulated by Testosterone

Clinical Chemistry | August 14, 2009 | Volume: 55 | Issue: 10 | Pages: 1869-1875

10.1373/clinchem.2009.123778 | PMID 19679633

Abstract Background: Natriuretic peptide concentrations in adults require age- and sex-specific reference intervals for optimal interpretation. Females have higher natriuretic peptide concentrations, and hypotheses suggest that estrogen may be responsible. This study sought to determine the influence of hormone modulation on N-terminal probrain natriuretic peptide (NT-proBNP) by using a pediatric cohort. Children/adolescents typically have rapid hormone changes during puberty, making them an ideal group to study. Methods: We selected 759 specimens (303 male, 456 female; ages 2 months to 18 years, mean 13 years) obtained from the Mayo Clinic Pediatric Residual Specimen Bank. We measured NT-proBNP, sex hormone–binding globulin (SHBG), estradiol, and testosterone by immunoassays or LC-MS/MS and calculated free testosterone. We performed univariate and multivariate analyses to investigate the significance of NT-proBNP with each hormone. Results: Reference values demonstrated a sex difference and sequential age differences in females. Univariate modeling of the hormones with NT-proBNP revealed an independent inverse association of NT-proBNP with testosterone, a direct association with SHBG, and no significant association with estradiol. Multivariate modeling confirmed a strong association of testosterone and SHBG with NT-proBNP. Correlation of hormones with NT-proBNP retained greater significance than either age or sex. Conclusions: In pediatric patients, NT-proBNP is independently associated with both testosterone and SHBG hormone concentrations. Measurements of testosterone are inversely associated with NT-proBNP, and estrogens are marginally associated with NT-proBNP in males but not females, suggesting that androgens and not estrogens modulate sex differences notable in natriuretic peptides. Children and adolescents may require an objective assessment of hormones if optimal interpretation of natriuretic peptide concentrations is desired or the concentrations are confounded. .
Short- and Long-Term Risk Stratification Using a Next-Generation, High-Sensitivity Research Cardiac Troponin I (hs-cTnI) Assay in an Emergency Department Chest Pain Population

Clinical Chemistry | August 13, 2009 | Volume: 55 | Issue: 10 | Pages: 1809-1815

10.1373/clinchem.2009.127241 | PMID 19679630

Abstract Background: The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for predicting death/myocardial infarction (MI), both short- and long-term, in an emergency department acute coronary syndrome (ACS) population. Methods: In a cohort of 383 subjects, originally recruited in 1996, presenting to the emergency department with symptoms suggestive of ACS, the heparin plasma obtained at initial presentation was thawed and measured in 2007 with a research hs-cTnI assay. AccuTnI (Beckman Coulter) measurements were made on these same samples in 2003. The population was divided into 4 groups by hs-cTnI: <5.00, 5.00–9.99, 10.00–40.00, and >40.00 ng/L. Kaplan–Meier, Cox proportional hazards, ROC curves, and logistic regression analyses were used to identify which hs-cTnI concentrations were predictive of death/MI within 10 years after presentation. Results: There were significant differences between the hs-cTnI groups for the probability of death/MI up to 10 years after presentation (P < 0.05). At 6 months, patients with hs-cTnI ≥10.00 ng/L were at higher risk for death/MI (hazard ratio >3.7; P < 0.05) compared with those having hs-cTnI <5.00 ng/L. ROC curve analysis for death/MI at 30 days with the hs-cTnI assay had an area under the curve of 0.74 (95% CI 0.65–0.82), with logistic models yielding an optimal assay threshold of 12.68 ng/L. Conclusions: This research hs-cTnI assay appears useful for risk stratification for death/MI in an ACS population.
Catecholamine Interference in Enzymatic Creatinine Assays

Clinical Chemistry | July 9, 2009 | Volume: 55 | Issue: 9 | Pages: 1732-1736

10.1373/clinchem.2009.127373 | PMID 19589845

Abstract Background: Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigation into interference of catecholamines with enzymatic methods. Methods: Spiked solutions of dopamine, dobutamine, epinephrine, and norepinephrine were added to pooled sera at catecholamine concentrations consistent with clinically relevant dosing. Creatinine was measured enzymatically on the Roche P-Modular, Ortho Clinical Diagnostics Vitros 350, and Abbott i-STAT. Jaffe methods were performed on the Roche P-Modular and Siemens Dimension RxL. In 10 patients receiving dopamine and/or dobutamine via a venous or arterial line we evaluated and compared the extent of in vivo creatinine interference in paired serum samples obtained by venipuncture and from indwelling catheters. Results: All catecholamines caused significant negative interference with the Roche enzymatic creatinine assay, most pronounced for dopamine and dobutamine. The Vitros enzymatic assay demonstrated slight negative interferences, and i-STAT enzymatic and Jaffe methods were unaffected by the presence of catecholamines. Significant (P < 0.001) differences in creatinine concentrations by Roche enzymatic vs Jaffe methods were observed in venipuncture specimens compared with arterial or venous catheter specimens, suggesting dopamine and dobutamine reversibly adhere to the catheter lumen. Conclusions: Negative interferences were pronounced for Roche enzymatic results in blood samples obtained from indwelling catheters, a phenomenon not observed in peripheral draws. Physicians and laboratorians should be alert to the possibility of a falsely low creatinine result and reevaluate questionable samples using a method unaffected by catecholamines.