Citations 62

Injectable conductive hydrogel restores conduction through ablated myocardium

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 | PMID 32966655

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
A novel engineered purified exosome product patch for tendon healing: An explant in an ex vivo model

Journal of Orthopaedic Research | September 16, 2020 | Volume: 39 | Issue: 8 | Pages: 1825-1837

10.1002/jor.24859 | PMID 32936480

AbstractReducing tendon failure after repair remains a challenge due to its poor intrinsic healing ability. The purpose of this study is to investigate the effect of a novel tissue‐engineered purified exosome product (PEP) patch on tendon healing in a canine ex vivo model. Lacerated flexor digitorum profundus (FDP) tendons from three canines' paws underwent simulated repair with Tisseel patch alone or biopotentiated with PEP. For the ex vivo model, FDP tendons were randomly divided into three groups: FDP tendon repair alone group (Control), Tisseel patch alone group, and the Tisseel plus PEP (TEPEP) patch group. Following 4 weeks of tissue culture, the failure load, stiffness, histology, and gene expression of the healing tendon were evaluated. Transmission electron microscopy revealed that in exosomes of PEP the diameters ranged from 93.70 to 124.65 nm, and the patch release test showed this TEPEP patch could stably release the extracellular vesicle over 2 weeks. The failure strength of the tendon in the TEPEP patch group was significantly higher than that of the Control group and Tisseel alone group. The results of histology showed that the TEPEP patch group had the smallest healing gap and the largest number of fibroblasts on the surface of the injured tendon. Quantitative reverse transcription polymerase chain reaction showed that TEPEP patch increased the expression of collagen type III, matrix metallopeptidase 2 (MMP2), MMP3, MMP14, and reduced the expression of transforming growth factor β1, interleukin 6. This study shows that the TEPEP patch could promote tendon repair by reducing gap formation and inflammatory response, increasing the activity of endogenous cells, and formation of type III collagen.
Percutaneous Axillary Intra-aortic Balloon Pump Insertion Technique as Bridge to Advanced Heart Failure Therapy

ASAIO Journal | September 6, 2020 | Volume: 67 | Issue: 4 | Pages: e81-e85

10.1097/mat.0000000000001259 | PMID 33770002

In patients with advanced heart failure (HF), temporary mechanical circulator support (TMCS) is used to improve hemodynamics, via left ventricular unloading, and end-organ function as a bridge to definitive therapy. While listed for cardiac transplantation, use of TMCS may be prolonged, preventing adequate mobility. Here, we describe the technique for placement of a percutaneous axillary intra-aortic balloon pump (IABP) using single-site arterial access to facilitate ambulation and subsequent safe removal without surgery or a closure device. Retrospective review of the experience with this approach at a single institution between September 2017 and February 2020 documented feasibility and safety. Baseline demographics, hemodynamic data, and clinical outcomes were collected. Thirty-eight patients had a total of 56 IABPs placed. There were no significant access site or cerebrovascular complications. One fifth of IABPs (21.4%) had balloon failure or migration, requiring placement of a new device, though no patients had significant complications from balloon failure. The majority (81.6%) of patients in the cohort on axillary IABP support were ambulatory and ultimately received the intended therapy (63.2% transplant, 13.2% durable left ventricular assist device, 5.3% other cardiac surgery). Percutaneous, axillary IABP is feasible and associated with an acceptable complication rate as a bridge to definitive therapy.
Inadequate left ventricular unloading during ramp is associated with hospitalization or death during left ventricular assist device support

Artificial Organs | August 6, 2020 | Volume: 45 | Issue: 2 | Pages: 115-123

10.1111/aor.13792 | PMID 32761951

AbstractA combined right and left‐sided heart catheterization (RHC/LHC) protocol was recently reported to optimize patients supported by left ventricular assist device (LVAD). Using this platform, we sought to evaluate the prognostic significance of several hemodynamic indices, including left ventricular end‐diastolic pressure (LVEDP) and transaortic gradient (peak aortic pressure ‐ peak left ventricular pressure in systole, TAG). We evaluated all patients undergoing RHC/LHC at our institution from 2015 through 2018, and comprehensive clinical data were obtained. Primary end points were (1) a composite outcome that included hospitalization or death and (2) 1‐year overall survival after catheterization. Forty‐two patients were included in the analysis. Optimization resulted in normalization of hemodynamic parameters; all variables were significantly improved from baseline (P ≤ .05). On univariate modeling, final LVEDP was associated with the primary end point (hazard ratio [HR], 1.2 per 1‐mm Hg increase; 95% CI, 1.1‐1.3; P = .002). After adjusting for LVAD speed, TAG, and cardiac index in a multivariate model, the association between LVEDP and the composite end point remained significant (HR, 1.2 per 1‐mm Hg increase; 95% CI, 1.1‐1.4; P = .001). In the setting of LVAD support, inadequate LV unloading was a significant marker of poor outcomes with time, suggesting that LVEDP is a central prognostic marker in this population.
Outcomes of Ambulatory Heart Failure Patients Managed With an Intra-aortic Balloon Pump Before Left Ventricular Assist Device Implantation

ASAIO Journal | August 6, 2020 | Volume: 67 | Issue: 4 | Pages: 430-435

10.1097/mat.0000000000001249 | PMID 33769998

Patients are admitted to the hospital for hemodynamic optimization before left ventricular assist device (LVAD) implantation. The aim of this study was to evaluate the clinical outcomes of hemodynamic optimization using an intra-aortic balloon pump (IABP) in ambulatory heart failure patients before LVAD placement. This retrospective single-center study included 199 noninotrope-dependent patients who underwent durable LVAD implantation between January 1, 2007 and April 10, 2017. Invasive hemodynamic as well as the primary composite end-point of stage 2 or 3 acute kidney injury, right ventricular failure, and 30-day mortality were compared between patients with and without an IABP. Median age was 64 (interquartile range [IQR], 57–71) years and 165 (82.9%) were male; 72 (36.2%) received an IABP. Patients treated with an IABP had worse baseline exercise capacity and hemodynamic parameters. Patients with an IABP had greater relative reduction in pulmonary artery mean pressure (−16% vs. −2%; p ≤ 0.001). The primary composite end-point was not different between patients who had an IABP and those who did not (20.8% vs. 20.5%; p = 0.952), as were each of the individual end-points. Despite worse baseline hemodynamic parameters and exercise capacity, ambulatory heart failure patients who received an IABP before LVAD implantation had more favorable reductions in pulmonary artery pressures without an increase in the composite end-point. These results suggest that IABP use before LVAD implantation may mitigate the risk of postoperative complications in ambulatory patients.
Correction of High Afterload Improves Low Cardiac Output in Patients Supported on Left Ventricular Assist Device Therapy

ASAIO Journal | March 30, 2020 | Volume: 67 | Issue: 1 | Pages: 32-38

10.1097/mat.0000000000001159 | PMID 32224784

There is a paucity of data describing the invasive assessment of afterload and influence on cardiac output in patients supported on left ventricular assist device (LVAD) therapy. From 2015 to 2018, patients on LVAD therapy were evaluated with simultaneous left/right heart catheterization ramp study for speed optimization. Hemodynamic parameters from 31 patients without significant aortic insufficiency were analyzed. Mean central aortic pressure (MAP) was elevated at 87 ± 13 mm Hg at baseline. No direct association between MAP and cardiac index (CI) was found (r = 0.11, p = 0.20). However, variable MAP provided vastly different patterns of cardiac output response to speed increments (positive correlation, p = 0.047 for MAP <80 mm Hg; negative trend, p = 0.25 for MAP > 100 mm Hg). Patients noted to be hypertensive (MAP > 90, n = 8) received nitrate therapy and experienced both improvement in biventricular filling pressures and a mean increase in CI from 2.4 to 2.9 L/min/m2 (+22%, p = 0.04) at a fixed revolutions per minute. High afterload is common in patients on LVAD therapy, is associated with poor response to ramp, and is ameliorated by nitrates. These findings serve as a foundation to evaluate the dynamic effects of high afterload and chronic vasodilator therapy in patients with durable LVADs.
Dual RVAD-ECMO Circuits to Treat Cardiogenic Shock and Hypoxemia Due to Necrotizing Lung Infection: A Case Report

A&A Practice | March 24, 2020 | Volume: 14 | Issue: 6 | Pages: e01181

10.1213/xaa.0000000000001181 | PMID 32224696

Utilization of venoarterial extracorporeal membrane oxygenation (VA-ECMO) is expanding, but dual VA-ECMO circuits to treat cardiogenic shock with refractory hypoxemia is unreported. We describe the case of combined cardiogenic and distributive shock due to necrotizing pulmonary blastomycosis. After initial central VA-ECMO cannulation, acute respiratory distress syndrome (ARDS) with increasing shunt resulted in significant central hypoxemia due to progressive ventilation-perfusion mismatch. An additional circuit provided complete oxygenation of the high circulating volume. After 4 months on support, he underwent successful heart-lung-kidney transplantation. Dual ECMO circuits are technically feasible and may be advantageous in specific circumstances of high pulmonary shunting resulting in excessive hypoxemia unbalanced with appropriate oxygen delivery.
Characterization of a purified exosome product and its effects on canine flexor tenocyte biology

Journal of Orthopaedic Research | January 13, 2020 | Volume: 38 | Issue: 8 | Pages: 1845-1855

10.1002/jor.24587 | PMID 31930553

AbstractFlexor tendon injuries and tendinopathy are very common but remain challenging in clinical treatment. Exosomes‐based cell‐free therapy appears to be a promising strategy for tendon healing, while limited studies have evaluated its impacts on tenocyte biology. The objective of this study was to characterize a novel purified exosome product (PEP) derived from plasma, as well as to explore its cellular effects on canine tenocyte biology. The transmission electron microscope revealed that exosomes of PEP present cup‐shaped structures with the diameters ranged from 80 to 141 nm, and the NanoSight report presented that their size mainly concentrated around 100 nm. The enzyme‐linked immunosorbent assay kits analysis showed that PEP was positive for CD63 and AChE expression, and the cellular uptake of exosomes internalized into tenocyte cytoplasm was observed. The cell growth assays displayed that tenocyte proliferation ability was enhanced by PEP solution in a dose‐dependent manner. Tenogenic phenotype was preserved as is evident by that tendon‐related genes expression (SCX, COL1A, COL3A1, TNMD, DCN, and MKX) were expressed insistently in a high level, while tenocytes were treated with 5% PEP solution. Furthermore, migration capability was maintained and total collagen deposition was increased. More interesting, dexamethasone‐induced cellular apoptosis was attenuated during the incubation of tenocytes with a 5% PEP solution. These findings will provide the basic understandings about the PEP, and support the potential use of this biological strategy for tendon healing.
Predictors and Clinical Outcomes of Vasoplegia in Patients Bridged to Heart Transplantation With Continuous‐Flow Left Ventricular Assist Devices

Journal of the American Heart Association | November 8, 2019 | Volume: 8 | Issue: 22 | Pages: No page available

10.1161/jaha.119.013108 | PMID 31701791

Background The presence of a durable left ventricular assist device ( LVAD ) is associated with increased risk of vasoplegia in the early postoperative period following heart transplantation ( HT ). However, preoperative predictors of vasoplegia and its impact on survival after HT are unknown. We sought to examine predictors and outcomes of patients who develop vasoplegia after HT following bridging therapy with an LVAD . Methods and Results We identified 94 patients who underwent HT after bridging with continuous‐flow LVAD from 2008 to 2018 at a single institution. Vasoplegia was defined as persistent low vascular resistance requiring ≥2 intravenous vasopressors within 48 hours after HT for >24 hours to maintain mean arterial pressure >70 mm Hg. Overall, 44 patients (46.8%) developed vasoplegia after HT . Patients with and without vasoplegia had similar preoperative LVAD , echocardiographic, and hemodynamic parameters. Patients with vasoplegia were significantly older; had longer LVAD support, higher preoperative creatinine, longer cardiopulmonary bypass time, and higher Charlson comorbidity index; and more often underwent combined organ transplantation. In a multivariate logistic regression model, older age (odds ratio: 1.08 per year; P =0.010), longer LVAD support (odds ratio: 1.06 per month; P =0.007), higher creatinine (odds ratio: 3.9 per 1 mg/dL; P =0.039), and longer cardiopulmonary bypass time (odds ratio: 1.83 per hour; P =0.044) were independent predictors of vasoplegia. After mean follow‐up of 4.0 years after HT , vasoplegia was associated with increased risk of all‐cause mortality (hazard ratio: 5.20; 95% CI, 1.71–19.28; P =0.003). Conclusions Older age, longer LVAD support, impaired renal function, and prolonged intraoperative CPB time are independent predictors of vasoplegia in patients undergoing HT after LVAD bridging. Vasoplegia is associated with worse prognosis; therefore, detailed assessment of these predictors can be clinically important.
Exercise-induced hypoxemia predicts heart failure hospitalization and death in patients supported with left ventricular assist devices

The International Journal of Artificial Organs | October 19, 2019 | Volume: 43 | Issue: 3 | Pages: 165-172

10.1177/0391398819882435 | PMID 31630619

Following implantation of continuous-flow left ventricular assist devices, mechanical off-loading results in improved resting hemodynamics; however, peak exercise capacity generally does not increase substantially. This study evaluated patients supported by continuous-flow left ventricular assist devices who were invasively monitored during exercise to define parameters that underpin exercise capacity and outcomes. A review of all patients supported by continuous-flow left ventricular assist devices who underwent supine bicycle ergometry exercise testing with measurement of pulmonary gas exchange during right heart catheterization for evaluation of dyspnea at one institution between 2007 and 2018 was performed (n = 22). The primary outcome of this investigation was death or heart failure hospitalization. Although resting filling pressures were relatively preserved, resting cardiac index (Fick) was low (2.1 ± 0.5 mL/kg/min). An impaired cardiac output reserve was present in 75% of patients. On univariate modeling, patients with supine exercise–induced hypoxemia (O 2 saturation <90%) experienced significantly diminished hospitalization-free survival (unadjusted hazard ratio = 11.0, confidence interval = 2.4–57.2, p = 0.003), which persisted despite adjustment for right heart catheterization peak VO 2 and peak cardiac output (adjusted hazard ratio = 25, confidence interval = 3.6–322, p = 0.001). Our findings suggest that supine exercise testing provides additional prognostic utility in the continuous-flow left ventricular assist device population.